Fixation of Multifragmentary Patella Fractures Using a Bilateral Fixed-angle Plate

Orthopedics ◽  
2013 ◽  
Vol 36 (11) ◽  
pp. e1437-e1443 ◽  
Author(s):  
Simon Thelen ◽  
Marcel Betsch ◽  
Johannes Schneppendahl ◽  
Jan Grassmann ◽  
Mohssen Hakimi ◽  
...  
Injury ◽  
2016 ◽  
Vol 47 (8) ◽  
pp. 1737-1743 ◽  
Author(s):  
Michael Wild ◽  
Kai Fischer ◽  
Florian Hilsenbeck ◽  
Mohssen Hakimi ◽  
Marcel Betsch

2012 ◽  
Vol 21 (2) ◽  
pp. 311-317 ◽  
Author(s):  
Simon Thelen ◽  
Johannes Schneppendahl ◽  
Ralf Baumgärtner ◽  
Christian Eichler ◽  
Jürgen Koebke ◽  
...  

2011 ◽  
Vol 16 (1) ◽  
pp. 41 ◽  
Author(s):  
M Wild ◽  
S Thelen ◽  
P Jungbluth ◽  
M Betsch ◽  
D Miersch ◽  
...  

Injury ◽  
2012 ◽  
Vol 43 (8) ◽  
pp. 1290-1295 ◽  
Author(s):  
Simon Thelen ◽  
Johannes Schneppendahl ◽  
Eva Jopen ◽  
Christian Eichler ◽  
Jürgen Koebke ◽  
...  

2011 ◽  
Vol 93 (1) ◽  
pp. 57-60 ◽  
Author(s):  
DC Perry ◽  
DMG Machin ◽  
JA Casaletto ◽  
DJ Brown

INTRODUCTION Rupture of extensor pollicis longus (EPL) tendon is a recognised complication following volar plate fixation of distal radius fractures, usually from attrition caused by prominent screws. We sought to identify the screw holes in some of the most commonly used plates which may precipitate tendon injury. SUBJECTS AND METHODS Three fixed-angle volar locking plates were sequentially positioned into 18 cadaveric arms. A wire was passed through each of the holes in the plates using a locking guide and the dorsal relationships noted. RESULTS Each plate had specific ‘high-risk’ holes which directed the wire towards the EPL groove. The central screw holes appeared mostly implicated in EPL injury. CONCLUSIONS Awareness of ‘high-risk’ holes and appropriate minor alterations in surgical technique may consequently decrease the incidence of EPL irritation and rupture.


2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Puripun Jirangkul ◽  
Arkaphat Kosiyatrakul

Abstract Background Modified tension band fixation has become commonly used for transverse patella fractures. The conventional stainless steel wire provides sufficient stability but may be associated with complications. Objective The study aimed to evaluate the effectiveness of a new modified tension band fixation technique for transverse patella fractures using a nonabsorbable suture. Material and methods We present the result of a prospective series using a nonabsorbable suture (FiberWire) for transverse patella fractures. The mean follow-up period totaled 12 months. A total of 16 patients were evaluated by radiographic and clinical review. The postoperative clinical evaluation employed Lysholm and Böstman scores. Result All clinical results on follow-up were good to excellent. Minimal intra-articular joint stepping and further fracture displacement were recorded. No patient needed re-operation, and functional outcomes of the knee were satisfactory. No significant differences were found between the injured and contralateral knee range of motion. No symptomatic implants and skin complications were noted, and all fractures were completed heal within 15 weeks. Conclusion FiberWire provided sufficient stability and reduced postoperative complications. The results proved appropriate, and the technique has merit, as it obviates the need for re-operation.


2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Zhanchao Tan ◽  
Hongzhi Hu ◽  
Xiangtian Deng ◽  
Jian Zhu ◽  
Yanbin Zhu ◽  
...  

Abstract Background Limited information exists on the incidence of postoperative deep venous thromboembolism (DVT) in patients with isolated patella fractures. The objective of this study was to investigate the postoperative incidence and locations of deep venous thrombosis (DVT) of the lower extremity in patients who underwent isolated patella fractures and identify the associated risk factors. Methods Medical data of 716 hospitalized patients was collected. The patients had acute isolated patella fractures and were admitted at the 3rd Hospital of Hebei Medical University between January 1, 2016, and February 31, 2019. All patients met the inclusion criteria. Medical data was collected using the inpatient record system, which included the patient demographics, patient’s bad hobbies, comorbidities, past medical history, fracture and surgery-related factors, hematological biomarkers, total hospital stay, and preoperative stay. Doppler examination was conducted for the diagnosis of DVT. Univariate analyses and multivariate logistic regression analyses were used to identify the independent risk factors. Results Among the 716 patients, DVT was confirmed in 29 cases, indicating an incidence of 4.1%. DVT involved bilateral limbs (injured and uninjured) in one patient (3.4%). DVT involved superficial femoral common vein in 1 case (3.4%), popliteal vein in 6 cases (20.7%), posterior tibial vein in 11 cases (37.9%), and peroneal vein in 11 cases (37.9%). The median of the interval between surgery and diagnosis of DVT was 4.0 days (range, 1.0-8.0 days). Six variables were identified to be independent risk factors for DVT which included age category (> 65 years old), OR, 4.44 (1.34-14.71); arrhythmia, OR, 4.41 (1.20-16.15); intra-operative blood loss, OR, 1.01 (1.00-1.02); preoperative stay (delay of each day), OR, 1.43 (1.15-1.78); surgical duration, OR, 1.04 (1.03-1.06); LDL-C (> 3.37 mmol/L), OR, 2.98 (1.14-7.76). Conclusion Incidence of postoperative DVT in patients with isolated patella fractures is substantial. More attentions should be paid on postoperative DVT prophylaxis in patients with isolated patella fractures. Identification of associated risk factors can help clinicians recognize the risk population, assess the risk of DVT, and develop personalized prophylaxis strategies.


Children ◽  
2021 ◽  
Vol 8 (6) ◽  
pp. 495
Author(s):  
Dror Paley ◽  
Claire E. Shannon ◽  
Monica Nogueira ◽  
Catharina Chiari ◽  
Matthew Harris

Congenital femoral deficiency (CFD) Paley type 1b is characterized by severe bony deformity of the upper femur, extra-articular contractures of the hip, and, delayed ossification of the femoral neck and/or subtrochanteric region. The Systematic Utilitarian Procedure for Extremity Reconstruction of the hip (SUPERhip) procedure for the correction of CFD deformities was developed in 1997. Initially, a non-fixed angle device (rush rod) was used for fixation. Late complications of persistent delayed ossification and recurrent varus deformity occurred. In order to reduce and treat such complications, fixation with a fixed angle device and the off-label use of BMP2 to induce ossification of the un-ossified femoral neck were employed. The purpose of this study is to determine if the use of a fixed angle device, and, BMP2 inserted into a drill hole in the cartilage of the femoral neck, decreases the incidence of these late complications. We retrospectively reviewed 72 SUPERhip procedures performed for Paley type 1b CFD between 1997 and 2012. Due to recurrent varus or persistent delayed ossification of the femoral neck, 34 revision SUPERhip procedures were performed. In total, 106 SUPERhip procedures were studied. Sixty-eight SUPERhips were performed using internal fixation without BMP2, while 38 SUPERhips were performed with both internal fixation and the addition of BMP2. Forty-one were performed using non-fixed angle internal fixation while 65 had fixed angle internal fixation. Fixed angle devices significantly reduced the incidence of recurrent varus compared with non-fixed angle devices. Inserting BMP2 in the femoral neck significantly reduced the incidence of persistent delayed ossification. Using only a fixed angle device but no BMP2 did not reduce the incidence of delayed ossification. The combination of both a fixed angle device and BMP2 reduced the incidence of recurrent coxa vara and persistent delayed ossification of the femoral neck. The SUPERhip procedure corrects the pathoanatomy of the proximal femur in CFD Paley type 1b but is associated with a very high risk of recurrence of coxa vara and persistence of femoral neck delayed ossification, unless, a fixed angle internal fixation device is used to prevent recurrent coxa vara and BMP2 is used to induce ossification of the femoral neck.


Sign in / Sign up

Export Citation Format

Share Document