A Case Study on the Verification of Passive Office Energy Performance Comparing Actual Energy Consumption to Simulation Result

2013 ◽  
Vol 361-363 ◽  
pp. 427-430 ◽  
Author(s):  
Young Sun Ko ◽  
Sang Tae No

The objective of this study is to verify energy performance of passive office building compared to existing building using computer simulation tool, EnergyPlus. S building was selected as a passive office building, which is the first passive office building in KOREA, and the building satisfy the passive house standard. The annual energy consumption data were compared to the heating and cooling load result of EnergyPlus, to verify simulation accuracy. The conditions of existing building were selected from Korean envelope standard and the categories of the conditions are the insulation thickness and glazing composition. As a result, the passive office showed 28% reduced energy consumption, compared to the existing building, with ordinary envelope under Korean building envelope standard.

2018 ◽  
Vol 22 (Suppl. 5) ◽  
pp. 1499-1509
Author(s):  
Miomir Vasov ◽  
Jelena Stevanovic ◽  
Veliborka Bogdanovic ◽  
Marko Ignjatovic ◽  
Dusan Randjelovic

Buildings are one of the biggest energy consumers in urban environments, so its efficient use represents a constant challenge. In public objects and households, a large part of the energy is used for heating and cooling. The orientation of the object, as well as the overall heat transfer coefficient (U-value) of transparent and non-transparent parts of the envelope, can have a significant impact on building energy needs. In this paper, analysis of the influence of different orientations, U-values of envelope elements, and size of windows on annual heating and cooling energy for an office building in city of Nis, Serbia, is presented. Model of the building was made in the Google SketchUp software, while the results of energy performance were obtained using EnergyPlus and jEplus, taking into ac-count the parameters of thermal comfort and climatic data for the area of city of Nis. Obtained results showed that, for varied parameters, the maximum difference in annual heating energy is 15129.4 kWh, i. e per m2 27.75 kWh/m2, while the maximum difference in annual cooling energy is 14356.1 kWh, i. e per m2 26.33 kWh/m2. Considering that differences in energy consumption are significant, analysis of these parameters in the early stage of design process can affect on increase of building energy efficiency.


2021 ◽  
Vol 312 ◽  
pp. 06003
Author(s):  
Franz Bianco Mauthe Degerfeld ◽  
Ilaria Ballarini ◽  
Giovanna De Luca ◽  
Vincenzo Corrado

The EN ISO 52016-1 standard presents a new simplified dynamic calculation procedure, whose aim is to provide an accurate energy performance assessment without excessively increasing the number of data required. The Italian National Annex to EN ISO 52016-1, currently under development, provides some improvements to the hourly calculation method; despite many works can be found in literature on the hourly model of EN ISO 52016-1, the National Annexes application has not been sufficiently analysed yet. The aim of the present work is to assess the main improvements introduced by the Italian National Annex and to compare the main results, in terms of energy need for space heating and cooling. To this purpose, an existing building representative of the Italian office building stock in Northern Italy was selected as a case study. The energy simulations were carried out considering both continuous and reduced operation of the HVAC systems. The options specified in the Italian National Annex were firstly applied one by one, and then all together. The variation of the energy need compared to the international base procedure is finally quantified. For the premises and the scope above discussed, the present work is intended to enhance the standardisation activity towards the adoption of more accurate and trustable calculation methods of the building energy performance.


Energies ◽  
2020 ◽  
Vol 13 (8) ◽  
pp. 1968 ◽  
Author(s):  
Marek Borowski ◽  
Piotr Mazur ◽  
Sławosz Kleszcz ◽  
Klaudia Zwolińska

The energy consumption of buildings is very important for both economic and environmental reasons. Newly built buildings are characterized by higher insulation and airtightness of the building envelope, and are additionally equipped with technologies that minimize energy consumption in order to meet legal requirements. In existing buildings, the modernization process should be properly planned, taking into account available technologies and implementation possibilities. Hotel buildings are characterized by a large variability of energy demand, both on a daily and a yearly basis. Monitoring systems, therefore, provide the necessary information needed for proper energy management in the building. This article presents an energy analysis of the Turówka hotel located in Wieliczka (southern Poland). The historical hotel facility is being modernized as part of the project to adapt the building to the requirements of a sustainable building. The modernization proposal includes a trigeneration system with a multifunctional reverse regenerator and control module using neural algorithms. The main purpose is to improve the energy efficiency of the building and adapt it to the requirements of low-energy buildings. The implementation of a monitoring system enables energy consumption to be reduced and improves the energy performance of the building, especially through using energy management systems and control modules. The proposed retrofit solution considers the high energy consumption, structure of the energy demand, and limits of retrofit intervention on façades.


2019 ◽  
Vol 9 (7) ◽  
pp. 1285 ◽  
Author(s):  
José D. Silvestre ◽  
André M. P. Castelo ◽  
José J. B. C. Silva ◽  
Jorge M. C. L. de Brito ◽  
Manuel D. Pinheiro

This paper analyses the environmental, energy, and economic performances of the External Thermal Insulation Composite System (ETICS) using agglomerated insulation cork board (ICB) or expanded polystyrene (EPS) as insulation material applied in the energetic renovation of the building envelope during a 50-year study period. A comparison between ETICS using ICB and EPS, for the same time horizon, is also presented. The environmental balance is based on “Cradle to Cradle” (C2C) Life Cycle Assessment (LCA), focusing on the carbon footprint and consumption of nonrenewable primary energy (PE-NRe). The characteristics of these products in terms of thermal insulation, the increased energy performance provided by their installation for retrofit of the buildings’ envelope, and the resulting energy savings are considered in the energy balance. The estimation of the C2C carbon and PE-NRe saved is considered in the final balance between the energy and environmental performances. ETICS with ICB is environmentally advantageous both in terms of carbon footprint and of PE-NRe. In fact, the production stage of ICB is less polluting, while EPS requires lower energy consumption to fulfil the heating and cooling needs of a flat, due to its lower U-Value, and its lower acquisition cost results in a lower C2C cost. Comparing both ETICS’ alternatives with reference solutions, it was found that the latter only perform better in the economic dimension, and only for an energy consumption to fulfil less than 25% of the heating and cooling needs. This paper represents an advance to the current state-of-the-art by including all the life-cycle stages and dimensions of the LCA in the analysis of solutions for energy renovation of building envelopes.


2019 ◽  
Vol 111 ◽  
pp. 03052 ◽  
Author(s):  
Mohammed Khalaf ◽  
Touraj Ashrafian ◽  
Cem Demirci

The energy conversations methods and techniques take a significant role in the energy performance of the buildings. Façade and shading systems are in continuous development, and recent studies are showing the importance of implementation of such systems to reduce energy consumption and enhance the effectiveness of the building performance. School buildings are mostly being used during daytime, hence, require active use of sunlight. A measure that is taken on a school building envelope can prevent overheating and overcooling and reduce the heating and cooling energy consumption but at the same time can increase the lighting energy consumption vice versa. Thus, it is necessary to optimise the energy required for climatisation of a building with lighting energy demand. The main aim of the paper is to provide analysis for façade and shading systems applied to a school building and study the effectiveness of it on energy consumption and conservation. The case study for this paper is a typical building project designed to be located in Istanbul, Turkey and has a traditional façade system which is clear double layer windows without any shading devices. The analyses of the energy efficiency of these systems will be presented. The different glazing types and shading systems alternatives will show the most efficient one to be used as some optimised alternatives for the systems. Findings indicate that proper glazing and shading systems can reduce the needed energy for heating and lightening and thus total energy consumption of a school building significantly.


2019 ◽  
Vol 8 (5) ◽  
pp. 366-390 ◽  
Author(s):  
Phan Anh Nguyen ◽  
Regina Bokel ◽  
Andy van den Dobbelsteen

Purpose Refurbishing houses is considered a key measure to improve the energy efficiency of the built environment. However, little is known about the implementation and outcome of housing renovation for energy upgrades in the Vietnamese practice. The purpose of this paper is to investigate the energy performance of the current housing stock in Vietnam and the potential to reduce energy use in households. Design/methodology/approach The paper is based on a survey with 153 respondents in three major climatic regions of Vietnam. The survey focusses on building characteristics, environmental performance, energy performance and refurbishment activities. Data collected from the survey were statistically analysed to give insight into the current performance of the housing stock and its energy saving potential. Findings This paper concludes that building design and construction, particularly the building envelope, have a significant influence on the occupants’ comfort. However, the energy consumption in houses is not statistically associated with building design and indoor environment. It is suggested that financial status and occupants’ behaviour currently have a strong influence on the household energy use. The survey also showed that refurbishment improves the housing performance, especially if improving the indoor environment was one of the drivers. Originality/value There are very few studies on energy use in households in Vietnam, especially with regards to actual energy consumption. This paper brings insights into the actual energy consumption and reveals the “performance gap” in Vietnamese housing stock.


2019 ◽  
Vol 111 ◽  
pp. 04025
Author(s):  
Paula van den Brom ◽  
Arjen Meijer ◽  
Henk Visscher

Thermal renovations are considered to be an effective measure to reduce residential energy consumption. However, they often result in lower-than-expected energy savings. In this paper, we investigate some parameters that influence the probability on lower-than-expected energy savings. We do this by comparing actual pre- and post-renovation energy consumption of 90,000 houses in the Netherlands. The results of this study confirm that the effect of the parameters differ per renovation measure. For every renovation measure, the energy performance gap post renovation plays a significant role. This implies that the use of actual energy consumption data to determine the potential energy savings could therefore help to reduce the number of renovations resulting in lower-than-expected energy savings. Also, the energy efficiency state of the building pre-renovation plays an important role. One should take into account that renovations of energy inefficient buildings more frequently result in lower-than-expected energy savings than renovations of relatively energy efficient buildings. For the type of house we found that multifamily houses more often result in lower than expected savings when building installations are improved, while single-family houses renovations more frequently result in lower energy savings than expected when the building envelope insulation is improved. These insights can contribute to the decision making process whether or not to take a certain renovation measures, they can also help to manage expectations on housing stock level and individual building level.


2015 ◽  
Vol 19 (3) ◽  
pp. 865-880 ◽  
Author(s):  
Norbert Harmati ◽  
Radomir Folic ◽  
Zoltán Magyar

This paper investigates and analyzes a typical multi-zone office building?s annual energy performance for the location and climate data of central Belgrade. The aim is to evaluate the HVAC system?s and HR unit?s performance in order to conduct the most preferable heating and cooling solution for the typical climate of Belgrade city. The energy performance of four HVAC system types (heat pump - air to air, gas-electricity, electrical and fan coil system) was analyzed, compared and evaluated on a virtual office building model in order to assess the total annual energy performance and to determine the efficiency of the HR unit?s application. Further, the parameters of an energy efficient building envelope, HVAC system, internal loads, building operation schedules and occupancy intervals were implemented into the multi-zone analysis model. The investigation was conducted in EnergyPlus simulation engine using system thermodynamic algorithms and surface/air heat balance modules. The comparison and evaluation of the obtained results was achieved through the conversion of the calculated total energy demand into primary energy. The goal is conduct the most preferable heating and cooling solution (Best Case Scenario) for the climate of Belgrade city and outline major criteria in qualitative enhancement.


2018 ◽  
Vol 10 (12) ◽  
pp. 4494 ◽  
Author(s):  
Fabrizio Amoruso ◽  
Udo Dietrich ◽  
Thorsten Schuetze

Apartments in South Korea have high maintenance costs and an average lifetime of 25 years due to poor construction qualities. The common apartment redevelopment strategy is completely demolishing the neighborhoods and then replacing them with new buildings. However, this research discusses the framework for the refurbishment of an existing building in Seoul using Building Information Modeling (BIM) and parametric tools. The virtual model of an exemplary existing building is constructed in a BIM environment. Parametric software is used to simulate the building’s environmental performance, in order to determine its energy demand for heating and cooling and the indoor comfort. In order to reduce the energy demand for heating and cooling, improve the indoor comfort, generate photovoltaic energy and extend the building’s lifetime, a modular building envelope renovation system is developed. Building simulation results of the improved building envelope are used to quantify the differences with the existing building. The research results illustrate significant improvements in energy performance, comfort and lifetime extension that can be achieved. Furthermore, a guideline for a streamlined building optimization process is provided, that can be transferred and used for the planning and optimization of other building renovation projects.


2020 ◽  
pp. 50-64
Author(s):  
Kuladeep Kumar Sadevi ◽  
Avlokita Agrawal

With the rise in awareness of energy efficient buildings and adoption of mandatory energy conservation codes across the globe, significant change is being observed in the way the buildings are designed. With the launch of Energy Conservation Building Code (ECBC) in India, climate responsive designs and passive cooling techniques are being explored increasingly in building designs. Of all the building envelope components, roof surface has been identified as the most significant with respect to the heat gain due to the incident solar radiation on buildings, especially in tropical climatic conditions. Since ECBC specifies stringent U-Values for roof assembly, use of insulating materials is becoming popular. Along with insulation, the shading of the roof is also observed to be an important strategy for improving thermal performance of the building, especially in Warm and humid climatic conditions. This study intends to assess the impact of roof shading on building’s energy performance in comparison to that of exposed roof with insulation. A typical office building with specific geometry and schedules has been identified as base case model for this study. This building is simulated using energy modelling software ‘Design Builder’ with base case parameters as prescribed in ECBC. Further, the same building has been simulated parametrically adjusting the amount of roof insulation and roof shading simultaneously. The overall energy consumption and the envelope performance of the top floor are extracted for analysis. The results indicate that the roof shading is an effective passive cooling strategy for both naturally ventilated and air conditioned buildings in Warm and humid climates of India. It is also observed that a fully shaded roof outperforms the insulated roof as per ECBC prescription. Provision of shading over roof reduces the annual energy consumption of building in case of both insulated and uninsulated roofs. However, the impact is higher for uninsulated roofs (U-Value of 3.933 W/m2K), being 4.18% as compared to 0.59% for insulated roofs (U-Value of 0.33 W/m2K).While the general assumption is that roof insulation helps in reducing the energy consumption in tropical buildings, it is observed to be the other way when insulation is provided with roof shading. It is due to restricted heat loss during night.


Sign in / Sign up

Export Citation Format

Share Document