Different Finite Element Software on Electric Field Analysis of Magnesium Electrolysis Cell

2011 ◽  
Vol 291-294 ◽  
pp. 2352-2355
Author(s):  
Cheng Lin Liu ◽  
Ze Sun ◽  
Yun Zhao ◽  
Xing Fu Song ◽  
Gui Min Lu ◽  
...  

The electric field distribution was the main factor affecting on the current efficiency of electrolysis cell. So, the electric field distribution of magnesium electrolysis cell was studied to improve the current efficiency by two of main finite element softwares, COMSOL and ANSYS. The electric field distribution and its trends with the electrolyte change from 1.25m to 1.40m were calculated by using the two softwares. Form the results, the characteristics of COMSOL and ANSYS can be obtained. The conclusions of the paper will provided a significant reference for choose the appropriate software in practice process.

2012 ◽  
Vol 516-517 ◽  
pp. 1517-1520
Author(s):  
Jian Xun Hu ◽  
Gong Da Zhang ◽  
Hong Yu Zhang ◽  
Xiao Qin Zhang

Using the finite element analysis, this work analyzed the electric field distribution of 220kV transmission steel tower with double-circuit and composite material transmission tower with the same size, and compared the electric field effect of two materials transmission tower for surroundings. And this work compared the vertical and axial electric field distribution along transmission line of the two materials transmission tower. The results indicate the composite material tower can improve the environment of electric field near the transmission lines.


2010 ◽  
Vol 43 ◽  
pp. 546-550
Author(s):  
Kang Huang ◽  
Gen Qian ◽  
Qing Song Liang ◽  
Yu Feng Qu

The structure of current micro-machined gyroscope result in detection error and processing difficulty, which can be reduced by redesigning the structure such as a new type researched here to enhance the accuracy..The new structure for gyroscope and the method of driving force calculating for it is introduced in this paper. A 3D micro-machined gyroscope model has been built through CAD software, while finite model through CAE software. Besides, the driving structure has been analyzed to gain the size of driving force and electric-field distribution.


2014 ◽  
Vol 521 ◽  
pp. 321-329
Author(s):  
Quan Zhou ◽  
Li Tu ◽  
Rui Bie ◽  
Dong Feng ◽  
You Ping Fan

Currently, there is little experience about design of the 1-tower-double-circuit DC transmission lines. But the electromagnetic field distribution under its lines is complicated. In order to study the nominal electric field distribution of 1-tower-double-circuit DC transmission lines under different situations and a variety of operating conditions, the currents with analytical solutions are used to simulate the discrete or uneven distributed continuous charge. In the works within an acceptable range, the linear equations are built to solve simulation charge according to the electromagnetic theory. And ground nominal electric field of 1-tower-double-circuit DC transmission lines is calculated. The nominal electric field distribution extreme value extreme under different arrangements and nominal electric field distribution under a variety of operating conditions are analyzed comparatively. In this paper, the results show that the arrangements of lines have effects on the distribution characteristics of nominal electric field in normal condition. When monopole or bipolar or the bipolar of one line doesnt work, the change of nominal electric field is pronounced, but their extremes reduce.


2014 ◽  
Vol 1008-1009 ◽  
pp. 598-602
Author(s):  
Shu Min Sun ◽  
Yan Cheng ◽  
Xin Su

±1000kV DC wall bushing is a complex insulation system working in different conditions, such as DC, AC and polarity reversal. No matter what kind of conditions, the space charge effects on the electric field distribution of the bushing are remarkable. A finite element model for ±1000kV DC wall bushing is established based on space charge theory, to analyze the electric field distribution in different conditions, especially when polarity reversal occurs. The research results provide useful references for the electric field analysis and insulation optimization of UHV (ultra high voltage) DC wall bushings.


2011 ◽  
Vol 268-270 ◽  
pp. 412-417 ◽  
Author(s):  
Ferhat Tighilt

The voltage and electric field distribution in an arrester are very important for its long operation 15 kV with and without pollution. In order to clarify the influence of pollution severity conditions on metal oxide surge arrester, the finite element method (FEM) compilation of the voltage distribution in the ZnO column varistors under different pollution layer conductivity (200 μS, 70μS, 20μS) and clean was employed using the FEMLAB package.


2021 ◽  
Vol 105 ◽  
pp. 221-227
Author(s):  
Hui Ling Wang ◽  
Chun Li Cai

The working principle of ring capacitance sensor is introduced, that is capacitance fringe effect. Finite element model is established through the Hybrid-Trefftz algorithm. Electric field analysis and simulation calculation of different sensor model are done with the finite element software ANSYS, and the optimal structure combination is obtained. And followed the example of optimal structure, the relation of dielectric constant and electric field intensity were given. The result of simulation shows the most direct and the most important two parameters that affect the sensor performance in the design of the ring capacitance sensor are the two electrodes spacing and the length. The dielectric constant of measured medium is smaller, the intensity of electric field intensity is greater. The simulation for subsequent product design has a good theoretical guidance.


Sign in / Sign up

Export Citation Format

Share Document