For students, who spend most of their time in school classrooms, it is important to maintain indoor air quality (IAQ) to ensure a comfortable and healthy life. Recently, the ventilation performance for indoor air quality in elementary schools has emerged as an important social issue due to the increase in the number of days of continuous high concentrations of particulate matter. Three-dimensional numerical analysis has been introduced to evaluate the indoor airflow according to the installation location of return diffusers. Considering the possibility of the cross-infection of infectious diseases between students due to the direction of airflow in the classroom, the airflow angles of the average respiratory height range of elementary school students, between 1.0 and 1.5 m, are analyzed. Throughout the numerical analysis inside the classroom, it is found that the floor return system reduces the indoor horizontal airflow that causes cross-infection among students by 20% compared to the upper return systems. Air ventilation performance is also analyzed in detail using the results of numerical simulation, including streamlines, temperature and the age of air.

2020 ◽  
Vol 38 (9A) ◽  
pp. 1257-1275
Author(s):  
Wisam M. Mareed ◽  
Hasanen M. Hussen

 Elevated CO2 rates in a building affect the health of the occupant. This paper deals with an experimental and numerical analysis conducted in a full-scale test room located in the Department of Mechanical Engineering at the University of Technology. The experiments and CFD were conducted for analyzing ventilation performance. It is a study on the effect of the discharge airflow rate of the ceiling type air-conditioner on ventilation performance in the lecture room with the mixing ventilation. Most obtained findings show that database and questionnaires analyzed prefer heights between 0.2 m to 1.2 m in the middle of an occupied zone and breathing zone height of between 0.75 m to 1.8 given in the literature surveyed. It is noticed the mismatch of internal conditions with thermal comfort, and indoor air quality recommended by [ASHRAE Standard 62, ANSI / ASHRAE Standard 55-2010]. CFD simulations have been carried to provide insights on the indoor air quality and comfort conditions throughout the classroom. Particle concentrations, thermal conditions, and modified ventilation system solutions are reported.


Sensors ◽  
2018 ◽  
Vol 18 (11) ◽  
pp. 3798 ◽  
Author(s):  
Sara Zanni ◽  
Francesco Lalli ◽  
Eleonora Foschi ◽  
Alessandra Bonoli ◽  
Luca Mantecchini

Indoor air quality (IAQ) management in public spaces is assuming a remarkable importance. Busy environments, like airport terminals, are currently regarded as possible hotspots and IAQ is a crucial element for passengers and staff protection, as well as a key aspect of airport passenger experience. A one-month monitoring period has been performed on IAQ in the airport of Bologna (Italy), as prototypal example of large regional airport. Four strategic areas within the airport have been equipped with electronic monitoring platforms, including different contaminants and two microclimatic sensors. Data suggest that daily variation in IAQ parameters typically follow the activity pattern of the different environments under study (i.e., passengers’ flows) for gaseous contaminants, where particulate matter counts oscillate in a definite range, with a significant role played by ventilation system. Gaseous contaminants show a correlation between indoor and outdoor concentrations, mainly due to airside activities. Micro-climatic comfort parameters have been tested to match with standards for commercial environments. As results appears in line with typical households IAQ values, the current air ventilation system appears to be adequate. Nevertheless, an integrated air management system, based on real-time monitoring, would lead to optimization and improvement in environmental and economical sustainability.


Author(s):  
M. F. Mohamed ◽  
M. Behnia ◽  
S. King ◽  
D. Prasad

Cross ventilation is a more effective ventilation strategy in comparison to single-sided ventilation. In the NSW Residential Flat Design Code1 (RFDC) the majority of apartments are required to adopt cross ventilation. However, in the case of studio and one-bedroom apartments, it is acknowledged that single-sided ventilation may prevail. Deep plan studio and one-bedroom apartments may achieve lower amenity of summer thermal comfort and indoor air quality where mechanical ventilation is not provided by air conditioning. Since compliance with the code may allow up to 40% of apartments in a development in Sydney to be single sided, it is important to understand the natural ventilation performance of such apartments. The objective of this paper is to investigate the natural ventilation potential in single-sided ventilated apartments to improve indoor air quality and thermal comfort. This investigation includes simulating various facade treatments involving multiple opening and balcony configurations. Balcony configurations are included in this study because, in Sydney, a balcony is a compulsory architectural element in any apartment building. The study uses computational fluid dynamics (CFD) software to simulate and predict the ventilation performance of each apartment configuration. This study suggests that properly configured balconies and openings can significantly improve indoor ventilation performance for enhanced indoor air quality and thermal comfort, by optimizing the available prevailing wind. However, it is important to note that inappropriately designed fac¸ade treatments also could diminish natural ventilation performance.


2014 ◽  
Vol 564 ◽  
pp. 250-255
Author(s):  
M.M. Syafiq Syazwan ◽  
Mohammad Zainal M. Yusof ◽  
C.K. Chang ◽  
M.D. Amir Abdullah

Sensible (temperature) and latent (moisture) loads are the common load an air-conditioning (AC) system need to handle. Both loads are generated from conditioned space, internal source and outdoor air ventilation. This study is to monitor the indoor air quality IAQ in hotel restaurant and the results are compared with Malaysian standard MS1525 and Industry Code of Practice (COP) on IAQ 2010, Department of Safety and Health (DOSH) Malaysia. The AC system performance was also monitored to identify the actual cooling energy usage base on standard operations. Psychrometric chart was used to analyse the actual cooling energy required and identified the latent and sensible loads significantly. The result of the study shows the mean air temperature, relative humidity (RH), carbon dioxide (CO) and carbon monoxide (CO2) levels were within range as stipulated by standard and code of practice. Heat loads analysis on a psychrometric chart showed the total cooling energy as 296.2 kW; of which 196.3 kW was contributed to primary air unit (PAU) and 99.9 kW to air handling unit (AHU) respectively. The primary contribution for sensible and latent loads and recommendation of potential energy saving also been discussed to meet energy efficient in AC system while maintaining good indoor air quality in the restaurant.


2019 ◽  
Vol 27 (03) ◽  
pp. 1950028
Author(s):  
Yong-Il Kwon

The modern people are active in various cultural facilities and enjoy the leisure life. The spectators and performers using a small concert hall generally use this space for about 2[Formula: see text]h in an enclosed state, and so the space should maintain a comfortable thermal environment and indoor air quality. The ventilation systems that can be applied to small concert hall are generally classified as the mixing ventilation system and the displacement ventilation system, but the upward displacement ventilation system is known to be able to maintain the clean indoor air quality with high energy efficiency. The upward displacement ventilation system installed in a dome-shaped small concert hall is not limited in the height of the vertical wall. Therefore, it is necessary to evaluate the optimal height of the return diffuser by utilizing the ventilation performance and the air diffusion performance index (ADPI). This study was carried out to evaluate the effect of the return diffuser position on the ventilation performance of an upward displacement ventilation system installed in a dome-shaped small concert hall. It was confirmed that as the height at which the return diffuser is installed on the vertical wall increases, the ventilation efficiency increases and the thermal stratification formed in the upper area is significantly reduced.


2019 ◽  
Vol 12 (6) ◽  
pp. 1141-1159
Author(s):  
Gaëlle Guyot ◽  
Hugo Geoffroy ◽  
Michel Ondarts ◽  
Léna Migne ◽  
Mallory Bobee ◽  
...  

Energies ◽  
2018 ◽  
Vol 11 (10) ◽  
pp. 2536 ◽  
Author(s):  
Payam Nejat ◽  
Fatemeh Jomehzadeh ◽  
Hasanen Hussen ◽  
John Calautit ◽  
Muhd Abd Majid

Generally, two-third of a building’s energy is consumed by heating, ventilation and air-conditioning systems. One green alternative for conventional air conditioner systems is the implementation of passive cooling. Wing walls and windcatchers are two prominent passive cooling techniques which use wind as a renewable resource for cooling. However, in low wind speed regions and climates, the utilization of natural ventilation systems is accompanied by serious uncertainties. The performance of ventilation systems can be potentially enhanced by integrating windcatchers with wing walls. Since previous studies have not considered this integration, in the first part of this research the effect of this integration on the ventilation performance was assessed and the optimum angle was revealed. However, there is still gap of this combination; thus, in the second part, the impact of wing wall length on the indoor air quality factors was evaluated. This research implemented a Computational Fluid Dynamics (CFD) method to address the gap. The CFD simulation was successfully validated with experimental data from wind tunnel tests related to the previous part. Ten different lengths from 10 cm to 100 cm were analyzed and it was found that the increase in wing wall length leads to a gradual reduction in ventilation performance. Hence, the length does not have a considerable influence on the indoor air quality factors. However, the best performance was seen in 10 cm, that could provide 0.8 m/s for supply air velocity, 790 L/s for air flow rate, 39.5 1/h for air change rate, 107 s for mean age of air and 92% for air change effectiveness.