Seismical Protection Properties of High Damping Rubber Bearing and Lead Rubber Bearing Base Isolation Systems for Multi-Storey RC Buildings

2012 ◽  
Vol 234 ◽  
pp. 90-95 ◽  
Author(s):  
Donato Cancellara ◽  
Fabio de Angelis

In the present paper two different base isolation systems, designed and verified according to the european seismic code (EC2 and EC8), are compared for evaluating the behaviour of a base isolated building, highly irregular in plan, in presence of a seismic excitation. The devices adopted for realizing the different base isolation systems are the High Damping Rubber Bearing (HDRB) and the Lead Rubber Bearing (LRB) both of them actuated in parallel with a Friction Slider (FS). A dynamic nonlinear analysis for a three-dimensional base isolated structure has been performed. Recorded accelerograms for bi-directional ground motions, compatible with the reference elastic response spectrum for each limit state have been used for a more realistic evaluation of the seismic response of the structure and a more realistic comparative analysis between the base isolated structure with the different considered base isolation systems and the traditional fixed base structure.

2018 ◽  
Vol 1 (18) ◽  
Author(s):  
Barghlame Hadi ◽  
Gavgani Hojjat Hashempour

Base isolation systems are among the most successful and widely applied methods of mitigatingstructural vibration and damage during seismic events. These systems have been installed in numerousfull-scale structures all around. There are three principal types of base isolators: Lead Rubber Bearing(LRB), High Damping Rubber Bearing (HDRB), and Friction Pendulum System (FPS). It is necessaryto extensively examine the response of different LRB isolators—by combining them with re-centeringand damping properties for isolated steel frame buildings experiencing several NF ground motions. Thepresent research uses comparative-descriptive methodology and application in terms of objectives. Thedata needed for the study were collected using library references and through reviewing related studiesconducted in the past in the same field.Results of the current comparative investigation indicated significant reductions in the storey drift,shear, and acceleration and increment in the storey displacement. According to the findings of thecurrent study, base isolators provide flexibility to massive structures against earthquakes. Thesestructures are situated on rigid soils. Moreover, base isolation was found to be the most effective incontrolling the response of the structures during earthquakes. Finally, shear, storey drift, and storeydisplacement reduce due to the use of base isolators as compared to the fixed-base structure.


2020 ◽  
Vol 6 (2) ◽  
pp. 181-194
Author(s):  
Syahnandito ◽  
Reni Suryanita ◽  
Ridwan

Salah satu cara yang dapat dilakukan adalah menggunakan peredam beban gempa dengan sistem isolasi dasar (base isolation system). Penggunaan base isolation system  pada bangunan dapat mengisolasi perambatan getaran akibat gempa dari tanah ke struktur atas bangunan menggunakan komponen berbahan karet. Tujuan penelitian ini adalah untuk menganalisis pengaruh penggunaan sistem isolasi dasar berupa High Damping Rubber Bearing pada periode dan gaya geser dasar  struktur beton bertulang. Objek penelitian adalah bangunan hotel 15 lantai dengan ketinggian 62,9 m. Penelitian diawali dengan pemodelan struktur menggunakan aplikasi ETABS v2016 sehingga didapatkan periode dan gaya geser dasar struktur fixbase. Tahap selanjutnya memberikan gaya pada model struktur dengan isolasi dasar High Dumper Rubber Bearing sehingga didapatkan periode dan gaya geser dasar struktur dengan base isolator. Hasil analisis pada struktur fixbase didapatkan periode sebesar 4,212 detik, dengan gaya geser dasar didapatkan sebesar 1470,725 ton. Sedangkan hasil analisis pada struktur dengan base isolator didapatkan periode sebesar 5,500 detik, dengan gaya geser dasar didapatkan sebesar 1286,071 ton. Maka dapat disimpulkan bahwa pada struktur dengan base isolator terjadi peningkatan periode sebesar 30,58 %, sedangkan gaya geser dasar terjadi penurunan 12,56 %.


Author(s):  
Jun-Ping Pu ◽  
C. S. Tsai ◽  
Jian-Fa Huang ◽  
Bo-Jen Chen ◽  
Yao-Min Fang

In recent years, many studies on base isolation strategies and devices have been developed and applied in U. S. A., Europe, Japan, and New Zealand. The high damping rubber bearing belongs to one kind of the earthquake-proof ideas of base isolation technologies. The installation of high damping rubber bearings can lengthen the natural period of a building and simultaneously reduce the earthquake-induced energy trying to impart to the building. The objective of this paper is to investigate the base isolation effect of high damping rubber bearings. The uniaxial, biaxial, and triaxial shaking table tests were performed to study the seismic behavior of a 0.4-scale three-story isolated steel structure in the National Center for Research on Earthquake Engineering in Taiwan. The experimental and analytical results show that the nonlinear mechanical characteristics of the high damping rubber bearings can be reasonably simulated.


2014 ◽  
Vol 7 (6) ◽  
pp. 1141-1169
Author(s):  
Patrick L.Y. Tiong ◽  
Azlan Adnan ◽  
Ahmad B.A. Rahman ◽  
Abdul K. Mirasa

2014 ◽  
Vol 19 (Supplement_1) ◽  
pp. S33-S49 ◽  
Author(s):  
A. B. M. Saiful Islam ◽  
Mohd Zamin Jumaat ◽  
Raja Hussain ◽  
Md Ashraful Alam

Base isolation incorporation has moved towards a popular technology in the seismic vulnerable regions. The system mitigates lateral action of tremor hazard providing flexibility of structures. Implementing base isolation on buildings in the soil and seismic condition of medium risk seismicity is currently an important issue. A thorough investigation is of burning need for buildings to be incorporated with base isolator and to carry out dynamic analysis. The study provides incorporation of rubber-steel bearings and focuses on the structural changes. Designs of base isolation bearings are performed along with structural viability check. Lead rubber bearing (LRB) and high damping rubber bearing (HDRB) have been inserted on the corresponding structural bases. In finite-element approach, link element simulates the bearing. Bi-linear hysteretic behaviour is presented for LRB and equivalent linear model simulated HDRB. Linear static, free vibration and dynamic frequency-domain analyses are performed for both isolated and non-isolated buildings under bidirectional site-specific earthquake. The study reveals that for multi-storey buildings, isolation can drastically reduce seismic responses. Furthermore, flexibility of buildings predicts some structural savings for reduced responses. Good agreement has been achieved through rapid solution in frequency-domain approach. In medium risk earthquake-prone area, rubber-steel bearing isolators can be beneficially inserted.


2016 ◽  
Vol 846 ◽  
pp. 114-119
Author(s):  
Arati Pokhrel ◽  
Jian Chun Li ◽  
Yan Cheng Li ◽  
Nicos Maksis ◽  
Yang Yu

Due to the fact that safety is the major concern for civil structures in a seismic active zone, it has always been a challenge for structural engineers to protect structures from earthquake. During past several decades base isolation technique has become more and more popular in the field of seismic protection which can be adopted for new structures as well as the retrofit of existing structures. The objective of this study is to evaluate the behaviours of the building with different seismic isolation systems in terms of roof acceleration, elastic base shear and inter-storey drift under four benchmark earthquakes, namely, El Centro, Northridge, Hachinohe and Kobe earthquakes. Firstly, the design of base isolation systems, i.e. lead rubber bearing (LRB) and friction pendulum bearing (FPB) for five storey RC building was introduced in detail. The non-linear time history analysis was performed in order to determine the structural responses whereas Bouc-Wen Model of hysteresis was adopted for modelling the bilinear behaviour of the bearings. Both isolation systems increase the fundamental period of structures and reduces the spectral acceleration, and hence reduces the lateral force cause by earthquake in the structures, resulting in significant improvement in building performance; however the Lead Rubber Bearing provided the best reduction in elastic base shear and inter-storey drift (at first floor) for most of the benchmark earthquakes. For the adopted bearing characteristics, FPB provided the low isolator displacement.