scholarly journals Fracture Load of CAD/CAM Fabricated Cantilever Implant-Supported Zirconia Framework: An In Vitro Study

Molecules ◽  
2021 ◽  
Vol 26 (8) ◽  
pp. 2259
Author(s):  
Ibraheem F. Alshiddi ◽  
Syed Rashid Habib ◽  
Muhammad Sohail Zafar ◽  
Salwa Bajunaid ◽  
Nawaf Labban ◽  
...  

The fracture resistance of computer-aided designing and computer-aided manufacturing CAD/CAM fabricated implant-supported cantilever zirconia frameworks (ISCZFs) is affected by the size/dimension and the micro cracks produced from diamond burs during the milling process. The present in vitro study investigated the fracture load for different cross-sectional dimensions of connector sites of implant-supported cantilever zirconia frameworks (ISCZFs) with different cantilever lengths (load point). A total of 48 ISCZFs (Cercon, Degudent; Dentsply, Deutschland, Germany) were fabricated by CAD/CAM and divided into four groups based on cantilever length and reinforcement of distal-abutment: Group A: 9 mm cantilever; Group B: 9 mm cantilever with reinforced distal-abutment; Group C: 12 mm cantilever; Group D: 12 mm cantilever with reinforced distal-abutment (n = 12). The ISCZFs were loaded using a universal testing machine for recording the fracture load. Descriptive statistics, ANOVA, and Tukey’s test were used for the statistical analysis (p < 0.05). Significant variations were found between the fracture loads of the four ISCZFs (p = 0.000); Group-C and B were found with the weakest and the strongest distal cantilever frameworks with fracture load of 670.39 ± 130.96 N and 1137.86 ± 127.85 N, respectively. The mean difference of the fracture load between groups A (810.49 + 137.579 N) and B (1137.86 ± 127.85 N) and between C (670.39 ± 130.96 N) and D (914.58 + 149.635 N) was statistically significant (p = 0.000). Significant variations in the fracture load between the ISCZFs with different cantilever lengths and thicknesses of the distal abutments were found. Increasing the thickness of the distal abutment only by 0.5 mm reinforces the distal abutments by significantly increasing the fracture load of the ISCZFs. Therefore, an increase in the thickness of the distal abutments is recommended in patients seeking implant-supported distal cantilever fixed prostheses.

Materials ◽  
2020 ◽  
Vol 13 (19) ◽  
pp. 4239
Author(s):  
Roxana-Diana Vasiliu ◽  
Sorin Daniel Porojan ◽  
Liliana Porojan

The accuracy of newly developed ceramic materials is still being studied. Marginal and internal adaptation are known factors that have an essential impact on the long term success of dental restorations. The aim of this in vitro study was to evaluate the marginal and internal fit of heat-pressed and milled monolithic glass-ceramic restorations based on their ceramic type, processing technique, and in vitro thermocycling. Thirty-two crowns were studied and divided into four groups (n = 8), according to the ceramic material (feldspathic glass-ceramic (F) and zirconia reinforced lithium silicate glass-ceramic (ZLS)) and to their technological obtaining processes (milling (M) and heat-pressing (P)). A typodont preparation was scanned with a D2000 3D scanner to obtain identical 32 resin 3D-printed abutment teeth. Marginal and internal gaps were measured using the silicone replica technique under 40× magnification. The crowns were further cemented and thermally aged for 10,000 cycles After cementation and thermocycling of the samples, marginal and internal gaps were assessed using micro-CT (micro-computed tomography)) analysis. Data were statistically analyzed using statistical tests. Significant differences were found before and after cementation and thermocycling among the tested materials (p < 0.05). Related to technological processing, significant differences were seen in the marginal area between FP and FM (p < 0.05) Significant differences were also found in the axial and occlusal areas between the ZLSP and ZLSM. Thermocycling and cementation did not have a significant effect on the tested materials (p < 0.05). The technological processes influenced the marginal and internal fit of the crowns in favor of the CAD/CAM (computer aided design/computer aided manufacturing)technologies. Thermal aging had little effect on marginal adaptability; it increased the values for all the tested samples in a small way, but the values remained in their clinically acceptable range for all of the crowns.


2014 ◽  
Vol 39 (3) ◽  
pp. 308-316 ◽  
Author(s):  
P Tidehag ◽  
K Ottosson ◽  
G Sjögren

SUMMARY The present in vitro study concerns determination of the pre-cementation gap width of all-ceramic crowns made using an in-office digital-impression technique and subsequent computer-aided design/computer-aided manufacturing (CAD/CAM) production. Two chairside video camera systems were used: the Lava Oral scanner and Cadent's iTero scanner. Digital scans were made of a first molar typodont tooth that was suitably prepared for an all-ceramic crown. The digital impressions were sent via the Internet to commercial dental laboratories, where the crowns were made. Also, an impression of the typodont tooth was made, poured, and scanned in order to evaluate the pre-cementation gap of crowns produced from scanning stone dies. These methods and systems were evaluated by creating replicas of the intermediate space using an addition-cured silicone, and the gap widths were determined using a measuring microscope. Hot-pressed leucite-reinforced glass-ceramic crowns were selected as a reference. The mean value for the marginal measuring points of the control was 170 μm, and the values for all the evaluated crowns ranged from 107 to 128 μm. Corresponding figures for the internal measuring points were 141-210 μm and 115-237 μm, respectively. Based on the findings in the present study, an in-office digital-impression technique can be used to fabricate CAD/CAM ceramic single crowns with a marginal and internal accuracy that is on the same level as that of a conventional hot-pressed glass-ceramic crown. In the present study, however, slight differences could be seen between the two types of ceramic crowns studied with respect to the internal fit obtained.


2020 ◽  
pp. 232020682097597
Author(s):  
Ece Irem Oguz ◽  
Mehmet Ali Kılıçarslan ◽  
Merve Erdog˘ Özgür ◽  
Kaan Orhan ◽  
Sohaib Shujaat

Aim: To compare the marginal adaptation of crowns fabricated by using three different resin-ceramic computer-aided design/computer-aided manufacturing (CAD/CAM) materials. Materials and Methods: Crowns fabricated from three different resin-ceramic CAD/CAM blocks, applied on a typodont premolar (#14), were tested with regard to marginal adaptation, in this in vitro study. The typodont maxillary first premolar was prepared to serve as the master die and digitized with an intraoral scanner. The same virtual crown design was used to fabricate all specimens. Forty-eight crowns were fabricated from the same virtual crown design using three different CAD/CAM resin-ceramic blocks as follows ( n = 16): Lava Ultimate (LU), GC Cerasmart (GC), Vita Enamic (VE). Master die and crowns were scanned with a laboratory scanner and three-dimensional data were transferred into three-matic software. The software calculated the mean of the marginal discrepancy (MD) for each crown in negative and positive values, representing under and over estimation of the crown margin, respectively. A marginal discrepancy index (MDI) was obtained for each group using negative and positive MDs. All data were statistically analyzed using one-way analysis of variance and Tukey’s honest significance test ( α = 0.05). Results: The analysis of variance showed no statistical differences between materials regarding the negative and positive MDs ( P > .05). The MDI for LU was lower than GC and VE ( P < .05). Conclusion: The marginal adaptation of different resin-ceramic materials was different with regard to MDI values. Nevertheless, the MD values of all groups were within the clinically acceptable range.


2018 ◽  
Vol 55 (3) ◽  
pp. 361-363
Author(s):  
Daniel Alexandru Pop ◽  
R. Malaescu ◽  
Liviu Marsavina ◽  
Tiberiu Hosszu ◽  
Raul Rotar ◽  
...  

The aim of this in vitro study is to compare the load-to-fracture performance of polymethyl methacrylates (PMMA) provisional restorations manufactured with a traditional laboratory technique in comparison to a computer-assisted design and computer-assisted manufacturing (CAD-CAM) technique. Five interim three-unit fixed dental prostheses were fabricated with the conventional indirect technique, on a standard typodont. The same model was scanned with an intraoral scanner and the digital design of identical fixed dental prostheses was made. Then other five interim three-unit fixed dental prostheses were milled from PMMA CAD/CAM blocks with an in office milling machine. All specimens were tested for flexural strength in a universal testing machine, and the maximum load to fracture was measured. For the conventional provisional restorations, the load to fracture was 121.16 � 24.6, in comparison to CAD/CAM interim restorations, for which the load to fracture was 728.88 � 228.7. Within the limitations of this study, one can conclude that CAD/CAM provisional restorations present a higher fracture load than the conventional manufactured interim restorations.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Ahmed Othman ◽  
Steven Hartman ◽  
Dragan Ströbele ◽  
Jassin Arnold ◽  
von See

Abstract Background The purpose of the presented investigation is to evaluate the resulting torque on loaded 3D printed springs using different coil thickness and length. Methods Specimens were designed and printed using the 3D printer MAX (Asiga, Sydney, Australia) with 3D printable, experimental, flexible material (Code:BM2008, GC, Tokyo, Japan). The specimens were divided into three groups according to spring coil design. Control group (n = 18), length group (n = 19) and thickness group (n = 22). Groups were tested using a Sauter Machine for torque calculation (DB, Grindelwald, Switzerland) in conjunction with a universal testing machine (Zwick Z010, Ulm, Germany) for clock-wise and anti-clockwise testing. Statistical analysis was performed using the Steel–Dwass test to compare median values of the three groups in both testing directions (p < 0.001). Results The highest torque value was determined in the thickness group for both clockwise and anti-clockwise testing directions, achieving 44.00 N/mm and 39.62 N/mm respectively. The length group ranged from 21.65 to 11.04 N/mm in clockwise direction and from 18.04 to 11.38 N/mm in counter-clockwise testing. The control group ranged from 22.72 to 17.18 N/mm in the clock-wise direction while in the anti-clock wise testing it ranged from 21.34 to 16.02 N/mm. Conclusions The amount of torque produced from the computer aided designing/computer aided manufacturing (CAD/CAM) springs is being affected by diameter more than the length design parameter in comparison to the control group. The values of the thickness group are significantly higher than those of the length group (P < 0.001).


Materials ◽  
2021 ◽  
Vol 14 (4) ◽  
pp. 959
Author(s):  
Verónica Rodríguez ◽  
Celia Tobar ◽  
Carlos López-Suárez ◽  
Jesús Peláez ◽  
María J. Suárez

The aim of this study was to investigate the load to fracture and fracture pattern of prosthetic frameworks for tooth-supported fixed partial dentures (FPDs) fabricated with different subtractive computer-aided design and computer-aided manufacturing (CAD-CAM) materials. Materials and Methods: Thirty standardized specimens with two abutments were fabricated to receive three-unit posterior FDP frameworks with an intermediate pontic. Specimens were randomly divided into three groups (n = 10 each) according to the material: group 1 (MM)—milled metal; group 2 (L)—zirconia; and group 3 (P)—Polyetheretherketone (PEEK). The specimens were thermo-cycled and subjected to a three-point bending test until fracture using a universal testing machine (cross-head speed: 1 mm/min). Axial compressive loads were applied at the central fossa of the pontics. Data analysis was made using one-way analysis of variance, Tamhane post hoc test, and Weibull statistics (α = 0.05). Results: Significant differences were observed among the groups for the fracture load (p < 0.0001). MM frameworks showed the highest fracture load values. The PEEK group registered higher fracture load values than zirconia samples. The Weibull statistics corroborated these results. The fracture pattern was different among the groups. Conclusions: Milled metal provided the highest fracture load values, followed by PEEK, and zirconia. However, all tested groups demonstrated clinically acceptable fracture load values higher than 1000 N. PEEK might be considered a promising alternative for posterior FPDs.


2021 ◽  
Vol 11 (2) ◽  
pp. 857
Author(s):  
Keunbada Son ◽  
Kyu-Bok Lee

The purpose of this in vitro study was to evaluate marginal and internal fits of ceramic crowns fabricated with chairside computer-aided design and manufacturing (CAD/CAM) systems. An experimental model based on ISO 12836:2015 was digitally scanned with different intraoral scanners (Omnicam (CEREC), EZIS PO (DDS), and CS3500 (Carestream)). Ceramic crowns were fabricated using the CAD/CAM process recommended by each system (CEREC, EZIS, and Carestream systems; N = 15). The 3-dimensional (3D) marginal and internal fit of each ceramic crown was measured using a 3D inspection software (Geomagic control X). Differences among the systems and various measurements were evaluated using the Kruskal–Wallis test. Statistically significant differences were validated using pairwise comparisons (α = 0.05). Occlusal gaps in the CEREC, EZIS, and Carestream groups were 113.0, 161.3, and 438.2 µm, respectively (p < 0.001). The axial gaps were 83.4, 78.0, and 107.9 µm, respectively. The marginal gaps were 77.8, 99.3, and 60.6 µm, respectively, and the whole gaps were 85.9, 107.3, and 214.0 µm, respectively. Significant differences were observed with the EZIS system compared with the other two systems in terms of the marginal gap sizes. The CEREC system showed no significant differences among the four measured regions. However, the EZIS and Carestream systems did show a statistically significant difference (p < 0.05). All three systems were judged to be capable of fabricating clinically acceptable prostheses, because the marginal gap, which is the most important factor in the marginal fit of prostheses, was recorded to be below 100 µm in all three systems.


Author(s):  
A. Olivier ◽  
J. Wannenburg ◽  
R.D. Gottschalk ◽  
M.J. Van der Linde ◽  
H.T. Groeneveld

A shoe was designed to combine the advantages of a reverse shoe and an adjustable heart bar shoe in the treatment of chronic laminitis. This reverse even frog pressure (REFP) shoe applies pressure uniformly over a large area of the frog solar surface. Pressure is applied vertically upward parallel to the solar surface of the frog and can be increased or decreased as required. Five clinically healthy horses were humanely euthanased and their dismem-bered forelimbs used in an in vitro study. Frog pressure was measured by strain gauges applied to the ground surface of the carrying tab portion of the shoe. A linear variable distance transducer (LVDT) was inserted into a hole drilled in the dorsal hoof wall. The LVDT measured movement of the third phalanx (P3) in a dorsopalmar plane relative to the dorsal hoof wall. The vertical component of hoof wall compression was measured by means of unidirectional strain gauges attached to the toe, quarter and heel of the medial hoof wall of each specimen. The entire limb was mounted vertically in a tensile testing machine and submitted to vertical downward compressive forces of 0 to 2500 Nat a rate of 5 cm/minute. The effects of increasing frog pressure on hoof wall weight-bearing and third phalanx movement within the hoof were determined. Each specimen was tested with the shoe under the following conditions: zero frog pressure; frog pressure used to treat clinical cases of chronic laminitis (7 N-cm); frog pressure clinically painful to the horse as determined prior to euthanasia; frog pressure just alleviating this pain. The specimens were also tested after shoe removal. Total weight-bearing on the hoof wall at zero frog pressure was used as the basis for comparison. Pain-causing and pain-alleviating frog pressures decreased total weight-bearing on the hoof wall (P < 0.05). Frog pressure of 7 N-cm had no statistically significant effect on hoof wall weight-bearing although there was a trend for it to decrease as load increased. Before loading, the pain-causing and pain-alleviating frog pressures resulted in a palmar movement of P3 relative to the dorsal hoof wall compared to the position of P3 at zero frog pressure (P < 0.05). This difference remained statistically significant up to 1300 Nload. At higher loads, the position of P3 did not differ significantly for the different frog pressures applied. It is concluded that increased frog pressure using the REFP shoe decreases total hoof wall weight-bearing and causes palmar movement of P3 at low weight-bearing loads. Without a shoe the toe and quarter hoof wall compression remained more constant and less in magnitude, than with a shoe.