scholarly journals Validation of a Simple HPLC-Based Method for Lysine Quantification for Ruminant Nutrition

Molecules ◽  
2021 ◽  
Vol 26 (14) ◽  
pp. 4173
Author(s):  
João Albuquerque ◽  
Susana Casal ◽  
Rebeca Cruz ◽  
Ingrid Van Dorpe ◽  
Margarida Rosa Garcez Maia ◽  
...  

Robust and selective quantification methods are required to better analyze feed supplementation effectiveness with specific amino acids. In this work, a reversed-phase high-performance liquid chromatography method with fluorescence detection is proposed and validated for lysine quantification, one of the most limiting amino acids in ruminant nutrition and essential towards milk production. To assess and widen method applicability, different matrices were considered: namely Li2CO3 buffer (the chosen standard reaction buffer), phosphate buffer solution (to mimic media in cellular studies), and rumen inoculum. The method was validated for all three matrices and found to be selective, accurate (92% ± 2%), and precise at both the inter- and intra-day levels in concentrations up to 225 µM, with detection and quantification limits lower than 1.24 and 4.14 µM, respectively. Sample stability was evaluated when stored at room temperature, 4 °C, and −20 °C, showing consistency for up to 48 h regardless of the matrix. Finally, the developed method was applied in the quantification of lysine on real samples. The results presented indicate that the proposed method can be applied towards free lysine quantification in ruminant feeding studies and potentially be of great benefit to dairy cow nutrition supplementation and optimization.

2014 ◽  
Vol 6 (16) ◽  
pp. 6560-6564 ◽  
Author(s):  
Wuxiang Zhang ◽  
Yicong Su ◽  
Jiangu Shi ◽  
Maosheng Zhang ◽  
Bide Wu ◽  
...  

In this paper, a high performance liquid chromatography technique is established for quantification of paraquat in blood.


INDIAN DRUGS ◽  
2021 ◽  
Vol 57 (10) ◽  
pp. 47-57

An isocratic Reversed-Phase High Performance Liquid Chromatography method has been developed for rapid and simultaneous separation and estimation of two antibiotics, namely, nitazoxanide and ofloxacin, in human plasma. Separation was carried out on Altima C8 (150 x 4.6 mm, 5µ) column using a mobile phase of 0.1% ortho phosphoric acid: acetonitrile (50:50, V/V) at 260 nm. The retention time of nitazoxanide and ofloxacin was noted to be 4.850 and 7.949 min, respectively. The average % recovery for nitazoxanide and ofloxacin were 98.012 % and 94.176 %, respectively and reproducibility was found to be satisfactory. The linearity was investigated in the concentration range of 0.02-2 µg/ml (r2=0.9996) for nitazoxanide and 0.008-0.8 µg/ml (r2=0.9998) for ofloxacin. The lower limits of quantification were 0.0196 µg/ml and 0.0079 µg/ml for nitazoxanide and ofloxacin, respectively, which reach the level of both drugs possibly found in human plasma. The proposed method can be applied for etermination of nitazoxanide and ofloxacin from dosage forms during pharmacokinetic study.


2008 ◽  
Vol 30 (3) ◽  
pp. 341-346 ◽  
Author(s):  
Maria Bernadete Sousa Maia ◽  
Ismael Leite Martins ◽  
Demétrius Fernandes do Nascimento ◽  
Adriano Nunes Cunha ◽  
Francisco Evanir Gonçalves de Lima ◽  
...  

2017 ◽  
Vol 5 ◽  
pp. 1266-1274
Author(s):  
Javor Mitkov ◽  
Maya Georgieva ◽  
Alexander Zlatkov

This study evaluates a series of caffeine-8-thioglycolic acid amides that were synthesized in the study, for signs of possible degradation. The chemical stability of the test compounds was examined under different conditions of pH and temperature over time. A modified reversed phase-high-performance liquid chromatography method was applied to determine stability and identify possible degradation products. The study identified a new product from oxidative destruction of the test compound through controlled synthesis.


Author(s):  
RAMA BUKKA ◽  
CHAYA HN

Objective: The study is aimed to develop a simple, isocratic and sensitive reversed-phase high-performance liquid chromatography method for the analysis of granisetron during transdermal permeation studies through porcine ear epithelium. Methods: A reversed-phase (C18) column was used with ultraviolet detection at 210 nm. Selected mobile phase contained 25% (v/v) of acetonitrile and 75% (v/v) of 0.25 mM potassium dihydrogen orthophosphate solution pH adjusted to 3.0 using 1% orthophosphoric acid solution. Results: Calibration curve showed good linearity over 0.1–30 μg/mL concentration range of porcine ear permeates in 80% ethanol and 20% water (blank permeates). The applicability of the method was demonstrated by the analysis of diffusion study samples of granisetron through porcine ear epithelium and the steady-state permeability flux (J) from ethanolic solution was found to be 4.707 µg/square cm/h. Conclusion: The developed method can be used in the analysis of diffusion study samples of granisetron transdermal formulations through the porcine ear epithelium.


Author(s):  
Mannem Durga Babu ◽  
Kesana Surendrababu

Objective: The objective of the study was to develop and validate a novel, specific, precise, and simple reversed-phase high-performance liquid chromatography method for the estimation of guaifenesin present in methocarbamol API and its pharmaceutical dosage forms. Methods: The baseline separation for methocarbamol and guaifenesin was achieved by utilizing a Inertsil ODS C18 (250 mm × 4.6 mm) 5 μm column particle size and an isocratic elution method. The mobile phase contains a mixture of water and acetonitrile in the ratio of 70:30 v/v, respectively. The flow rate of the mobile phase was 1.0 mL/min with a column temperature of 25°C and detection wavelength at 272 nm. The method was validated for a limit of detection (LOD), limit of quantification (LOQ), linearity, accuracy, and reproducibility with the help of the exhibit and simulated samples. Results: The LOD for guaifenesin was 0.62 μg/mL. The LOQ for guaifenesin was 1.87 μg/mL. The correlation coefficient obtained for impurity was >0.99. The recovery was obtained for impurity was 106.56% at 50%, 95.20% at 100%, and 100.45% at 150%. In tablet analysis, we can found 0.26% (<0.5%). Conclusion: The developed method was validated as per the ICH guidelines with respect to specificity, precision, linearity, accuracy, LOD and quantification, ruggedness, robustness, and solution stability.