Probability Evaluation Method for Cable Safety of Long Span Suspension Bridges under Extreme Wind Load

2010 ◽  
Vol 163-167 ◽  
pp. 3223-3229 ◽  
Author(s):  
Jun Hu ◽  
Jin Ping Ou

The cable is the main load-bearing component of suspension bridge and its safety assessment under extreme wind load is a key issue to the structure. Take a long-span suspension bridge in the East Sea China as an example, the standard of extreme wind load for structural safety evaluation is established; the wire’s strength model is established by the type I extreme value distribution; cable’s safety assessment function under wind load is established and the Monte Carlo method is used to get the cable’s reliability and reliable indicators. The bridge’s re-service term is taken for 90 years as an example, the results indicate that the wire’s serial effects can’t be ignored, the cable’s reliable indicator decreases as the number of broken wires increases in approximately the linear attenuation relations, the critical percentage of broken wires is about 10%.

2021 ◽  
Vol 11 (13) ◽  
pp. 5920
Author(s):  
Dagang Wang ◽  
Jihong Ye ◽  
Bo Wang ◽  
Magd Abdel Wahab

The long-span multi-tower suspension bridge is widely used in the construction of river and sea crossing bridges. The load-bearing safety and anti-sliding safety of its main cable are directly related to the structural safety of a suspension bridge. Failure mechanisms of the main cable of a long-span multi-tower suspension bridge are discussed. Meanwhile, the tribo-corrosion-fatigue of main cable, contact, and slip behaviors of the saddle and service safety assessment of the main cable are reviewed. Finally, research trends in service safety assessment of main cable are proposed. It is of great significance to improve the service safety of the main cable and thereby to ensure the structural safety of long-span multi-tower suspension bridges.


2011 ◽  
Vol 66-68 ◽  
pp. 334-339
Author(s):  
Mei Yu ◽  
Hai Li Liao ◽  
Ming Shui Li ◽  
Cun Ming Ma ◽  
Nan Luo ◽  
...  

Long-span suspension bridges, due to their flexibility and lightness, are much prone to the wind loads, aerodynamics performance has become an important aspect of the design of long-span suspension bridges. In this study, the static wind load acting on the suspension bridge during erection has been investigated through wind tunnel test and numerical analysis. The wind tunnel test was performed using a 1:50 scale section model of the bridge, the static wind load acting on the section model was measured with varying attack angles. Numerical method used here was computational fluid dynamics simulation, a two-dimensional model is adopted in the first stage of the analysis, then the SIMPLE algorithm was employed to solve the governing equations. The analytical results were compared with the wind tunnel test data, it was shown from the study that the results of CFD simulation was good agreement with that of the wind tunnel test.


2006 ◽  
Vol 11 (3) ◽  
pp. 293-318 ◽  
Author(s):  
M. Zribi ◽  
N. B. Almutairi ◽  
M. Abdel-Rohman

The flexibility and low damping of the long span suspended cables in suspension bridges makes them prone to vibrations due to wind and moving loads which affect the dynamic responses of the suspended cables and the bridge deck. This paper investigates the control of vibrations of a suspension bridge due to a vertical load moving on the bridge deck with a constant speed. A vertical cable between the bridge deck and the suspended cables is used to install a hydraulic actuator able to generate an active control force on the bridge deck. Two control schemes are proposed to generate the control force needed to reduce the vertical vibrations in the suspended cables and in the bridge deck. The proposed controllers, whose design is based on Lyapunov theory, guarantee the asymptotic stability of the system. The MATLAB software is used to simulate the performance of the controlled system. The simulation results indicate that the proposed controllers work well. In addition, the performance of the system with the proposed controllers is compared to the performance of the system controlled with a velocity feedback controller.


2021 ◽  
Vol 2021 ◽  
pp. 1-10
Author(s):  
Hao Tian ◽  
Jiji Wang ◽  
Sugong Cao ◽  
Yuanli Chen ◽  
Luwei Li

This paper presents a reliability analysis to assess the safety of corroded main cables of a long-span suspension bridge. A multiscale probability model was established for the resistance of the main cables considering the length effect and the Daniels effect. Corrosion effects were considered in the wire scale by relating the test results from accelerated corrosion tests to the corrosion stages and in the cable scale by adopting a corrosion stage distribution of the main cable section in NCHRP Report 534. The load effects of temperature, wind load, and traffic load were obtained by solving a finite element model with inputs from in-service monitoring data. The so-obtained reliability index of the main cables reduces significantly after operation for over 50 years and falls below the design target value due to corrosion effects on the mechanical properties of the steel wire. Multiple measures should be taken to delay the corrosion effects and ensure the safety of the main cables in the design service life.


2020 ◽  
Vol 980 ◽  
pp. 275-281
Author(s):  
Hu Jun

In order to consider the fluctuating wind load induced fatigue problem of long span suspension bridge, fatigue reliability formula is modified by assuming the fatigue life is accord with the weibull distribution. Based on the accurate bridge buffeting analysis of time history, the stress time history of components of a suspension bridge in east sea China is simulated, and then the fatigue damages and reliabilities are calculated. The results indicate that the main cables and hangers have enough fatigue reliability under the fluctuating wind load, the fatigue failure will not occur; the stiffening girder has larger fatigue damage, under 40 / (m.s-1) mean wind speed action, the girder of mid-support section’s average fatigue life is only 3.103 years, so the girder’s damage under strong wind action should be taken seriously.


2020 ◽  
Vol 10 (21) ◽  
pp. 7666
Author(s):  
Ngoc-Son Dang ◽  
Gi-Tae Rho ◽  
Chang-Su Shim

Long-span suspension bridges require accumulated design and construction technologies owing to challenging environmental conditions and complex engineering practices. Building information modeling (BIM) is a technique used to federate essential data on engineering knowledge regarding cable-supported bridges. In this study, a BIM-based master digital model that uses a data-driven design for multiple purposes is proposed. Information requirements and common data environments are defined considering international BIM standards. A digital inventory for a suspension bridge is created using individual algorithm-based models, and an alignment-based algorithm is used to systematize them and generate the entire bridge system. After assembling the geometrical model, metadata and various BIM applications are linked to create the federated master model, from which the mechanical model is derived for further stages. During the construction stage, the advantage of this digital model lies in its capability to perform efficient revisions and updates with respect to varying situations during the erection process. Stability analyses of the bridge system can be performed continuously at each erection step while considering the geometric control simulation. Furthermore, finite element analysis models for any individual structural member can be extracted from the master digital model, which is aimed at estimating the actual behavior of bridge members. In addition, a pilot master digital model was generated and applied to an existing suspension bridge; this model exhibited significant potential in terms of bridge data generation and manipulation.


2018 ◽  
Vol 18 (08) ◽  
pp. 1840009 ◽  
Author(s):  
Hao Wang ◽  
Yifeng Wu ◽  
Ben Sha ◽  
Wenzhi Zheng ◽  
Yuqi Gao

In the design of super-long-span suspension bridges, the floating system is commonly adopted. However, this system may lead to the excessive earthquake-excited longitudinal displacement (LD) at the end of the main girder, which in return could result in pounding damage at expansion joints. In this paper, Taizhou Bridge, the triple-tower suspension bridge with the longest main span in the world, is taken as an example to demonstrate the effectiveness of three different approaches (elastic links, viscous dampers, and their combination) of mitigating the possible excessive LD. The finite element code ABAQUS is used to build the numerical model of the bridge and calculate the dynamic characteristics as well as the seismic responses. Then, 24 cases with different parameters of elastic links and viscous dampers are investigated and it is observed that the mitigation effect of the 24 cases varies significantly with different parameters. To obtain the optimized mitigation effect for seismic responses, including the LD of the girder, the LD and shear force of all towers, in the 24 cases, the modified analytic hierarchy process (AHP) method is introduced to realize the compositive optimal control of the triple-tower suspension bridge. Results show that the 24th case is the optimal one in which the LD of the girder is reduced significantly while the inner force of towers does not get excessive increase.


2014 ◽  
Vol 633-634 ◽  
pp. 1263-1266
Author(s):  
Huang Yu

For modern long-span bridges, both the optimization of aerodynamic shape and the increase of torsional stiffness according to the result of the wind tunnel experiment could avoid the flutter instability.Vortex-inducedvibration with relatively large amplitude happens easily at low wind speeds. In this paper, based on wind tunnel experiment, by studying on the vortex-induced vibration characteristics of a long-span suspension bridge with single cable plane, aerodynamic measures for easing the vortex-induced vibration are given.


Sign in / Sign up

Export Citation Format

Share Document