scholarly journals Aplicação da ferramenta estatística Análise de Componentes Principais (ACP) na identificação e análise da qualidade de estação de tratamento de água para hemodiálise / Application of the Principal Component Analysis (PCA) statistical tool in the identification and analysis of the quality of a water treatment plant for hemodialysis

2021 ◽  
Vol 7 (12) ◽  
pp. 111171-111183
Author(s):  
Thayná Rhomana da Silva Cândido ◽  
Ana Patrícia da Conceição Dos Santos ◽  
Rafael de Souza Mendonça ◽  
Maria Eduarda Araújo de Andrade Lemos Donato ◽  
Valberto Barbosa De Oliveira ◽  
...  
2018 ◽  
Vol 10 (11) ◽  
pp. 4239 ◽  
Author(s):  
Marina Valentukevičienė ◽  
Lina Bagdžiūnaitė-Litvinaitienė ◽  
Viktoras Chadyšas ◽  
Andrius Litvinaitis

The trans-boundary area between the Europe Union and other countries is highly susceptible to changes in water quality and variations in the potential pollution load that could influence its eco-systems significantly. The Neris (Viliya) River is one of the biggest surface water bodies in Lithuania and Belarus with an ecologically important area protected by international legislation. The study was aimed at evaluating the impacts of integrated pollution on water quality of the Neris River taking into account different storm-water flows and ecological scenarios. For this purpose, qualitative and quantitative statistical evaluation was set up and calculation was done; different integrated pollution loads of the catchment area were estimated. The evaluation considered a decrease in river discharge due to changes in the regional storm-water flow and technological development that should lead to the growing covered surface and a reduction in the untreated storm-water flows. The obtained results indicated that, in the case of storm-water treatment, the total nitrate and phosphate concentrations will decrease, while in the cases of changes in combined suspended solid, the concentration of nutrients will decrease. Thus, a trans-boundary storm-water treatment plant of the Viliya River is required as it should eliminate pollution accumulation and restore its acceptable environmental status. A coordinated international project for the entire catchment of the Neris (Viliya) River based on the specifications and requirements of the EU Water Framework Directive (EU 2000) should be developed and implemented. Subsequently, ecological river-use policies should be established at the international level, which should offer considerable perspectives for the sustainable development of the area.


2019 ◽  
Vol 8 (3) ◽  
pp. 93-101
Author(s):  
Paulami De

This article addresses methods to adjust operating requirements in water treatment plants (WTPs) in order to increase the efficiency of water treatment plants based on the nature of the water inflows into the systems. In the past, various studies have suggested that the quality of water inflow into the WTP has an impact on the efficiency and economic viability of operating treatment plants. Among all other quality parameters, the concentration of dissolved oxygen (DO) is one of the basic indicators about the overall quality of the water. Identification of a temporal pattern can help the engineers to adapt the WTP operations and can save the unnecessary wasting of plant resources. That is why the present article has proposed a new model that can predict the temporal patterns of various chemical parameters with the help of an analytic neuronal network. The model was applied to the case of a WTP that responds to a peri-urban catchment, leading to regular variations in the DO of water inflow. According to the performance metrics utilized the model was able to predict the temporal pattern at a lag of 1 hour.


2014 ◽  
Vol 70 (3) ◽  
Author(s):  
Siti Nur Suhaila Mirin ◽  
Norhaliza Abdul Wahab

Safety, environmental regulations, the cost of maintenance and the operation of sewage treatment plants are some of the many reasons researchers have carried out countless research studies into fault detection and monitoring over the years. Conventional principal component analysis (PCA) in particular has been used in the field of fault detection, where the technique is able to separate useful information from multivariate data. However, conventional PCA can only be used on data that has a constant mean, which is rare in sewage treatment plants. Consequently, the success of combining wavelet and conventional PCA has attracted many researchers to apply it to fault detection where the wavelet is capable of separating data into several time scales. The separated data will be approximated to a constant mean. In addition, the conventional PCA only captures the correlation across the data, unlike multiscale PCA (MSPCA) which captures the correlation within the data and across the data. Therefore, in this work, MSPCA is introduced to improve the performance of PCA in fault detection. The objective of this paper is to reduce false alarms that exist in PCA fault detection and monitoring. Data from the Bunus sewage treatment plant (Bunus STP) is used and analysed using conventional PCA with Hotelling’s T2 and the squared prediction error (SPE). MSPCA with Hotelling’s T2 and SPE is used to improve the efficiency of fault detection and monitoring performance in conventional PCA. Therefore, MSPCA is successful in improving conventional PCA in fault detection and monitoring by reducing false alarms. 


Molecules ◽  
2019 ◽  
Vol 24 (14) ◽  
pp. 2674 ◽  
Author(s):  
Tianchen Ma ◽  
Haoan Zhao ◽  
Caiyun Liu ◽  
Min Zhu ◽  
Hui Gao ◽  
...  

Honey maturity is an important factor in evaluating the quality of honey. We established a method for the identification of natural mature acacia honey with eighteen physicochemical parameters combined with chemometric analysis. The analysis of variance showed significant differences between mature and immature acacia honey in physicochemical parameters. The principal component analysis explained 82.64% of the variance among samples, and indicated that total phenolic content, total protein content, and total sugar (glucose, fructose, sucrose) were the major variables. The cluster analysis and orthogonal partial least squares-discriminant analysis demonstrated that samples were grouped in relation to the maturity coinciding with the results of the principal component analysis. Meanwhile, the 35 test samples were classified with 100% accuracy with the method of multi-physicochemical parameters combined with chemometric analysis. All the results presented above proved the possibility of identifying mature acacia honey and immature acacia honey according to the chemometric analysis based on the multi-physicochemical parameters.


Sign in / Sign up

Export Citation Format

Share Document