scholarly journals EEG Based Biometric Identification Using Correlation and MLPNN Models

Author(s):  
T Waili ◽  
Md Gapar Md Johar ◽  
K. A. Sidek ◽  
N. S. H. Mohd Nor ◽  
H. Yaacob ◽  
...  

<p class="0abstract">This study investigates the capability of electroencephalogram (EEG) signals to be used for biometric identification. In the context of biometric, recently, researchers have been focusing more on biomedical signals to substitute the biometric modalities that are being used nowadays as the signals obtained from our bodies is considered more secure and privacy-compliant. The EEG signals of 6 subjects were collected where the subjects were required to undergo two baseline experiments which are, eyes open (EO) and eyes closed (EC). The signals were processed using a 2nd order Butterworth filter to eliminate the unwanted noise in the signals. Then, Daubechies (db8) wavelet was applied to the signals in the feature extraction stage and from there, Power Spectral Density (PSD) of alpha and beta waves was computed. Finally, the correlation model and Multilayer Perceptron Neural Network (MLPNN) was applied to classify the EEG signals of each subject.  Correlation model has yielded great significant difference of coefficient between autocorrelation and cross-correlation where it gives the coefficient value of 1 for autocorrelation and the coefficient value of less than 0.35 for cross-correlation. On the other hand, the MLPNN model gives an accuracy of 75.8% and 71.5% for classification during EO and EC baseline condition respectively. Therefore, these results support the usability of EEG signals in biometric recognition.</p>

Author(s):  
José Humberto Trueba Perdomo ◽  
◽  
Ignacio Herrera Aguilar ◽  
Francesca Gasparini ◽  
◽  
...  

This paper presents a new application for analyzing electroencephalogram (EEG) signals. The signals are pre-filtered through MATLAB's EEGLAB tool. The created application performs a convolution between the original EEG signal and a complex Morlet wavelet. As a final result, the application shows the signal power value and a spectrogram of the convoluted signal. Moreover, the created application compares different EEG channels at the same time, in a fast and straightforward way, through a time and frequency analysis. Finally, the effectiveness of the created application was demonstrated by performing an analysis of the alpha signals of healthy subjects, one signal created by the subject with eyes closed and the other, with which it was compared, was created by the same subject with eyes open. This also served to demonstrate that the power of the alpha band of the closed-eyed signal is higher than the power of the open-eyed signal.


2020 ◽  
Vol 16 ◽  
Author(s):  
Neerja Thukral ◽  
Jaspreet Kaur ◽  
Manoj Malik

Background: Peripheral neuropathy is a major and chronic complication of diabetes mellitus affecting more than 50% of patients suffering from diabetes. There is involvement of both large and small diameter nerve fibres leading to altered somatosensory and motor sensations, thereby causing impaired balance and postural instability. Objective: To assess the effects of exercises on posture and balance in patients suffering from diabetes mellitus. Method: Mean changes in Timed Up and Go test(TUGT), Berg Balance Scale and Postural Sway with eyes open and eyes closed on Balance System were primary outcome measures. RevMan 5.3 software was used for the meta-analyses. Eighteen randomized controlled trials met the selection criteria and were included in the study. All the studies ranked high on PEDro Rating scale. Risk of bias was assessed by Cochrane collaboration tool of risk of bias. Included studies had low risk of bias. Sixteen RCT’s were included for the meta-analysis. Result: Results of meta-analysis showed that there was statistically significant improvement in TUGT with p≤ 0.05 and substantial heterogeneity (I 2 = 84%, p < 0.00001) in experimental group as compared to control group. There was statistically significant difference in Berg Balance Scale scores and heterogeneity of I 2 = 62%, p < 0.00001 and significant changes in postural stability (eyes open heterogeneity of I 2 = 100%, p =0.01 and eyes closed, heteogeneity I 2 = 0%, p =0.01). Sensitivity analysis causes change in heterogeneity. Conclusion: It can be concluded that various exercises like balance training, core stability, Tai-Chi, proprioceptive training etc. have a significant effect in improving balance and posture in diabetic neuropathy.


1984 ◽  
Vol 56 (3) ◽  
pp. 607-612 ◽  
Author(s):  
N. Wolkove ◽  
H. Kreisman ◽  
D. Darragh ◽  
C. Cohen ◽  
H. Frank

We studied the effect of transcendental meditation (TM) on breathing using 16 experienced meditators and 16 control subjects. In controls, there was no significant difference in minute ventilation (VE), respiratory pattern, or hypercapnic response, whether breathing with eyes open-awake (CA), or with eyes closed-relaxing (CR). In meditators, VE decreased significantly during quiet breathing from 14.0 +/- 0.7 1/min with eyes open-awake (MA) to 12.4 +/- 0.6 1/min during meditation (MM) (P less than 0.02). The change in VE during meditation was due to a decrease in tidal volume (VT) resulting from a shortened inspiratory time (TI). Meditation was associated with a decreased response to progressive hypercapnia from 3.7 +/- 0.4 to 2.5 +/- 0.21 X min-1 X Torr-1 during MA and MM trials, respectively (P less than 0.01). During meditation VT was smaller at a given alveolar PCO2 than during MA studies because of a decrease in mean inspiratory flow rate (VT/TI). These observations suggest that an alteration in wakefulness, more subtle than sleep or the unconscious state, can significantly affect the chemical and neural regulation of breathing.


2019 ◽  
Author(s):  
Nadine Farnes ◽  
Bjørn E. Juel ◽  
André S. Nilsen ◽  
Luis G. Romundstad ◽  
Johan F. Storm

AbstractObjectiveHow and to what extent electrical brain activity is affected in pharmacologically altered states of consciousness, where it is mainly the phenomenological content rather than the level of consciousness that is altered, is not well understood. An example is the moderately psychedelic state caused by low doses of ketamine. Therefore, we investigated whether and how measures of evoked and spontaneous electroencephalographic (EEG) signal diversity are altered by sub-anaesthetic levels of ketamine compared to normal wakefulness, and how these measures relate to subjective assessments of consciousness.MethodsHigh-density electroencephalography (EEG, 62 channels) was used to record spontaneous brain activity and responses evoked by transcranial magnetic stimulation (TMS) in 10 healthy volunteers before and after administration of sub-anaesthetic doses of ketamine in an open-label within-subject design. Evoked signal diversity was assessed using the perturbational complexity index (PCI), calculated from the global EEG responses to local TMS perturbations. Signal diversity of spontaneous EEG, with eyes open and eyes closed, was assessed by Lempel Ziv complexity (LZc), amplitude coalition entropy (ACE), and synchrony coalition entropy (SCE).ResultsAlthough no significant difference was found in the index of TMS-evoked complexity (PCI) between the sub-anaesthetic ketamine condition and normal wakefulness, all the three measures of spontaneous EEG signal diversity showed significantly increased values in the sub-anaesthetic ketamine condition. This increase in signal diversity also correlated with subjective assessment of altered states of consciousness. Moreover, spontaneous signal diversity was significantly higher when participants had eyes open compared to eyes closed, both during normal wakefulness and during influence of sub-anaesthetic ketamine doses.ConclusionThe results suggest that PCI and spontaneous signal diversity may be complementary and potentially measure different aspects of consciousness. Thus, our results seem compatible with PCI being indicative of the brain’s ability to sustain consciousness, as indicated by previous research, while it is possible that spontaneous EEG signal diversity may be indicative of the complexity of conscious content. The observed sensitivity of the latter measures to visual input seems to support such an interpretation. Thus, sub-anaesthetic ketamine may increase the complexity of both the conscious content (experience) and the brain activity underlying it, while the level, degree, or general capacity of consciousness remains largely unaffected.


Author(s):  
Sude Pehlivan ◽  
Yalcin Isler

Surface EEG measurements that can be performed in hospitals and laboratories have reached a wearable and portable level with the development of today's technologies. Artificial intelligence-assisted brain-computer interface (BCI) systems play an important role in individuals with disabilities to process EEG signals and interact with the outside world. In particular, the research is becoming widespread to meet the basic needs of individuals in need of home care with an increasing population. In this study, it is aimed to design the BCI system that will detect the hunger and satiety status of the people on the computer platform through EEG measurements. In this context, a database was created by recording EEG signals with eyes open and eyes closed by 20 healthy participants in the first stage of the study. The noise of the EEG signal is eliminated by using a low pass, high pass, and notch filters. In the classification, using Wavelet Packet Transform (WPT) with Coiflet 1 and Daubechies 4 wavelets, 77.50% accuracy was achieved in eyes closed measurement, and 81% in eyes open measurement.


2022 ◽  
pp. 1-10
Author(s):  
Audrey Parent ◽  
Laurent Ballaz ◽  
Bahare Samadi ◽  
Maria Vocos, pht ◽  
Alain Steve Comtois ◽  
...  

Background: Myotonic dystrophy type 1 (DM1) is characterized by progressive and predominantly distal muscle atrophy and myotonia. Gait and balance impairments, resulting in falls, are frequently reported in this population. However, the extent to which individuals with DM1 rely more on a specific sensory system for balance than asymptomatic individuals (AI) is unknown. Objective: Evaluate postural control performance in individuals with DM1 and its dependence on vision compared to AI. Methods: 20 participants with DM1, divided into two groups based on their diagnosis, i.e. adult and congenital phenotype, and 12 AI participants were recruited. Quiet standing postural control was assessed in two visual conditions: eyes-open and eyes-closed. The outcomes measures were center of pressure (CoP) mean velocity, CoP range of displacement in anteroposterior and mediolateral axis, and the 95% confidence ellipse’s surface. Friedman and Kruskal-Wallis analysis of variance were used to compare outcomes between conditions and groups, respectively. Results: Significant group effect and condition effect were observed on postural control performance. No significant difference was observed between the two DM1 groups. The significant differences observed between the AI group and the two DM1 groups in the eyes-open condition were also observed in the eyes-closed condition. Conclusions: The result revealed poorer postural control performance in people with DM1 compared to AI. The DM1 group also showed similar decrease in performance than AI in eyes-closed condition, suggesting no excessive visual dependency.


2020 ◽  
Vol 10 (10) ◽  
pp. 3532
Author(s):  
Jesús Jaime Moreno Escobar ◽  
Oswaldo Morales Matamoros ◽  
Ricardo Tejeida Padilla ◽  
Ixchel Lina Reyes ◽  
Liliana Chanona Hernández ◽  
...  

This work presents the HSS-Cognitive project, which is a Healthcare Smart System that can be applied in measuring the efficiency of any therapy where neuronal interaction gives a trace whether the therapy is efficient or not, using mathematical tools. The artificial intelligence of the project underlies in the understanding of brain signals or Electroencephalogram (EEG) by means of the determination of the Power Spectral Density (PSD) over all the EEG bands in order to estimate how efficient was a therapy. Our project HSS-Cognitive was applied, recording the EEG signals from two patients treated for 8 min in a dolphin tank, measuring their activity in five experiments and for 6 min measuring their activity in a pool without dolphin in four experiments. After applying our TEA (Therapeutic Efficiency Assessment) metric for patient 1, we found that this patient had gone from having relaxation states regardless of the dolphin to attention states when the dolphin was presented. For patient 2, we found that he had maintained attention states regardless of the dolphin, that is, the DAT (Dolphin Assisted Therapy) did not have a significant effect in this patient, perhaps because he had a surgery last year in order to remove a tumor, having impact on the DAT effectiveness. However, patient 2 presented the best efficiency when doing physical therapy led by a therapist in a pool without dolphins around him. According to our findings, we concluded that our Brain-Inspired Healthcare Smart System can be considered a reliable tool for measuring the efficiency of a dolphin-assisted therapy and not only for therapist or medical doctors but also for researchers in neurosciences.


1998 ◽  
Vol 80 (3) ◽  
pp. 1211-1221 ◽  
Author(s):  
David A. Winter ◽  
Aftab E. Patla ◽  
Francois Prince ◽  
Milad Ishac ◽  
Krystyna Gielo-Perczak

Winter, David A., Aftab E. Patla, Francois Prince, Milad Ishac, and Krystyna Gielo-Perczak. Stiffness control of balance in quiet standing. J. Neurophysiol. 80: 1211–1221, 1998. Our goal was to provide some insights into how the CNS controls and maintains an upright standing posture, which is an integral part of activities of daily living. Although researchers have used simple performance measures of maintenance of this posture quite effectively in clinical decision making, the mechanisms and control principles involved have not been clear. We propose a relatively simple control scheme for regulation of upright posture that provides almost instantaneous corrective response and reduces the operating demands on the CNS. The analytic model is derived and experimentally validated. A stiffness model was developed for quiet standing. The model assumes that muscles act as springs to cause the center-of-pressure (COP) to move in phase with the center-of-mass (COM) as the body sways about some desired position. In the sagittal plane this stiffness control exists at the ankle plantarflexors, in the frontal plane by the hip abductors/adductors. On the basis of observations that the COP-COM error signal continuously oscillates, it is evident that the inverted pendulum model is severely underdamped, approaching the undamped condition. The spectrum of this error signal is seen to match that of a tuned mass, spring, damper system, and a curve fit of this “tuned circuit” yields ωn the undamped natural frequency of the system. The effective stiffness of the system, K e , is then estimated from K e = Iω2 n, and the damping B is estimated from B = BW × I, where BW is the bandwidth of the tuned response (in rad/s), and I is the moment of inertia of the body about the ankle joint. Ten adult subjects were assessed while standing quietly at three stance widths: 50% hip-to-hip distance, 100 and 150%. Subjects stood for 2 min in each position with eyes open; the 100% stance width was repeated with eyes closed. In all trials and in both planes, the COP oscillated virtually in phase (within 6 ms) with COM, which was predicted by a simple 0th order spring model. Sway amplitude decreased as stance width increased, and K e increased with stance width. A stiffness model would predict sway to vary as K −0.5 e . The experimental results were close to this prediction: sway was proportional to K −0.55 e . Reactive control of balance was not evident for several reasons. The visual system does not appear to contribute because no significant difference between eyes open and eyes closed results was found at 100% stance width. Vestibular (otolith) and joint proprioceptive reactive control were discounted because the necessary head accelerations, joint displacements, and velocities were well below reported thresholds. Besides, any reactive control would predict that COP would considerably lag (150–250 ms) behind the COM. Because the average COP was only 4 ms delayed behind the COM, reactive control was not evident; this small delay was accounted for by the damping in the tuned mechanical system.


Scientifica ◽  
2016 ◽  
Vol 2016 ◽  
pp. 1-4 ◽  
Author(s):  
Hossein Talebi ◽  
Mohammad Taghi Karimi ◽  
Seyed Hamid Reza Abtahi ◽  
Niloofar Fereshtenejad

Aims. Vestibular system is indicated as one of the most important sensors responsible for static and dynamic postural control. In this study, we evaluated static balance in patients with unilateral vestibular impairments.Materials and Methods. We compared static balance control using Kistler force plate platform between 10 patients with unilateral vestibular impairments and 20 normal counterparts in the same sex ratio and age limits (50±7). We evaluated excursion and velocity of center of pressure (COP) and path length in anteroposterior (AP) and mediolateral (ML) planes with eyes open and with eyes closed.Results. There was no significant difference between COP excursions in ML and AP planes between both groups with eyes open and eyes closed (pvalue > 0.05). In contrast, the difference between velocity and path length of COP in the mentioned planes was significant between both groups with eyes open and eyes closed (pvalue < 0.05).Conclusions. The present study showed the static instability and balance of patients with vestibular impairments indicated by the abnormal characteristics of body balance.


Sign in / Sign up

Export Citation Format

Share Document