Impact Factors Study on Strength of Steel Tube Confined Concrete Columns under Axial Compression

2013 ◽  
Vol 639-640 ◽  
pp. 1069-1072
Author(s):  
Hao Xiong Feng ◽  
Wei Jian Yi

This paper describes principle and working mechanism of the steel tube confined concrete, to analyze impact factors of steel tube confined concrete strength. By the studies, presents several solutions to improve the strength of steel tube confined concrete, fully execute the behavior of steel tube and filled-in-concrete, strengthen the interactions between steel tube and filled-in-concrete to provide theoretical basis for the design and use of steel tube confined concrete.

Author(s):  
Xindong Ding ◽  
Shuqing Wang ◽  
Yu Liu ◽  
Zepeng Zheng

Axial compression tests were carried out on 6 square steel tube confined concrete short columns and 6 BFRP square pipe confined concrete axial compression tests. The concrete strength grades were C30, C40, and C50. The test results show that the failure modes of steel pipe and BFRP pipe are obviously different, and the BFRP pipe undergoes brittle failure. Compared with the short columns of concrete confined by BFRP pipes, the ultimate bearing capacity of axial compression is increased by -76.46%, -76.01%, and -73.06%, and the ultimate displacements are -79.20%, -80.78%, -71.71%.


Author(s):  
Xindong DING ◽  
Shuqing Wang ◽  
Yu Liu ◽  
Zepeng Zheng

Axial compression tests were carried out on 6 square steel tube confined concrete short columns and 6 BFRP square pipe confined concrete axial compression tests. The concrete strength grades were C30, C40, and C50. The test results show that the failure modes of steel pipe and BFRP pipe are obviously different, and the BFRP pipe undergoes brittle failure. Compared with the short columns of concrete confined by BFRP pipes, the ultimate bearing capacity of axial compression is increased by -76.46%, -76.01%, and -73.06%, and the ultimate displacements are -79.20%, -80.78%, -71.71%.


2010 ◽  
Vol 168-170 ◽  
pp. 2154-2157
Author(s):  
Jing Yu Chen ◽  
Ying Hai

The use of steel tube confined concrete columns has been the interests of many structural engineers. For investigation of the axially loading capacity of short concrete filled double skin tubes (CFDST) columns, axial compression loading experiments were carried on 9 short CFDST column samples. According to experimental results and with numerical analysis, an ultimate load estimation equation of CFDST column with one correction parameter is presented, the linear relation between the parameter and the inner-to-outer diameters ratio Di/Do is given out. The ultimate load estimation equation is validated by the test results of short CFDST column samples.


2021 ◽  
Vol 2021 ◽  
pp. 1-13
Author(s):  
Yuchuan Wen ◽  
Zhongjun Hu ◽  
Anningjing Li ◽  
Quanheng Li ◽  
Xuepeng Li ◽  
...  

This study investigates the suitability of the circularization technique for strengthening square concrete-filled square steel tube (CFSST) short columns. A total of 16 specimens were tested under axial compression. The main parameters under investigation were concrete strength, the thickness of arc cement mortar layer components (CAM), and the layers of carbon fiber-reinforced polymer (CFRP) sheets. Test results indicated that the failure mode of CFRP-confined circularized CFSST (C-C-CFSST) columns was similar to that of CFRP-confined concrete columns. The CFRP-confined circularized strengthening method can increase confinement efficacy and reduce the stress concentration at the corners of CFSST columns. Three existing CFRP-confined concrete stress-strain models were evaluated using the test results. The predictions of the Lam and Teng stress-strain model agree well with the test data.


2020 ◽  
pp. 136943322098165
Author(s):  
J.G. Teng ◽  
J.J. Wang ◽  
Guan Lin ◽  
J. Zhang ◽  
P. Feng

Concrete-filled steel tubular (CFST) columns have been extensively studied and widely used in practice. Existing research has shown that non-circular CFST columns is much less ductile than their circular counterparts, particularly when thin/high strength steel (HSS) tubes and high-strength concrete are used. To address this problem, a new form of CFST columns has recently been proposed by the first author. The new column consists of a steel tube filled with concrete that is confined with HSS spiral reinforcement typically with a yield stress exceeding 1000 MPa. These columns, referred to as confined concrete-filled steel tubular (CCFST) columns, also maintain the ease for connection to CFST or steel beams. This paper presents the results of a series of concentric axial compression tests on such columns of square cross-section to demonstrate their advantages. The experimental program included 13 CCFST columns, four CFST columns without internal spiral confinement, two hollow steel tube (HST) columns, and 11 circular HSS spiral-confined concrete columns. Three different compressive strengths and three HSS spiral pitches were examined in the experimental program. The CFST columns, HST columns, and HSS spiral-confined concrete columns were all tested under axial compression to gain a good understanding of the confinement mechanism in a CCFST column. The test results show that the new columns possess much greater ductility than those without internal spiral confinement, although the use of HSS spirals increases the steel volume by only a small percentage. It is also shown that the axial load-axial strain curve of a CCFST column can be conservatively predicted by summing the axial load-axial strain curves of the hollow steel tube without local buckling, the HSS spiral-confined concrete core, and the sandwiched concrete between the two.


2019 ◽  
Vol 11 (1) ◽  
pp. 82-106 ◽  
Author(s):  
Mahfoud Touhari ◽  
Ratiba Kettab Mitiche

Purpose Covering a fiber-reinforced concrete column (fiber reinforced plastic (FRP)) improves the performance of the column primarily. The purpose of this paper is to investigate the behavior of small FRP concrete columns that are subject to axial pressure loading, in order to study the effect of many parameters on the effectiveness of FRP couplings on circular and square concrete columns. Design/methodology/approach These parameters include the shape of the browser (circular and square), whole core and cavity, square radius of square columns, concrete strength (low strength, normal and high), type of FRP (carbon and glass) and number of FRP (1–3) layers. The effective fibrillation failure strain was investigated and the effect of effective lateral occlusion pressure. Findings The results of the test showed that the FRP-coated columns improved significantly the final conditions of both the circular and square samples compared to the unrestricted columns; however, improvement of square samples was not as prominent as improvement in circular samples. The results indicated that many parameters significantly affected the behavior of FRP-confined columns. A new model for predicting compressive force and the corresponding strain of FRP is presented. A good relationship is obtained between the proposed equations and the current experimental results. Originality/value The average hoop strain in FRP wraps at rupture in FRP-confined concrete specimens can be much lower than that given by tensile coupon tests, meaning the theoretical assumption that the FRP-confined concrete cylinder ruptures when the FRP material tensile strength attained at its maximum is not suitable. Based on this observation, the effective peak strength and corresponding strain formula for FRP concrete confined columns must be based on the effective hoop rupture strain composite materials.


2011 ◽  
Vol 94-96 ◽  
pp. 1983-1988
Author(s):  
Jia Song ◽  
Zhen Bao Li ◽  
Yong Ping Xie ◽  
Xiu Li Du ◽  
Yue Gao

An experimental study was made of the mechanical properties of large scale confined concrete subjected to the axial compression test. Eleven tied concrete columns and six plain concrete prisms were tested. In the test, each specimen had the same transverse reinforcement configuration, and similar volumetric ratio of lateral steel, while different size. The test results in this paper indicate that the size of the specimen has no obvious relationship with the ultimate strength, however, it does affect the post-peak ductility to some extent. As a supplement to the experimental study, a finite element method was adopted to imitate the mechanical behavior of the confined concrete under axial compression. The results of the imitation in this paper indicate the confinement mechanism of large scale specimens.