scholarly journals A Novel, Hybrid-Integrated, High-Precision, Vacuum Microelectronic Accelerometer with Nano-Field Emission Tips

Micromachines ◽  
2018 ◽  
Vol 9 (10) ◽  
pp. 481 ◽  
Author(s):  
Haitao Liu ◽  
Kai Wei ◽  
Zhengzhou Li ◽  
Wengang Huang ◽  
Yi Xu ◽  
...  

In this paper, a novel, hybrid-integrated, high-precision, vacuum microelectronic accelerometer is put forward, based on the theory of field emission; the accelerometer consists of a sensitive structure and an ASIC interface (application-specific integrated circuit). The sensitive structure has a cathode cone tip array, a folded beam, an emitter electrode, and a feedback electrode. The sensor is fabricated on a double-sided polished (1 0 0) N-type silicon wafer; the tip array of the cathode is shaped by wet etching with HNA (HNO3, HF, and CH3COOH) and metalized by TiW/Au thin film. The structure of the sensor is finally released by the ICP (inductively coupled plasma) process. The ASIC interface was designed and fabricated based on the P-JFET (Positive-Junction Field Effect Transistor) high-voltage bipolar process. The accelerometer was tested through a static field rollover test, and the test results show that the hybrid-integrated vacuum microelectronic accelerometer has good performance, with a sensitivity of 3.081 V/g, the non-linearity is 0.84% in the measuring range of −1 g~1 g, the average noise spectrum density value is 36.7 μV/ Hz in the frequency range of 0–200 Hz, the resolution of the vacuum microelectronic accelerometer can reach 1.1 × 10−5 g, and the zero stability reaches 0.18 mg in 24 h.

Author(s):  
Haitao Liu ◽  
Zhiyu Wen ◽  
Wengang Huang ◽  
Donglin Li ◽  
Li Chen ◽  
...  

In this paper, a novel integrated high precision vacuum microelectronic accelerometer is put forward based on the theory of field emission, the accelerometer consists of sensitive structure and interface ASIC. The sensitive structure has a mass of a cathode cone tips array, a folded beam, an emitter electrode and a feedback electrode. The sensor is fabricated on a double side polished (1 0 0) N-type silicon wafer, the tips array of cathode are shaped by wet etching with HNA (HNO3, HF and CH3COOH) and metalized by TiW/Au thin film. The structure of sensor is released by ICP process finally. The interface ASIC was designed and fabricated based on the P-JFET high voltage bipolar process. The accelerometer is tested through static field rollover test, and the test results show the integrated vacuum microelectronic accelerometer has good performances, which sensitivity is 3.081V/g and non-linearity is 0.84% in the measuring range of −1g~1g.


Author(s):  
Kaiyun Chen ◽  
Zhian Bao ◽  
Honglin Yuan ◽  
Nan Lv

This study presents a practical method for high-precision Fe isotope determination without column chromatography purification for iron-dominated mineral samples using multi-collector inductively coupled plasma-mass spectrometry (MC-ICP-MS). A series of comparable...


2021 ◽  
Author(s):  
Qingqing Zhao ◽  
Degao Zhai ◽  
Ryan Mathur ◽  
Jiajun Liu ◽  
David Selby ◽  
...  

Abstract Whether giant porphyry ore deposits are the products of single, short-lived magmatic-hydrothermal events or multiple events over a prolonged interval is a topic of considerable debate. Previous studies, however, have all been devoted to porphyry Cu and Cu-Mo deposits. In this paper, we report high-precision isotope dilution-negative-thermal ionization mass spectrometric (ID-N-TIMS) molybdenite Re-Os ages for the newly discovered, world-class Chalukou porphyry Mo deposit (reserves of 2.46 Mt @ 0.087 wt % Mo) in NE China. Samples were selected based on a careful evaluation of the relative timing of the different vein types (i.e., A, B, and D veins), thereby ensuring that the suite of samples analyzed could be used to reliably determine the age and duration of mineralization. The molybdenite Re-Os geochronology reveals that hydrothermal activity at Chalukou involved two magmatic-hydrothermal events spanning an interval of 6.92 ± 0.16 m.y. The first event (153.96 ± 0.08/0.63/0.79 Ma, molybdenite ID-N-TIMS Re-Os age) was associated with the emplacement of a granite porphyry dated at 152.1 ± 2.2 Ma (zircon laser ablation-inductively coupled plasma-microscopic [LA-ICP-MS] U-Pb ages), and led to only minor Mo mineralization, accounting for <10% of the overall Mo budget. The bulk of the Mo (>90%) was deposited in less than 650 kyr, between 147.67 ± 0.10/0.60/0.76 and 147.04 ± 0.12/0.72/0.86 Ma (molybdenite ID-N-TIMS Re-Os ages), coincident with the emplacement of a fine-grained porphyry at 148.1 ± 2.6 Ma (zircon LA-ICP-MS U-Pb ages). The high-precision Re-Os age determinations presented here show, contrary to the finding of a number of studies of porphyry Cu and Cu-Mo systems, that the giant Chalukou porphyry Mo deposit primarily formed in a single, short-lived (<650 kyr) hydrothermal event, suggesting that this may also have been the case for other giant porphyry Mo deposits.


Author(s):  
Hai-Ou Gu ◽  
Sun He

This study presents a method for high-precision stable potassium (K) isotope analysis using Multi-Collector Inductively Coupled Plasma Mass Spectrometry (MC-ICPMS) without collision cell in low resolution mode. Cold plasma technique...


Sign in / Sign up

Export Citation Format

Share Document