scholarly journals Current Status of Aged Public Buildings and Effect Analysis Prediction of Green Remodeling in South Korea

2021 ◽  
Vol 13 (12) ◽  
pp. 6649
Author(s):  
Seunghoon Nam ◽  
Jaemoon Kim ◽  
Duwhan Lee

The purpose of this study is to analyze the scope of the expected improvement effect of office buildings and educational research facilities according to green remodeling. Thus, in order to quantitatively grasp the architectural performance of the existing buildings, the building thermal performance, the airtightness, the indoor environment, and the air quality were measured using equipment. The analysis indicated that the envelope performance and the indoor environment were unsatisfactory compared to the current legal standards, and for indoor air quality, CO2 and formaldehyde were measured to be dissatisfactory in some buildings. The energy analysis results indicated that the improvement range differed according to the renovation history for each building, resulting in differences in the energy-saving rate for each alternative. The reduction rates of primary energy consumption using energy simulation were 38.5–67.4% for office buildings and 23.7–66.3% for educational research facilities, and the payback periods were 14 to 27 years for office buildings and 12 to 30 years for educational research facilities. These results are expected to contribute to the activation of green remodeling because they can be used as indicators to predict the expected construction cost, the payback period, and the expected effect required for green remodeling.

Author(s):  
Ramiz Kameel ◽  
Essam E. Khalil

To design an optimum HVAC airside system that provides comfort and air quality in the air-conditioned spaces with efficient energy consumption is a great challenge. This paper evaluates recent progresses of HVAC airside design for the airconditioned spaces. The present evaluation study defines the current status, future requirements, and expectations. It has been found that, the experimental investigations should be considered in the new trend of studies, not to validate the numerical tools only, but also to provide a complete database of the airflow characteristics in the air-conditioned spaces. Based on this analysis and the vast progress of computers and associated software, the artificial intelligent technique will be a competitor candidate to the experimental and numerical techniques. Finally, the researches that relate between the different designs of the HVAC systems and energy consumption should concern with the optimization of airside design as the expected target to enhance the indoor environment.


Author(s):  
Laurentiu Predescu ◽  
Daniel Dunea

Optical monitors have proven their versatility into the studies of air quality in the workplace and indoor environments. The current study aimed to perform a screening of the indoor environment regarding the presence of various fractions of particulate matter (PM) and the specific thermal microclimate in a classroom occupied with students in March 2019 (before COVID-19 pandemic) and in March 2021 (during pandemic) at Valahia University Campus, Targoviste, Romania. The objectives were to assess the potential exposure of students and academic personnel to PM and to observe the performances of various sensors and monitors (particle counter, PM monitors, and indoor microclimate sensors). PM1 ranged between 29 and 41 μg m−3 and PM10 ranged between 30 and 42 μg m−3. It was observed that the particles belonged mostly to fine and submicrometric fractions in acceptable thermal environments according to the PPD and PMV indices. The particle counter recorded preponderantly 0.3, 0.5, and 1.0 micron categories. The average acute dose rate was estimated as 6.58 × 10−4 mg/kg-day (CV = 14.3%) for the 20–40 years range. Wearing masks may influence the indoor microclimate and PM levels but additional experiments should be performed at a finer scale.


Author(s):  
Seyed Ali Keshavarz ◽  
Mazyar Salmanzadeh ◽  
Goodarz Ahmadi

Recently, attention has been given to indoor air quality due to its serious health concerns. Clearly the dispersion of pollutant is directly affected by the airflow patterns. The airflow in indoor environment is the results of a combination of several factors. In the present study, the effects of thermal plume and respiration on the indoor air quality in a ventilated cubicle were investigated using an unsteady computational modeling approach. The person-to-person contaminant transports in a ventilated room with mixing and displacement ventilation systems were studied. The effects of rotational motion of the heated manikins were also analyzed. Simulation results showed that in the cases which rotational motion was included, the human thermal plume and associated particle transport were significantly distorted. The distortion was more noticeable for the displacement ventilation system. Also it was found that the displacement ventilation system lowered the risk of person-to-person transmission in an office space in comparison with the mixing ventilation system. On the other hand the mixing system was shown to be more effective compared to the displacement ventilation in removing the particles and pollutant that entered the room through the inlet air diffuser.


2009 ◽  
Vol 24 (3) ◽  
pp. 513 ◽  
Author(s):  
María Perevochtchikova

Se ha visto que sin un sistema de monitoreo ambiental integral y eficiente, que propor­cione datos duros de soporte para un diagnóstico de la situación ambiental, no es posible elaborar nuevas políticas públicas para resolver la problemática que enfrentan las áreas urbanas. En el presente trabajo se revisa la situación actual del sistema de monitoreo ambiental de la Zona Metropolitana de la Ciudad de México desde tres ángulos: climatológico, hidrométrico y de calidad de aire. Asimismo se detectan sus principales avances, limitaciones y otras particularidades y al final se complementa el monitoreo ambiental con la parte social y económica. AbstractIt has been proved that without an efficient, integral environmental monitoring system that provides hard back-up data for a diagnosis of the environmental situation, it is impossible to draw up new public policies to solve the problem faced by urban areas. This paper reviews the current status of environmental monitoring in the Mexico City Metropolitan Zone from three angles: climatological, hydrometric and air quality. It also detects the main progress, limitations and other particularities and at the end, environmental monitoring is complemented by the social and economic part.


2014 ◽  
Vol 29 (suppl.) ◽  
pp. 52-58
Author(s):  
Franz Roessler ◽  
Jai Azzam ◽  
Volker Grimm ◽  
Hans Hingmann ◽  
Tina Orovwighose ◽  
...  

The energy conservation regulation provides upper limits for the annual primary energy requirements for new buildings and old building renovation. The actions required could accompany a reduction of the air exchange rate and cause a degradation of the indoor air quality. In addition to climate and building specific aspects, the air exchange rate is essentially affected by the residents. Present methods for the estimation of the indoor air quality can only be effected under test conditions, whereby the influence of the residents cannot be considered and so an estimation under daily routine cannot be ensured. In the context of this contribution first steps of a method are presented, that allows an estimation of the progression of the air exchange rate under favourable conditions by using radon as an indicator. Therefore mathematical connections are established that could be affirmed practically in an experimental set-up. So this method could provide a tool that allows the estimation of the progression of the air exchange rate and in a later step the estimation of a correlating progression of air pollutant concentrations without limitations of using the dwelling.


2021 ◽  
Author(s):  
Ivan L. Pinto

The objective of this project was to provide an overview of Life Cycle Assessment (LCA) and to demonstrate its application as a tool to provide a scientific comparison of alternative construction options for a commercial building in the Canadian context. The work entailed a quantitative assessment of the embodied environmental impacts of typical office buildings using a steel frame, and a concrete frame alternative (and associated components) in Toronto. Through the use of four assessment strategies, this study has indicated that the steel framed building performs better than the concrete building in most impact indicators, excepting primary energy and eutrophication potential. However, additional buildings should be assessed in order to confirm this finding. Furthermore, it was found that the manufacturing phase represents over 90% of the embodied impacts of the whole building. The study also advises caution when comparing different LCA studies and identifies its difficulties.


2015 ◽  
Vol 10 (2) ◽  
pp. 523-528 ◽  
Author(s):  
Gurdeep Singh ◽  
Amarjeet Singh

India is in the list of fastest growing countries of the world. India's energy needs are also increasing due to population and industrial growth for improving quality of living style. In India, coal is major input infrastructure industries for example Power plants, Steel plants and Cement industries. India’s 52% of primary energy is coal dependent1. 66% of India's power generation depends upon coal production1. Jharia Coalfield (JCF) is falling in the Lower Gondwana Coalfields of India. The area of the JCF is about 450 km2. It is important for the major supply of precious coking coal required for steel plants in India. It is located in Dhanbad district of Jharkhand state of India, The latitude is 23° 39' to 23° 48' N and longitude is 86° 11' to 86° 27' E for the Jharia coalfield. Based on environmental parameters, all the 103 mines of BCCL have been grouped under 17 Clusters. A cluster consists of a group of mines with mine lease boundary lying in close vicinity and includes-Operating mines, Abandoned/ closed mines and proposed projects.The focused study area is in the western part of the Jharia coalfield is named as Cluster XV group of mines of BCCL consists of four mines, Kharkharee Colliery (UG), Dharmaband Colliery (UG), Madhuband Colliery (UG) and Phularitand Colliery (UG) .The present study was carried out with the objective to measure the ambient air quality of the study area with reference to particulate matter (SPM, PM10 & PM2.5). Ambient air monitoring results have shown that the observe air quality were found within the limit prescribed by MoEF / CPCB. It may due to Underground mines as there are pollution causing lesser activities involved in the UG mining process compared to opencast mining. Implementation of Master plan for Jharia coalfields for environmental management has also improve the air quality in the area10,11.