Comparison of the Application of 3G and COFDM in UHV Transmission Lines Inspection

2013 ◽  
Vol 756-759 ◽  
pp. 477-481
Author(s):  
Jue Li ◽  
Yao Lu ◽  
Bing Qi ◽  
Xiang Jun Liu

With the rapid construction of UHV power grid in China, the difficulty of transmission lines inspection and maintenance has increased dramatically. Thus it is urgent to adopt new technologies to replace the traditional manual mode of transmission lines inspection and maintenance. In this paper, the characteristics and applications in UHV transmission lines inspection of 3G and COFDM technology are analyzed and compared.

Author(s):  
Nina B. Rubtsova ◽  
Sergey Yu. Perov ◽  
Olga V. Belaya ◽  
Tatiana A. Konshina

Introduction. Electromagnetic safety of power grid facilities staff requires the exclusion of electromagnetic fields (EMF) harmful effects. EMF is evaluated by 50 Hz electric and magnetic fields (EF and MF) values in the framework of working conditions special assessment, and very rarely the analysis of the electromagnetic environment (EME) is carried out in depth. The aim of the study - EME hygienic assessment of power grid EHV facilities personnel workplace with adequate 50 Hz EF and MF levels evaluation as well as the analysis of EF and MF in the frequency range from 5 Hz to 500 Hz amplitude-frequency characteristics. Materials and methods. 50 Hz EF and MF values assessment was carried out on open switchgears (S) of substations and within sanitary breaks of 500 and 750 kV overhead power transmission lines (OTL). Measurements along to OTL trasses was performed using matrix-based method. Measurements and analysis of EF and MF values in 5-500 Hz frequency range amplitude-frequency characteristics were performed in the territory of 500 and 750 kV S. Results. Power frequency 50 Hz measurements results at 500 and 750 kV S ground-level personnel workplaces showed the presence of an excess of permissible limit values by EF intensity and the absence of an excess by MF. The measured EF values within 500 and 750 kV OTL sanitary gaps require limiting the working time of linemen due to the excess of the hygienic norms for full work shift, while the MP levels were almost completely within the standard values for persons not occupationally connected with electrical installations maintenance. MF and EE frequency range from 50 Hz to 500 Hz spectral characteristics analysis showed that 3rd harmonic percentage does not exceed 2.5% for EF and 6% for MF of the main level, the level of the 5th harmonic does not exceed 1% for EF and 3.5% for MF, the level of the 7th harmonic does not exceed 0.2% for EF and 0.8% for MF. These data show despite its low levels the contribution of MF different harmonics in a possible adverse impact on humane than EF corresponding harmonics. Conclusions. There was the confirmation of the previously justified use of the "matrix" scheme for of EF and MF values measurement along OTL routes. The relevance of to EF and MF all frequency components expos ure assessing possible health risk in extremely high voltage S territories and under OTL, based on international recommendations due to the lack of sanitary regulations in the Russian Federation for >50 Hz-30 kHz EF and MF, is shown.


2022 ◽  
pp. 1192-1211
Author(s):  
Cosmin Darab

Electric vehicles were proposed as a good solution to solving energy crisis and environmental problems caused by the traditional internal combustion engine vehicles. In the last years due to the rapid development of the electric vehicles, the problem of power grid integration was addressed. In order to not put additional pressure onto the power grid several new technologies were developed. This chapter presents the smart grid technology, vehicle-to-grid concept, and electric vehicles grid integration. These technologies made possible the integration of electric vehicles without any major changes in the power grid. Moreover, electric vehicles integration brought new benefits to the power grid like better integration of renewable energy.


2022 ◽  
pp. 506-528
Author(s):  
Sa'ed Abed ◽  
Areej Abdelaal ◽  
Amjad Gawanmeh

Energy demand has increased significantly in the recent years due to the emerging of new technologies and industries, in particular in the developing countries. This increase requires much more developed power grid system than the existing traditional ones. Smart grid (SG) offers a potential solution to this problem. Being one of the most needed and complex cyber-physical systems (CPS), SG has been addressed exhaustively by researchers, from different views and aspects. However, energy optimization yet needs much more studying and examination. Therefore, this chapter presents a comprehensive investigation and analysis of the state-of-the-art developments in SG as a CPS with emphasis on energy optimization techniques and challenges. It also surveys the main challenges facing the SG considering CPS factors and the remarkable accomplishments and techniques in addressing these challenges. In addition, the document contrasts between different techniques according to their efficiency, usage, and feasibility. Moreover, this work explores the most effective applications of the SG as a CPS.