The Determination of Radon Diffusion Coefficient and Radon Speed Advection in the Conditions of Instantaneous Source with Diffusion-Advective Transfer in Rocks

ANRI ◽  
2020 ◽  
pp. 54-60
Author(s):  
A. Yurkov ◽  
S. Biryulin ◽  
I. Kozlova

Experimental determination of diffusion parameters in the upper part of geological section (presented by clayey weathering crust) was made by a point instantaneous source method in a diffusion mode and a linear instantaneous source diffusion-advective mode. The results obtained by these methods showed a fairly good coincidence of the obtained diffusion characteristics of the medium. The time to determine the diffusion characteristics of the medium is significantly reduced by more than an order of magnitude when using the advective method. This is a prerequisite for the widespread use of methods for determining radon hazard based on measurements of the vertical distribution of radon volume activity in the upper part of the geological section.

2018 ◽  
Vol 173 ◽  
pp. 06009 ◽  
Author(s):  
Eduard G. Nikonov ◽  
Miron Pavluš ◽  
Mária Popovičová

One of the varieties of pores, often found in natural or artificial building materials, are the so-called blind pores of dead-end or saccate type. Three-dimensional model of such kind of pore has been developed in this work. This model has been used for simulation of water vapor interaction with individual pore by molecular dynamics in combination with the diffusion equation method. Special investigations have been done to find dependencies between thermostats implementations and conservation of thermodynamic and statistical values of water vapor – pore system. The two types of evolution of water – pore system have been investigated: drying and wetting of the pore. Full research of diffusion coefficient, diffusion velocity and other diffusion parameters has been made.


2019 ◽  
Vol 7 (2A) ◽  
Author(s):  
Camilo Fuentes Serrano ◽  
Juan Reinaldo Estevez Alvares ◽  
Alfredo Montero Alvarez ◽  
Ivan Pupo Gonzales ◽  
Zahily Herrero Fernandez ◽  
...  

A method for determination of Cr, Fe, Co, Ni, Cu, Zn, Hg and Pb in waters by Energy Dispersive X Ray Fluorescence (EDXRF) was implemented, using a radioisotopic source of 238Pu. For previous concentration was employed a procedure including a coprecipitation step with ammonium pyrrolidinedithiocarbamate (APDC) as quelant agent, the separation of the phases by filtration, the measurement of filter by EDXRF and quantification by a thin layer absolute method. Sensitivity curves for K and L lines were obtained respectively. The sensitivity for most elements was greater by an order of magnitude in the case of measurement with a source of 238Pu instead of 109Cd, which means a considerable decrease in measurement times. The influence of the concentration in the precipitation efficiency was evaluated for each element. In all cases the recoveries are close to 100%, for this reason it can be affirmed that the method of determination of the studied elements is quantitative. Metrological parameters of the method such as trueness, precision, detection limit and uncertainty were calculated. A procedure to calculate the uncertainty of the method was elaborated; the most significant source of uncertainty for the thin layer EDXRF method is associated with the determination of instrumental sensitivities. The error associated with the determination, expressed as expanded uncertainty (in %), varied from 15.4% for low element concentrations (2.5-5 μg/L) to 5.4% for the higher concentration range (20-25 μg/L).


2003 ◽  
Vol 253 (1-4) ◽  
pp. 174-182 ◽  
Author(s):  
J. Marcon ◽  
M. Ihaddadene ◽  
K. Ketata

Molecules ◽  
2021 ◽  
Vol 26 (5) ◽  
pp. 1238
Author(s):  
Eduardo Laga ◽  
David Dalmau ◽  
Sofía Arregui ◽  
Olga Crespo ◽  
Ana I. Jimenez ◽  
...  

The goal of the work reported here was to amplify the fluorescent properties of 4-aryliden-5(4H)-oxazolones by suppression of the hula-twist non-radiative deactivation pathway. This aim was achieved by simultaneous bonding of a Pd center to the N atom of the heterocycle and the ortho carbon of the arylidene ring. Two different 4-((Z)-arylidene)-2-((E)-styryl)-5(4H)-oxazolones, the structures of which are closely related to the chromophore of the Kaede protein and substituted at the 2- and 4-positions of the arylidene ring (1a OMe; 1b F), were used as starting materials. Oxazolones 1a and 1b were reacted with Pd(OAc)2 to give the corresponding dinuclear orthometalated palladium derivates 2a and 2b by regioselective C–H activation of the ortho-position of the arylidene ring. Reaction of 2a (2b) with LiCl promoted the metathesis of the bridging carboxylate by chloride ligands to afford dinuclear 3a (3b). Mononuclear complexes containing the orthopalladated oxazolone and a variety of ancillary ligands (acetylacetonate (4a, 4b), hydroxyquinolinate (5a), aminoquinoline (6a), bipyridine (7a), phenanthroline (8a)) were prepared from 3a or 3b through metathesis of anionic ligands or substitution of neutral weakly bonded ligands. All species were fully characterized and the X-ray determination of the molecular structure of 7a was carried out. This structure has strongly distorted ligands due to intramolecular interactions. Fluorescence measurements showed an increase in the quantum yield (QY) by up to one order of magnitude on comparing the free oxazolone (QY < 1%) with the palladated oxazolone (QY = 12% for 6a). This fact shows that the coordination of the oxazolone to the palladium efficiently suppresses the hula-twist deactivation pathway.


1983 ◽  
Vol 40 (5) ◽  
pp. 637-643 ◽  
Author(s):  
C. W. Pugsley ◽  
H. B. N. Hynes

A freeze-coring device using liquid nitrogen is described, which enables one person to take a columnar core, extending from the surface to at least 50 cm below a stony streambed. An experiment to validate the technique showed that animals did not flee from the advance of the freezing-front. Using frozen streambed cores, the vertical distribution of benthic invertebrates of two streams in southern Ontario was investigated. In contrast to previous estimates,~70% of the fauna was found in the top 10 cm of the streambed, and invertebrate densities were often lower by an order of magnitude. These differences are attributed to problems of quantifying previous sampling methods.


1997 ◽  
Vol 12 (11) ◽  
pp. 1967-1974 ◽  
Author(s):  
Kazuaki Kuroda ◽  
Mark A. Barton ◽  
Atsushi Onae ◽  
Yukinobu Miki

We propose the application of a new technique, the X pendulum, to determine the Newtonian gravitational constant G. We evaluate the likely experimental errors for configurations realizable with existing technologies and show that improvement of the accuracy by an order of magnitude or more is possible.


2021 ◽  
Author(s):  
Larisa A. Chipiga ◽  
Anna E. Petrova ◽  
Artem A. Mosunov ◽  
Laura T. Naurzbaeva ◽  
Stanislaus M. Kushnarenko ◽  
...  

In connection with the constantly increasing use of monoclonal antibodies labeled with 89Zr, in clinical practice, it is urgent to study their pharmacokinetics with the determination, based on the data obtained, of absorbed doses in tumor foci, as well as intact organs and tissues, and effective doses of patients. To date, there are a limited number of studies that provide patient doses for diagnostic examinations using 89Zr-labeled monoclonal antibodies. In this regard, the purpose of this work was to assess the biodistribution of various monoclonal antibodies (ramucirumab, trastuzumab, atezolizumab) labeled with 89Zr, based on published data, with subsequent calculation of absorbed doses in radiosensitive organs and tissues and effective doses of patients. Based on the analysis of experimental data on the biodistribution of monoclonal antibodies labeled with 89Zr for the diagnosis of oncological diseases from the available literature sources and our own assessments, it has been concluded that the results of the determination of absorbed in organs and tissues and effective doses are inconsistent. The absorbed doses in organs, according to different literature sources, vary up to an order of magnitude within one organ and reach 440 mGy per examination, the effective dose varies from 3 to 112 mSv per examination. This may be due to differences in study design, radiometry and dose assessment methods. Comparison with doses obtained on the basis of a general model of biodistribution of monoclonal antibodies demonstrates the possibility of using this model for a rough estimate of internal doses of patients. However, for a more accurate assessment, it is necessary to standardize approaches to the determination of internal radiation doses using the most effective methodological solutions and software products.


2004 ◽  
Vol 08 (11) ◽  
pp. 1311-1324 ◽  
Author(s):  
Maddalena Pizzotti ◽  
Elisabetta Annoni ◽  
Renato Ugo ◽  
Silvia Bruni ◽  
Silvio Quici ◽  
...  

A multitechnique investigation of the determination of the order of magnitude of the second and third order NLO response of [5-[(4-dimethylaminophenyl)ethynyl]-15-[(4-nitrophenyl)ethynyl]-10,20-diphenylporphyrinato]nickel(II) (1) is reported with the aim to produce self consistent evidence for a significant NLO response of this kind of push-pull porphyrin chromophore. The experimental multitechnique approach is based on the EFISH technique, working with a non-resonant incident wavelength of 1.907 μm, on the solvatochromic method and finally on a vibrational method, avoiding any fluorescence or resonance interference. A theoretical MNDO-TDHF evaluation of the zero-frequency quadratic and cubic hyperpolarizabilities of an ab initio optimized planar structure is also reported. The order of magnitude of the quadratic hyperpolarizability of (1) at zero frequency (β0), was found to be significantly lower than that reported for the corresponding Cu (II) or Zn (II) complexes with the same push-pull porphyrin chromophore.


Sign in / Sign up

Export Citation Format

Share Document