Axial Compressive Experimental Study on Full-Scale Square Concrete Columns Confined by High-Strength Spiral Hoops

2012 ◽  
Vol 476-478 ◽  
pp. 2036-2041
Author(s):  
Zhen Bao Li ◽  
Wen Jing Wang ◽  
Wei Jing Zhang ◽  
Yun Da Shao ◽  
Bing Zhang ◽  
...  

3 specimens of full-scale reinforced concrete columns were tested under monotonic axial loading, in which the hoop configuration of one specimen was #, and the other two used the two-directional composite spiral hoops. The axial compressive performances of full-scale reinforced concrete columns confined by different configurations and strengths of hoops were discussed. One of the columns confined by spiral hoops used high-strength steels with the yield strength of 1000MPa as hoops, while the other two columns used ordinary-strength steel with yield strength of 400MPa. Columns confined by spiral hoops exhibited slight higher bearing capacity and better deformation ability than columns with hoop configuration #. The results also indicated that compared with the specimen used ordinary-strength hoops, the bearing capacity of the specimen used high-strength hoops was basically the same, but the deformation ability improved obviously.

2012 ◽  
Vol 446-449 ◽  
pp. 981-988
Author(s):  
Zhen Bao Li ◽  
Wen Jing Wang ◽  
Wei Jing Zhang ◽  
Yun Da Shao ◽  
Bing Zhang ◽  
...  

Axial compression experiments of four full-scale reinforced concrete columns of two groups were carried out. One group of three columns used high-strength steel with the yield strength of 1000MPa as reinforcement hoops, and the second group used the ordinary-strength steel with yield strength of 400MPa. The axial compressive performances between these two groups were assessed. Compared to the specimen using the ordinary-strength steel, the axial compressive bearing capacity of using the high strength steel dose not increase significantly, while the deformation ability increases greatly. The results also indicate that the stress redistributions of the hoops and the concrete sections are obvious, and long-lasting when specimens achieve the ultimate bearing capacity after the yield of the rebar and local damage of concrete materials, at this time the strain of the specimens developes a lot, especially stress - strain curves of speciments with high-strength hoop all show a wide and flat top.


2012 ◽  
Vol 166-169 ◽  
pp. 836-842
Author(s):  
Wei Jing Zhang ◽  
Bing Zhang ◽  
Zhen Bao Li ◽  
Jinjin Wang ◽  
Wen Jing Wang

To investigate the axial compressive behavior of reinforced concrete columns with strong confinement, a total of five full-scale reinforced concrete columns with stirrup characteristic values in the range 0.22~0.47 and section dimension 600mm×600mm were tested under concentric compression loading. The test results indicated that all specimens failed in a similar way. The longitudinal bars buckled in compression; the peripheral stirrups bowed out and several stirrups fractured; the cover concrete in the mid-height section of specimens spalled seriously; however, the core concrete of specimens was not crushed. The axial compressive bearing capacity and deformation ability of reinforced concrete columns could be improved by strong confinement. When specimens reached the ultimate bearing capacity, the longitudinal reinforcement yielded and provided axial bearing capacity for specimens; the transverse reinforcement reached tensile yield strength and provided effective confinement for the core concrete.


Author(s):  
А. Аль-Хаваф ◽  
A. Al'-Havaf ◽  
А. Никулин ◽  
Aleksandr Nikulin

The article presents results of experimental studies of centrally compressed reinforced concrete columns with the addition of concrete rubble as coarse aggregate. Previous studies shows that recycled concrete in the form of crushed concrete rubble obtained from construction waste is an environmentally friendly alternative to traditional coarse aggregate for the manufacture of load-bearing structures. Currently, the scientific literature has a limited amount of information about the calculation methods to be used for the design of reinforced concrete columns with the addition of concrete rubble as coarse aggregate. In this paper, the experimental data on the physicomechanical properties of concrete available in the foreign and domestic literature are summarized. In addition, the deformation features of reinforced concrete columns are highlighted to substantiate the initial premises, hypotheses and possible limitations when developing methods for calculating centrally and eccentrically compressed elements from the specified concrete. Researches are analyzed related to the effect of different content of recycled concrete aggregate in the concrete, the number of longitudinal steel reinforcement in the cross section of the element and its yield strength, pitch and yield strength of transverse reinforcement on the deformability and bearing capacity of concrete columns with the addition of coarse aggregate from concrete rubble. The use of such concrete for the manufacture of centrally and eccentrically compressed concrete columns leads to an insignificant decrease in their bearing capacity. This indicates the possibility of recycling a significant amount of concrete rubble resulting from the processing of reinforced concrete structures destroyed during the demolition of buildings; it allows to attribute this technology to “green building”.


Author(s):  
Л. Р. Маилян ◽  
С. А. Стельмах ◽  
Е. М. Щербань ◽  
М. П. Нажуев

Состояние проблемы. Железобетонные элементы изготавливаются, как правило, по трем основным технологиям - вибрированием, центрифугированием и виброцентрифугированием. Однако все основные расчетные зависимости для определения их несущей способности выведены, исходя из основного постулата - постоянства и равенства характеристик бетона по сечению, что реализуется лишь в вибрированных колоннах. Результаты. В рамках диаграммного подхода предложены итерационный, приближенный и упрощенный способы расчета несущей способности железобетонных вибрированных, центрифугированных и виброцентрифугированных колонн. Выводы. Расчет по диаграммному подходу показал существенно более подходящую сходимость с опытными данными, чем расчет по методике норм, а также дал лучшие результаты при использовании дифференциальных характеристик бетона, чем при использовании интегральных и, тем более, нормативных характеристик бетона. Statement of the problem. Reinforced concrete elements are typically manufactured according to three basic technologies - vibration, centrifugation and vibrocentrifugation. However, all the basic calculated dependencies for determining their bearing capacity were derived using the main postulate, i.e., the constancy and equality of the characteristics of concrete over the cross section, which is implemented only in vibrated columns. Results. Within the framework of the diagrammatic approach, iterative, approximate and simplified methods of calculating the bearing capacity of reinforced concrete vibrated, centrifuged and vibrocentrifuged columns are proposed. Conclusions. The calculation according to the diagrammatic approach showed a significantly better convergence with the experimental data than that using the method of norms, and also performs better when using differential characteristics of concrete than when employing integral and particularly standard characteristics of concrete.


2012 ◽  
Vol 5 (3) ◽  
pp. 305-315
Author(s):  
P. P. Nascimento ◽  
R. B. Gomes ◽  
L. L. J. Borges ◽  
D. L. David

There are many problems involving cases of destruction of buildings and other structures. The columns can deteriorate for several reasons such as the evolution and changing habits of the loads. The experimental phase of this work was based on a test involving nine reinforced concrete columns under combined bending and axial compression, at an initial eccentricity of 60 mm. Two columns were used as reference, one having the original dimensions of the column and the other, monolithic, had been cast along the thickness of the strengthened piece. The remaining columns received a 35 mm thick layer of self-compacting concrete on their compressed face. For the preparation of the interface between the two materials, this surface was scarified and furrowed and connectors were inserted onto the columns' shear reinforcement in various positions and amounts.As connectors, 5 mm diameter steel bars were used (the same as for stirrups), bent in the shape of a "C" with 25 mm coatings. >As a conclusion, not only the quantity, but mainly, the location of the connectors used in the link between substrate and reinforcement is crucial to increase strength and to change failure mode.


Author(s):  
Yonghui Hou ◽  
Shuangyin Cao ◽  
Xiangyong Ni ◽  
Yizhu Li

The use of new developed high-strength steel in concrete members can reduce steel bars congestion and construction costs. This research aims to study the behavior of concrete columns reinforced with new developed high-strength steel under eccentric loading. Ten reinforced concrete columns were fabricated and tested. The test variables are transverse reinforcement amount and yield strength, eccentricity, and longitudinal reinforcement yield strength. The failure patterns are compression and tensile failure for columns subjected to small eccentricity and large eccentricity, respectively. The same level of post-peak deformability and ductility only can be obtained with lower amount of transverse reinforcement when high-strength transverse reinforcements are used in columns subjected to small eccentricity. The high-strength longitudinal reinforcement can improve bearing capacity and post-peak deformability of concrete columns. Besides, three different equivalent rectangular stress block (ERSB) parameters in predicting bearing capacity of columns with high-strength steel were discussed based on test and simulated results. It is concluded that the Code of GB 50010-2010 overestimates the bearing capacity of columns with high-strength steel, whereas bearing capacities computed using Codes of ACI 318-14 and CSA A23.3-04 agree well with test results.


2016 ◽  
Vol 9 (1) ◽  
pp. 1-21 ◽  
Author(s):  
D. B. FERREIRA ◽  
R. B. GOMES ◽  
A. L. CARVALHO ◽  
G. N. GUIMARÃES

This article presents the study of reinforced concrete columns strengthened using a partial jacket consisting of a 35mm self-compacting concrete layer added to its most compressed face and tested in combined compression and uniaxial bending until rupture. Wedge bolt connectors were used to increase bond at the interface between the two concrete layers of different ages. Seven 2000 mm long columns were tested. Two columns were cast monolithically and named PO (original column) e PR (reference column). The other five columns were strengthened using a new 35 mm thick self-compacting concrete layer attached to the column face subjected to highest compressive stresses. Column PO had a 120mm by 250 mm rectangular cross section and other columns had a 155 mm by 250mm cross section after the strengthening procedure. Results show that the ultimate resistance of the strengthened columns was more than three times the ultimate resistance of the original column PO, indicating the effectiveness of the strengthening procedure. Detachment of the new concrete layer with concrete crushing and steel yielding occurred in the strengthened columns.


2018 ◽  
Vol 2018 ◽  
pp. 1-19
Author(s):  
Chunyi Yu ◽  
Hua Ma ◽  
Yongping Xie ◽  
Zhenbao Li ◽  
Zhenyun Tang

The size effect on the seismic performance of conventional reinforced concrete columns has been observed in terms of flexural failure and shear failure. Under earthquake loading, slender columns experience flexural failure, and short columns experience flexure-shear failure and shear failure. However, the effect of section size on the seismic performance of high-strength reinforced concrete columns under the conditions of different shear span-to-depth ratios requires further confirmation. For this purpose, six high-strength reinforced concrete columns with shear span-to-depth ratios of 2 and 4 were subjected to cyclic loading in this study. The experimental results indicated that relative nominal flexural strength, energy dissipation coefficient, factor of safety, and local factor of safety all exhibited a strong size effect by decreasing with increasing column size. Furthermore, the size effect became stronger as the shear span-to-depth ratio was increased, except for average energy dissipation coefficient. The observed changes in the factor of safety were in good agreement with the Type 2 size effect model proposed by Bažant. Thus, based on the local factor of safety and Bažant’s Type 2 model, the code equation for moment capacity of different shear span-to-depth ratios was modified to provide a consistent factor of safety regardless of column size.