Study on Cable-Stayed Bridge Flutter Active Control by a Single ADM

2011 ◽  
Vol 383-390 ◽  
pp. 5071-5075
Author(s):  
Su Qi ◽  
Xing Xing Chen ◽  
Qing Xu

Wind-induced vibration of long span bridges mainly as flutter, buffeting and vortex induced vibration. Buffeting and vortex-induced vibration will not cause the devastating destruction of the bridge, while the chatter is the elastic system in the air of self-excited vibration, when the vibration system from the air flow in the absorption of energy and the energy is greater than the energy damping When consumed, they cause divergence of the self-excited aerodynamic flutter vibration. If the critical flutter wind speed is less than in the bridge office potential wind speed, the bridge flutter may occur caused devastating damage. According to modern control theory, a theoretical analysis is conducted on the active control of cable-stayed bridge flutter, it is established that the controlled equation of cable-stayed bridge controlled by a single active mass damper and the motion equation of a single AMD to determine the calculation method of the critical flutter velocity under the controlled status of the cable-stayed bridge. An example shows that a single ADM is a good means to prevent the flutter damage of long-span cable-stayed bridges.

Symmetry ◽  
2021 ◽  
Vol 13 (9) ◽  
pp. 1633
Author(s):  
Yang Ding ◽  
Shuang-Xi Zhou ◽  
Yong-Qi Wei ◽  
Tong-Lin Yang ◽  
Jing-Liang Dong

Wind field (e.g., wind speed and wind direction) has the characteristics of randomness, nonlinearity, and uncertainty, which can be critical and even destructive on a long-span bridge’s hangers, such as vortex shedding, galloping, and flutter. Nowadays, the finite element method is widely used for model calculation, such as in long-span bridges and high-rise buildings. In this study, the investigated bridge hanger model was established by COMSOL Multiphysics software, which can calculate fluid dynamics (CFD), solid mechanics, and fluid–solid coupling. Regarding the wind field of bridge hangers, the influence of CFD models, wind speed, and wind direction are investigated. Specifically, the bridge hanger structure has symmetrical characteristics, which can greatly reduce the calculation efficiency. Furthermore, the von Mises stress of bridge hangers is calculated based on fluid–solid coupling.


2020 ◽  
pp. 107754632094615
Author(s):  
Yanguo Sun ◽  
Yongfu Lei ◽  
Ming Li ◽  
Haili Liao ◽  
Mingshui Li

As flutter is a very dangerous wind-induced vibration phenomenon, the mitigation and control of flutter are crucial for the design of long-span bridges. In the present study, via a large number of section model wind tunnel tests, the flutter performance of a superlong-span suspension bridge with a double-deck truss girder was studied, and a series of aerodynamic and structural measures were used to mitigate and control its flutter instability. The results show that soft flutter characterized by a lack of an evident divergent point occurred for the double-deck truss girder. Upper central stabilizers on the upper deck, lower stabilizers below the lower deck, and horizontal flaps installed beside the bottoms of the sidewalks are all effective in suppressing flutter for this kind of truss girder. By combining the structural design with aerodynamic optimizations, a redesigned truss girder with widened upper carriers and sidewalks, and double lower stabilizers combined with the inspection vehicle rails is identified as the optimal flutter mitigation scheme. It was also found that the critical flutter wind speed increases with the torsional damping ratio, indicating that the dampers may be efficient in controlling soft flutter characterized by single-degree-of-freedom torsional vibration. This study aims to provide a useful reference and guidance for the flutter design optimization of long-span bridges with double-deck truss girders.


2015 ◽  
Vol 100 ◽  
pp. 468-478 ◽  
Author(s):  
Bejoy P. Alduse ◽  
Sungmoon Jung ◽  
O. Arda Vanli ◽  
Soon-Duck Kwon

2014 ◽  
Vol 501-504 ◽  
pp. 1174-1177
Author(s):  
Xiao Ming Du ◽  
Nan Li

The stayed cable is the key part of the cable-stayed bridge and the main bearing section. Stay cables are prone to vibration under the loads of the rains winds, earthquakes and transportation for the long-span bridge is very flexible and the damping is small. A long time effect of cable vibration on the structure durability has become a serious problem of cable-stayed bridge in the development and operation. Wind induced vibration of stay cable shape is analyzed, and some common damping measures are expounded in the article and it provides the basis for further study in the future.


Sensors ◽  
2020 ◽  
Vol 20 (6) ◽  
pp. 1744 ◽  
Author(s):  
Weiqi Zheng ◽  
Xingwang Sheng ◽  
Zhihui Zhu ◽  
Tianjing Luo ◽  
Zecheng Liu

In this work, we present a series of hammering tests on full-scale unit-plate ballastless tracks used for long-span bridges. There is no denying that it is a new attempt to pave ballastless tracks on high-speed railway long-span bridges; the related issues deserve to be studied, and especially the vibration characteristics. Hence, the vibration characteristics and transmission rules of the ballastless track with geotextile or rubber isolation layers are explored, and the vibration reduction effect of the rubber isolation layer is analyzed. The main conclusions are as follows: the isolation layers change vibration modes and transmission characteristics of ballastless tracks; the introduction of the rubber isolation layer makes the excited vibration frequency range of the ballastless track concentrated; and the vibrations of the ballastless track with the rubber isolation layers are stable. Moreover, the rubber isolation layer has an obvious attenuation effect on vibration transmission in ballastless track structures. When the vibration is transmitted from the rail to the bridge deck, the vibration level differences of the ballastless track with rubber isolation layers are 20 dB larger than that of the ballastless track with the geotextile isolation layers. The vibration attenuation rate of the rubber isolation layer is about ten times larger than that of geotextile isolation layer.


Author(s):  
Jiunn-Yin Tsay

To meet the need of constructing fixed cross strait links, super-long span bridge with a main span over 2 000[Formula: see text]m is considered as a candidate for their ability to cross deep and wide straits. To this end, some super-long span bridges with proper cable and girder systems were previously proposed and studied. The major design considerations are aimed at adopting new cable material, increasing the entire rigidity of the bridge, stabilizing the dynamic characteristics, strengthening the deck sections, etc. In this paper, a brief review of main cable and girder system is first given of the concepts previously proposed for the design of super-long span bridges. Then some typical examples are studied, focused on various issues related to the design of super-long span bridges, including composite cable, the unstressed length and tension force of the main cable, the stiffness and mass effects of the deck on critical wind speed, and the critical wind speed of various cable systems. The most challenges in super-long span bridges are to solve aerostatic and aerodynamic instability at required design wind speed. In this connection, the wind-induced aerostatic instability of super-long span bridges is studied by a two-stage geometric nonlinear analysis for dead loads and wind loads. The developed program adopted herein for geometric nonlinear analysis was verified and confirmed before. The proposed methods (i.e. composite cable, slotted girder, increasing deck stiffness and mass, cable layout, etc.) obtained for all the examples are in agreement with this study, which indicates applicability of the design approaches presented.


Sign in / Sign up

Export Citation Format

Share Document