scholarly journals Hydrochemical Characteristics and Irrigation Suitability Evaluation of Groundwater with Different Degrees of Seawater Intrusion

Water ◽  
2020 ◽  
Vol 12 (12) ◽  
pp. 3460
Author(s):  
Zhenyan Wang ◽  
Shu Wang ◽  
Wenyue Liu ◽  
Qiao Su ◽  
Hui Tong ◽  
...  

Groundwater in coastal aquifers is often affected by seawater intrusion, resulting in water quality deterioration. Using groundwater influenced by seawater intrusion for irrigation can lead to crop failure, erosion of machinery and pipes, and adverse effects on farming. In this study, the results of water testing, methods of statistical analysis, ion ratios, a Piper diagram, and a variety of groundwater irrigation suitability models were used to analyze the chemical composition of groundwater and the influence of seawater intrusion. The result shows that the content of Na+, K+, Ca2+, Mg2+, Cl−, and SO42− in groundwater would increase due to seawater intrusion, and the increasing trend was consistent with the freshwater–seawater mixing line. With the deepening of seawater intrusion, the hydrochemical type gradually changes from Ca-HCO3·Cl to Na·Mg-Cl·SO4 and then to Na-Cl type, and the source of hydrochemical composition changes from “Rock Weathering Dominance” to “Evaporation Dominance”. When the Cl− concentration is greater than 7.1 meq/L, groundwater will corrode pipelines and instruments; when greater than 28.2 meq/L, excessively high salinity of groundwater will have adverse effects on planting; and when greater than 14.1 meq/L, the groundwater hardness is too high, which may make the groundwater unsuitable for cultivation.

Author(s):  
J N Chapman ◽  
W A P Nicholson

Energy dispersive x-ray microanalysis (EDX) is widely used for the quantitative determination of local composition in thin film specimens. Extraction of quantitative data is usually accomplished by relating the ratio of the number of atoms of two species A and B in the volume excited by the electron beam (nA/nB) to the corresponding ratio of detected characteristic photons (NA/NB) through the use of a k-factor. This leads to an expression of the form nA/nB = kAB NA/NB where kAB is a measure of the relative efficiency with which x-rays are generated and detected from the two species.Errors in thin film x-ray quantification can arise from uncertainties in both NA/NB and kAB. In addition to the inevitable statistical errors, particularly severe problems arise in accurately determining the former if (i) mass loss occurs during spectrum acquisition so that the composition changes as irradiation proceeds, (ii) the characteristic peak from one of the minority components of interest is overlapped by the much larger peak from a majority component, (iii) the measured ratio varies significantly with specimen thickness as a result of electron channeling, or (iv) varying absorption corrections are required due to photons generated at different points having to traverse different path lengths through specimens of irregular and unknown topography on their way to the detector.


Author(s):  
Nestor J. Zaluzec

The application of electron energy loss spectroscopy (EELS) to light element analysis is rapidly becoming an important aspect of the microcharacterization of solids in materials science, however relatively stringent requirements exist on the specimen thickness under which one can obtain EELS data due to the adverse effects of multiple inelastic scattering.1,2 This study was initiated to determine the limitations on quantitative analysis of EELS data due to specimen thickness.


Author(s):  
Dirk K. Wolter

Zusammenfassung. Zielsetzung: Übersicht über Suchtpotenzial und andere Risiken von Opioidanalgetika im höheren Lebensalter. Methodik: Narrativ review. Literaturrecherche in PubMed (Suchbegriffe: opioid analgesics UND abuse; opioid analgesics UND dependence; opioid analgesics UND addiction; opioid analgesics UND adverse effects; jeweils UND elderly) sowie aktuellen einschlägigen Standardwerken; Auswahl nach altersmedizinischer Relevanz und Aktualität. Ergebnisse: Die Verordnung von Opioidanalgetika (OA) hat in den letzten 25 Jahren massiv zugenommen, die weitaus meisten Verordnungen entfallen auf alte Menschen und Menschen mit chronischen Nicht-Tumorschmerzen (CNTS). Die diagnostischen Kriterien für die Opiatabhängigkeit in ICD-10 und DSM-5 sind für die OA-Behandlung von CNTS ungeeignet. Bei langfristiger OA-Behandlung bei CNTS kann eine spezifische Form von Abhängigkeit entstehen, die nicht mit der illegalen Opiat-(Heroin-)Sucht gleichzusetzen ist. Vorbestehende Suchterkrankungen und andere psychische Störungen sind die wesentlichsten Risikofaktoren. Weitere Nebenwirkungen sind zu beachten. Schmerztherapie bei Suchtkranken stellt eine besondere Herausforderung dar. Schlussfolgerungen: Die Anwendung von OA bei CNTS verlangt eine sorgfältige Indikationsstellung. Die besondere Form der Abhängigkeit von OA ist nicht ausreichend erforscht und wird zu wenig beachtet.


2018 ◽  
Vol 32 (4) ◽  
pp. 182-190 ◽  
Author(s):  
Kenta Matsumura ◽  
Koichi Shimizu ◽  
Peter Rolfe ◽  
Masanori Kakimoto ◽  
Takehiro Yamakoshi

Abstract. Pulse volume (PV) and its related measures, such as modified normalized pulse volume (mNPV), direct-current component (DC), and pulse rate (PR), derived from the finger-photoplethysmogram (FPPG), are useful psychophysiological measures. Although considerable uncertainties exist in finger-photoplethysmography, little is known about the extent of the adverse effects on the measures. In this study, we therefore examined the inter-method reliability of each index across sensor positions and light intensities, which are major disturbance factors of FPPG. From the tips of the index fingers of 12 participants in a resting state, three simultaneous FPPGs having overlapping optical paths were recorded, with their light intensity being changed in three steps. The analysis revealed that the minimum values of three coefficients of Cronbach’s α for ln PV, ln mNPV, ln DC, and PR across positions were .948, .850, .922, and 1.000, respectively, and that those across intensities were .774, .985, .485, and .998, respectively. These findings suggest that ln mNPV and PR can be used for psychophysiological studies irrespective of minor differences in sensor attachment positions and light source intensity, whereas and ln DC can also be used for such studies but under the condition of light intensity being fixed.


Sign in / Sign up

Export Citation Format

Share Document