scholarly journals PLASMA COATING FORMED TIO2 CATALYSTS USAGE IN CLEANING THE AIR FROM NITROGEN OXIDES AND CARBON MONOXIDE / PLAZMINIU PURŠKIMU SUFORMUOTŲ TIO2 KATALIZATORIŲ TAIKYMAS VALANT IŠ ORO AZOTO OKSIDUS IR ANGLIES MONOKSIDĄ

2015 ◽  
Vol 7 (4) ◽  
pp. 365-371
Author(s):  
Vitalij Kolodynskij ◽  
Pranas Baltrėnas

The present catalytic air purification device–air cleaning device is capable to reduce nitrogen oxide sand carbon monoxide concentrations in polluted air stream and to achieve high cleaning efficiency. The principle of operation of catalytic air cleaning device is based on plasma coating formed catalysts usage. At high temperatures and oxygen concentrations in the experimental device channel, catalysts become active and reactions of conversion of pollutants start. In this research, the efficiency of cleaning the air from nitrogen oxides and carbon monoxide, by using plasma coating formed titanium oxide and copper-chromium catalysts, is carried out. 50% propane – 50% butane gas mix was used to generate polluted air flow. The maximum cleaning efficiency, cleaning the air of nitrogen oxides and carbon monoxide, reached 86% and 77%, when the average flow rate of polluted air was 0.10 m/s, oxygen concentration in II section of device was 0.5–0.6% and in I section – 0.1–0.2%. Nagrinėjamas įrenginys – katalitinis oro valymo įrenginys, mažinantis azoto oksidų ir anglies monoksido koncentracijas užterštame oro sraute. Katalitinis oro valymo įrenginys veikia naudodamas plazminiu purškimu suformuotus katalizatorius. Esant aukštai temperatūrai ir optimaliai deguonies koncentracijai įrenginio eksperimentiniame kanale, katalizatorių paviršius tampa aktyvus, ir vyksta sudėtingos teršalų konversijos reakcijos. Atliktuose tyrimuose nagrinėtas suminis titano oksido ir vario-chromo oksido katalizatorių, kurie buvo pagaminti plazminio purškimo metodu, srauto, užteršto azoto oksidais ir anglies monoksidu, valymo efektyvumas. Užterštam oro srautui sugeneruoti buvo naudojamas 50 % propano – 50 % butano dujų mišinys. Didžiausias valymo efektyvumas, valant orą nuo azoto oksidų ir anglies monoksido, atitinkamai siekė 86 % ir 77 %, esant 0,10 m/s vidutiniam užteršto srauto greičiui, 0,5–0,6 % deguonies koncentracijai II-ojoje įrenginio sekcijoje ir 0,1–0,2 % deguonies koncentracijai I-ojoje įrenginio sekcijoje.

2013 ◽  
Vol 5 (4) ◽  
pp. 376-381 ◽  
Author(s):  
Alvydas Zagorskis ◽  
Aleksandra Milaknytė

Air cleaning efficiency tests on placing material load into the lavsan biofilter were carried out. Testing included butanol vapour-contaminated air stream pulled during the boot. The studies were conducted by the Department of Environmental Protection at VGTU that developed a biofilter – an experimental biological air cleaning device. Measurements were done using 60 l/min and 90 l/min air volume aspirators under the initial pollutant concentration making 180, 305, 350, 440 and 545 mg/m3. Before measuring the concentrations of butanol lavsan cartridge, loading was periodically irrigated with nutrient-rich solution. In order to evaluate the influence of microorganisms on genus Pseudomonas, cleaning efficiency tests were repeated – Boot was moistened with water only, which allowed measuring butanol vapour concentrations after the cartridge. At the concentration of 180±9 mg/m3, efficiency reached 41% at a speed of 0,07 m/s and 46 % at a speed of 0,10 m/s. Measuring the performance of the initial concentration of 545±67 mg/m3, efficiency was 54% at 0,07 m/s and 53 % at 0,10 m/s respectively. Article in Lithuanian. Santrauka Atlikti oro valymo efektyvumo tyrimai į lašelinį biofiltrą įkrovus lavsano medžiagos įkrovą. Bandymų metu pro įkrovą buvo traukiamas butanolio garais užterštas oro srautas. Tyrimai atliekami naudojant VGTU Aplinkos apsaugos katedroje sukurtą eksperimentinį biologinį oro valymo įrenginį – biofiltrą. Matavimai atlikti leidžiant 60 l/min. ir 90 l/min. oro kiekį aspiratoriumi. Pradinės teršalo koncentracijos – 180, 305, 350, 440, 545 mg/m3. Prieš matuojant butanolio koncentracijas panaudojant lavsano medžiagos kasetę, įkrova buvo periodiškai drėkinama maistinių medžiagų prisotintu tirpalu. Pseudomonas genties mikroorganizmų įtakai valymo efektyvumui įvertinti tyrimai buvo pakartoti – įkrovos sudrėkinamos tik vandeniu, leidžiami butanolio garai, ir matuojamos koncentracijos panaudojus lavsano medžiagos kasetę. Esant 180±89 mg/m3 koncentracijai biofiltro oro valymo efektyvumas siekė 41 %, kai per įkrovą leidžiamo dujų srauto greitis buvo 0,07 m/s, ir 46 %, kai greitis 0,10 m/s. Nustatyta valymo efektyvumas. Esant 545±55 mg/m3 pradinei koncentracijai jis siekė 54 % (0,07 m/s) ir 53 % (0,10 m/s).


Processes ◽  
2020 ◽  
Vol 8 (3) ◽  
pp. 346
Author(s):  
Zbigniew Krzysiak ◽  
Waldemar Samociuk ◽  
Janusz Zarajczyk ◽  
Zdzisław Kaliniewicz ◽  
Daniel Pieniak ◽  
...  

The article presents some of the research on the wider work related to testing and improving a new rotary cleaning device. The new cereal grain cleaning and separation device can support the development of sustainable agriculture in terms of seed purity and quality. This device is especially useful for small and medium-sized farms. This device has the characteristics of a multi-stage screen aided by an air stream (i.e., by pneumoseparation). The prototype was constructed at the University of Life Sciences in Lublin. The research was conducted at a test stand, which allowed changes in the operating parameters of the cleaner and their measurement. The scope of the tests included determining the influence of the inclination angle of the sieve unit (α) on the effectiveness and efficiency of oat grain cleaning. The experiment was carried out using two rotational spindle speeds: 5 and 75 rpm. The quality of the separation and cleaning of oat grains was evaluated using six cleaning process parameters: plump grain mass separation coefficient (Spg), fine grain separation coefficient (Sfg), fine impurities separation coefficient (Sfi), chaff separation coefficient (Sch), total coefficient of cleaning effectiveness (E), plump grain cleaning efficiency (qpg). Results showed the significant effect of the sieve drum inclination angle on the efficiency and effectiveness of oat grain cleaning.


2015 ◽  
Vol 7 (4) ◽  
pp. 380-384
Author(s):  
Denas Bacevičius ◽  
Alvydas Zagorskis

Volatile organic compounds, e. g. acetone, have a direct impact on climate change, decrease of ozone in the air, and on the growth of greenhouse effect. One of the most popular air purifying methods from VOC is a biological air cleaning. Experimental investigations were conducted to determine the efficiency of the new structure of biofilter with polypropylene plates segments. During the investigations the efficiency of segmental construction biofilter of air purification at different initial concentrations of pollutants was determined. Different concentrations of pollutants were estimated during the acetone dilution with water. During the tests the efficiency of biofilter air purification from acetone vapor and its change under different concentrations of vapors was set. Based on test results, the maximum efficiency of biofilter air purification was up to 93%. Studies have shown that increasing the allowable pollutant concentration, the efficiency of air purification unit decreases. Increasing the concentration of supplied acetone vapor into the biofilter from 232 to 701 mg/m3, cleaning efficiency decreased from 92.8 to 82.3%. Since microorganisms fail to oxidize organic compounds, the filter works better at lower initial concentrations of pollutants. Lakieji organiniai junginiai, tokie kaip acetonas, turi tiesioginę įtaką klimato kaitai, ozono kiekio ore mažėjimui, šiltnamio efekto susidarymui. Vienas populiariausių oro valymo nuo LOJ metodų yra biologinis oro valymas. Eksperimentiniai tyrimai atlikti siekiant nustatyti naujos konstrukcijos biofiltro, užkrauto polipropileno plokštelių segmentais, efektyvumą. Tyrimų metu buvo nustatinėjamas segmentinės konstrukcijos oro valymo biofiltro efektyvumas, esant skirtingoms pradinėms teršalo koncentracijoms. Skirtingos teršalo koncentracijos gautos acetoną skiedžiant vandeniu. Bandymų metu nustatytas biofiltro oro valymo nuo acetono garų efektyvumas, jo kaita esant skirtingoms garų koncentracijoms. Remiantis bandymų rezultatais, didžiausias nustatytas biofiltro oro valymo efektyvumas siekė 93 %. Tyrimų metu nustatyta, kad didinant leidžiamo teršalo koncentraciją, įrenginio valymo efektyvumas mažėja. Padidinus į biofiltrą tiekiamų acetono garų koncentraciją nuo 232 iki 701 mg/m3, valymo efektyvumas sumažėjo nuo 92,8 iki 82,3 %. Kadangi mikroorganizmai nespėja oksiduoti organinių junginių, filtras geriau veikia esant mažesnėms pradinėms teršalų koncentracijoms.


2021 ◽  
Vol 75 (4) ◽  
pp. 241-251
Author(s):  
Aleksandras Chlebnikovas

The main aim of this investigation was an experimental analysis of the air cleaning efficiency in a mock-up next-generation air cleaning device - one-level 8-channel industrial cyclone-separator with quarter-rings - while changing parameters of the inner structure and the assessment of the effects of dispersion of particulate matter. Therefore, the research was carried out in two stages: the first stage covered the analysis of the efficiency of the multi-channel cyclone with particulate matter of <20 and <50 ?m. During the second stage, a cascade impactor was used to measure the particle collection efficiency in the multi-channel cyclone by fractions: PM1, PM2.5 and PM10. Results of the tests with using the cascade impactor were compared to show changes in the PM composition before and after the multi-channel cyclone-separator. According to the obtained experimental data, the one-level 8-channel cyclone-separator collects 70 to 80 % of PM up to 10 ?m in size, 45 to 60 % of PM up to 2.5 ?m in size and 21 to 25 % of PM up to 1 ?m in size.


2021 ◽  
Vol 7 (Special) ◽  
pp. 13-13
Author(s):  
Leonid Andreev ◽  
◽  
Vladimir Yurkin

The allocation of intake air stream in pig premises is not evenly. The existence of engineer-ing networks and equipment, the breaching of montage technologies of air ventilation, incorrect maintenance of air ventilation system – all these factors bring to many breaches and problems. This problem such as air exchange violation in all premises, appearing zones of stasis (aero stasis), and others. As a result of which the differential of temperature and humidity has appeared. These also appear excess maximum per-mitted concentration of dust and gases. The all-exchanged ven-tilation system can’t solve all problems in local zones in pig premises. In this local air-ventilation system become more demand. For effective work of local air ventilation, the question of deter-mining installation sites for the air purification of pig premises local system elements should be solved. Keywords: LOCAL VENTILATION, AIR CLEANING FROM DUST, DUST RELEASE, HARMFUL GAS CLEANING


2012 ◽  
Vol 33 (2) ◽  
pp. 231-242 ◽  
Author(s):  
Marek Juszczak ◽  
Katarzyna Lossy

Pollutant emission from a heat station supplied with agriculture biomass and wood pellet mixtureTests for combustion of hay and sunflower husk pellets mixed with wood pellets were performed in a horizontal-feed as well as under-feed (retort) wood pellet furnace installed in boilers with a nominal heat output of 15 and 20 kW, located in a heat station. During the combustion a slagging phenomenon was observed in the furnaces. In order to lower the temperature in the furnace, fuel feeding rate was reduced with unaltered air stream rate. The higher the proportion of wood pellets in the mixture the lower carbon monoxide concentration. The following results of carbon monoxide concentration (in mg/m3presented for 10% O2content in flue gas) for different furnaces and fuel mixtures (proportion in wt%) were obtained: horizontal-feed furnace supplied with hay/wood: 0/100 - 326; 30/70 - 157; 50/50 - 301; 100/0 - 3300; horizontal-feed furnace supplied with sunflower husk/wood: 50/50 - 1062; 67/33 - 1721; 100/0 - 3775; under-feed (retort) furnace supplied with hay/wood: 0/100 - 90; 15/85 - 157; 30/70 - 135; 50/50 - 5179; under-feed furnace supplied with sunflower husk/wood: 67/33 - 2498; 100/0 - 3128. Boiler heat output and heat efficiency was low: 7 to 13 kW and about 55%, respectively, for the boiler with horizontal-feed furnace and 9 to 14 kW and 64%, respectively, for the boiler with under-feed furnace.


1987 ◽  
Vol 109 (2) ◽  
pp. 150-155 ◽  
Author(s):  
M. P. Malkin ◽  
S. A. Klein ◽  
J. A. Duffie ◽  
A. B. Copsey

A modification to the f-Chart method has been developed to predict monthly and annual performance of thermosyphon solar domestic hot water systems. Stratification in the storage tank is accounted for through use of a modified collector loss coefficient. The varying flow rate throughout the day and year in a thermosyphon system is accounted for through use of a fixed monthly “equivalent average” flow rate. The “equivalent average” flow rate is that which balances the thermosyphon buoyancy driving force with the frictional losses in the flow circuit on a monthly average basis. Comparison between the annual solar fraction predited by the modified design method and TRNSYS simulations for a wide range of thermosyphon systems shows an RMS error of 2.6 percent.


2021 ◽  
pp. 28-32
Author(s):  
VALERIY L. CHUMAKOV ◽  

The paper shows some ways to improve the environmental characteristics of a diesel engine using gaseous hydrocarbon fuel and operating the engine in a gas-diesel cycle mode. Some possibilities to reduce toxic components of exhaust gases in a gas-diesel engine operating on liquefi ed propane-butane mixtures have been studied. Experiments carried out in a wide range of load from 10 to 100% and speed from 1400 to 2000 rpm showed that the gas-diesel engine provides a suffi ciently high level of diesel fuel replacement with gas hydrocarbon fuel. The authors indicate some eff ective ways to reduce the toxicity of exhaust gases. The engine power should be adjusted by the simultaneous supply of fuel, gas and throttling the air charge in the intake manifold. This method enriches the fi rst combusting portions to reduce nitrogen oxides and maintains the depletion of the main charge within the fl ammability limits of the gas-air charge to reduce carbon monoxide and hydrocarbons. The authors found that when the engine operates in a gas-diesel cycle mode, the power change provides a decrease in nitrogen oxide emissions of gas-diesel fuel only due to gas supply in almost the entire load range as compared to the pure diesel. At high loads (more than 80%) stable engine operation is ensured up to 90% of diesel fuel replaced by gas. Even at 10% of diesel fuel used the concentration of nitrogen oxides decreases by at least 15…20% as compared with a diesel engine in the entire load range. However, there is an increased emission of hydrocarbons and carbon monoxide in the exhaust gases. Further experimental studies have shown that optimization of the gas diesel regulation can reduce the mass emission of nitrogen oxides contained in exhaust gases in 2…3 times and greatly reduce the emission of incomplete combustion products – carbon monoxide and hydrocarbons.


2018 ◽  
Vol 44 ◽  
pp. 00056 ◽  
Author(s):  
Sylwia Janta-Lipińska ◽  
Alexander Shkarovskiy

Nitrogen oxides are considered to be much more toxic than, for example, carbon monoxide. For this reason, the Authors developed and implemented a method for decrease of NOX emission into the atmosphere from DKVR 10-13 boilers. As an effective method for boilers propose injection of steam into the combustion zone. After series of experimental studies an optimal design of the head for steam injection was developed, according to the proprietary technology. The injector head was kept unchanged while the spraying end caps were modified (Fig. 2). Three levels of possible impact of emissions from boiler on the atmosphere pollution were taken into account during studies. After the analysis, it was assumed that the level of the real maximum emission should be taken as the reference level in relation to which the decrease of NOX emission should be determined. The results obtained by the Authors calculated into mass emission and as objective values of nitrogen oxides concentration calculated into α = 1 (Figures 3 and 4). Realization of the study plan, assumed by the Authors, allowed to determine the optimal parameters of the NOx emission decrease method, assuming the expected 30% level of emission decrease at a limited consumption of injected.


Sign in / Sign up

Export Citation Format

Share Document