The Electric Field Analysis of the Warm Dielectric HTS Power Cable

2013 ◽  
Vol 347-350 ◽  
pp. 1276-1282
Author(s):  
Yu Ping Teng ◽  
Shao Tao Dai ◽  
Li Ye Xiao ◽  
Dong Zhang ◽  
Bing Song Cheng

The 75 m/1.5 kA AC high-temperature superconducting cable(75 m HTS cable) and the 360 m/10 kA DC HTS power cable (10 kA HTS cable), which are supported by Chinese State 863 projects, are both of the demonstration projects facing to industrialization application. The characteristic in structure of warm dielectric (WD) insulated HTS cable is introduced. The electric field distribution characteristic at the cryogenic envelope body, the end-point of metallic shield layer at the end of the HTS cable and the connection sections are analyzed; the controlling method for electric field stress is introduced; there is serious concentration of electric field both in the termination and the connection sections between the termination and the cryogenic envelope. It is difficult to calculate the electric field of the part with irregular or special structure by resolution analytical methods, and the numerical analysis method is effective to analyze the electric field of the shaped structural part for HTS cable. The electric analysis, simulation, the design and processing of insulation for the two cables are finished based upon these two cables run well by now.

2012 ◽  
Vol 516-517 ◽  
pp. 1517-1520
Author(s):  
Jian Xun Hu ◽  
Gong Da Zhang ◽  
Hong Yu Zhang ◽  
Xiao Qin Zhang

Using the finite element analysis, this work analyzed the electric field distribution of 220kV transmission steel tower with double-circuit and composite material transmission tower with the same size, and compared the electric field effect of two materials transmission tower for surroundings. And this work compared the vertical and axial electric field distribution along transmission line of the two materials transmission tower. The results indicate the composite material tower can improve the environment of electric field near the transmission lines.


2010 ◽  
Vol 43 ◽  
pp. 546-550
Author(s):  
Kang Huang ◽  
Gen Qian ◽  
Qing Song Liang ◽  
Yu Feng Qu

The structure of current micro-machined gyroscope result in detection error and processing difficulty, which can be reduced by redesigning the structure such as a new type researched here to enhance the accuracy..The new structure for gyroscope and the method of driving force calculating for it is introduced in this paper. A 3D micro-machined gyroscope model has been built through CAD software, while finite model through CAE software. Besides, the driving structure has been analyzed to gain the size of driving force and electric-field distribution.


2014 ◽  
Vol 521 ◽  
pp. 321-329
Author(s):  
Quan Zhou ◽  
Li Tu ◽  
Rui Bie ◽  
Dong Feng ◽  
You Ping Fan

Currently, there is little experience about design of the 1-tower-double-circuit DC transmission lines. But the electromagnetic field distribution under its lines is complicated. In order to study the nominal electric field distribution of 1-tower-double-circuit DC transmission lines under different situations and a variety of operating conditions, the currents with analytical solutions are used to simulate the discrete or uneven distributed continuous charge. In the works within an acceptable range, the linear equations are built to solve simulation charge according to the electromagnetic theory. And ground nominal electric field of 1-tower-double-circuit DC transmission lines is calculated. The nominal electric field distribution extreme value extreme under different arrangements and nominal electric field distribution under a variety of operating conditions are analyzed comparatively. In this paper, the results show that the arrangements of lines have effects on the distribution characteristics of nominal electric field in normal condition. When monopole or bipolar or the bipolar of one line doesnt work, the change of nominal electric field is pronounced, but their extremes reduce.


2014 ◽  
Vol 1008-1009 ◽  
pp. 598-602
Author(s):  
Shu Min Sun ◽  
Yan Cheng ◽  
Xin Su

±1000kV DC wall bushing is a complex insulation system working in different conditions, such as DC, AC and polarity reversal. No matter what kind of conditions, the space charge effects on the electric field distribution of the bushing are remarkable. A finite element model for ±1000kV DC wall bushing is established based on space charge theory, to analyze the electric field distribution in different conditions, especially when polarity reversal occurs. The research results provide useful references for the electric field analysis and insulation optimization of UHV (ultra high voltage) DC wall bushings.


2011 ◽  
Vol 291-294 ◽  
pp. 2352-2355
Author(s):  
Cheng Lin Liu ◽  
Ze Sun ◽  
Yun Zhao ◽  
Xing Fu Song ◽  
Gui Min Lu ◽  
...  

The electric field distribution was the main factor affecting on the current efficiency of electrolysis cell. So, the electric field distribution of magnesium electrolysis cell was studied to improve the current efficiency by two of main finite element softwares, COMSOL and ANSYS. The electric field distribution and its trends with the electrolyte change from 1.25m to 1.40m were calculated by using the two softwares. Form the results, the characteristics of COMSOL and ANSYS can be obtained. The conclusions of the paper will provided a significant reference for choose the appropriate software in practice process.


Cryogenics ◽  
2014 ◽  
Vol 63 ◽  
pp. 215-218 ◽  
Author(s):  
Jae-Sang Hwang ◽  
Hee-Suk Ryoo ◽  
Ja-Yoon Koo ◽  
Jeon-Wook Cho ◽  
Bang-Wook Lee

2015 ◽  
Vol 135 (12) ◽  
pp. 731-736
Author(s):  
Takuma Terakura ◽  
Kei Takano ◽  
Takanori Yasuoka ◽  
Shigekazu Mori ◽  
Osamu Hosokawa ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document