scholarly journals Experimental Study on The Effect of Capillary Tube Geometry on The Performance of Vapour Compression Refrigeration System

2014 ◽  
Vol 7 (2) ◽  
pp. 47-60
Author(s):  
Abdul- Kareem R. Abed ◽  
Hassan Jawdat Fadhiel ◽  
Gaydaa Mahsun ◽  
Thabet C. Yassen

A domestic refrigerator of 5 ft3 capacity is used to study the effect of coiled diameter and pitch distance of a capillary tube. Five capillary tubes of 2 mm in diameter and 1500 mm length each are used, as same as original capillary tube of the refrigerator. The capillary tubes is formed in five shapes, each one has different coil diameter (D) namely 25, 50, 75, 100 and 125 mm in diameter, in addition three distances between each coil (pitch (P)) is tested, namely 6, 8 and 10 mm. The pressure at inlet and outlet of capillary are measured to calculate the cycle COP, as well as the power consumed by the cycle compressor is measured to calculate the mass flow rate of refrigerant. The work show that the coiled diameter of capillary tube affect the cycle COP strongly, as the capillary coiled diameter (D) increases from 25 to 100 mm the cycle COP increases from 2.8 to 3.7 when the cabinet temperature equals to 8oC. The increases of coiled diameter more than 100 mm shows insignificant effect on the cycle COP. While the pitch space of capillary tube coiled shows minor effect on the cycle COP. Moreover, to the mass flow rate of refrigerant increases with approximately ranges from 1.2−2.7

2014 ◽  
Vol 960-961 ◽  
pp. 643-647
Author(s):  
Yan Sheng Xu

A stepped capillary tube consisting of two serially connected capillary tubes with different diameters is invented to replace the conventional expansion device. The mass flow rate of refrigerant R410A in stepped capillary tubes with different size were tested. The model of stepped capillary tube is proposed, and its numerical algorithm for tube length and mass flow rate is developed. The experimental results show that the performance comparing between stepped capillary tube system and capillary tube assembly system, the cooling capacity is reduced by 0.3%, the energy efficiency ratio (EER) is equal to each other, the heating capacity is increased by 0.3%, the coefficient of performance (COP) is decreased by 0.3%. That is to say, the performance index of the two kinds of throttle mechanism is almost identical. It indicates that the stepped capillary tube can replace the capillary tube assembly in the R410A heat pump type air conditioner absolutely. The model is validated with experimental data, and the results show that the model can be used for sizing and rating stepped capillary tube.


Author(s):  
Badrish Pandey ◽  
Desireddy Shashidhar Reddy ◽  
Mohd. Kaleem Khan ◽  
Manabendra Pathak

The present research work is undertaken to develop ASHRAE like standard rating charts for currently used refrigerants R-134a and R-410A and their potential low global warming potential (GWP) substitutes R-1234yf and R-32, respectively. A self-adjustable mass prediction algorithm has been developed using an averaging technique. Based on this, a matlab code dynamically linked to refprop v. 9.0 software has been developed that solves governing equations of mass, momentum, and energy. Two-phase flow inside the capillary tube is assumed homogeneous and metastability is ignored in the proposed model. The proposed numerical models are in good agreement with the available experimental data with overall percentage mean deviation is less than 6%. Coil diameter plays an important role in adjusting the mass flow rate in the helical capillary tube. Coiling of capillary tube causes an increase in friction pressure drop and a reduction in refrigerant mass flow rate. It has been found that the mass flow rate reduces by about 5% as coil diameter is reduced from 120 to 20 mm.


2017 ◽  
Vol 25 (04) ◽  
pp. 1730004 ◽  
Author(s):  
Mehdi Rasti ◽  
Ji Hwan Jeong

Capillary tubes are widely used as expansion devices in small-capacity refrigeration systems. Since the refrigerant flow through the capillary tubes is complex, many researchers presented empirical dimensionless correlations to predict the refrigerant mass flow rate. A comprehensive review of the dimensionless correlations for the prediction of refrigerants mass flow rate through straight and coiled capillary tubes depending on their geometry and adiabatic or diabatic capillary tubes depending on the flow configurations has been discussed. A comprehensive review shows that most of previous dimensionless correlations have problems such as discontinuity at the saturated lines or ability to predict the refrigerant mass flow rate only for the capillary tube subcooled inlet condition. The correlations suggested by Rasti et al. and Rasti and Jeong appeared to be general and continuous and these correlations can be used to predict the refrigerant mass flow rate through all the types of capillary tubes with wide range of capillary tube inlet conditions including subcooled liquid, two-phase mixture, and superheated vapor conditions.


1996 ◽  
Vol 118 (1) ◽  
pp. 150-154 ◽  
Author(s):  
Tuncay Yilmaz ◽  
Saban U¨nal

Capillary tubes are used widely in small refrigeration systems. It is necessary to design the capillary tube, but there does not exist any analytical equation which allows the determination of capillary tube length or mass flow rate for all refrigerants. In this work, an analytical equation is derived which allows to design the capillary tubes. The comparison with existing methods and experimentally obtained values using the refrigerants R12, R22, R113, R114, R134a, and R600a has turned out to be satisfactory.


2014 ◽  
Vol 22 (04) ◽  
pp. 1450022 ◽  
Author(s):  
CHI ZHANG ◽  
YING WANG ◽  
JIANGPING CHEN

Mal-distribution of refrigerant in a cross-flow type evaporator with parallel paths is very important, which can lead to a loss of heat exchanger capacity to 25%. Distributors are used to balance the two-phase refrigerant distributions in each path. Apart from the structural factors, there are other factors influencing the performance of distributor greatly. In this paper, influences of several nonstructural factors on reservoir distributor are investigated experimentally under varied working conditions. The inlet tube configuration, installation orientation and capillary tube length are also studied. One experiment apparatus is developed to measure the refrigerant mass flow rate and the quality based on R410A air conditioner. It is found that influence caused by inlet tube before the distributor is small. The average STD is only 2.76%. Influence caused by orientation is broad. The average STD is less than 9% on the orientation of 15°. On the orientation of 90°, STDs of different conditions are all more than 40%. For orientation, mass flow rate sensitivity is larger than quality sensitivity. Capillary tubes with different length can be used to adjust distribution. Average STD with sizable capillary length difference is 9.47%. It means that only small mal-distribution can be adjusted by using different-length capillary tubes. Capillary tube length sensitivity increases with the increase of difference between outlet tubes or the decrease of average length of outlet tubes.


Author(s):  
M. K. Mittal ◽  
R. Kumar ◽  
A. Gupta

The objective of this study is to investigate the effect of coiling on the flow characteristics of R-407C in an adiabatic spiral capillary tube. The characteristic coiling parameter for a spiral capillary tube is the coil pitch; hence, the effect of the coil pitch on the mass flow rate of R-407C was studied on several capillary tube test sections. It was observed that the coiling of the capillary tube significantly reduced the mass flow rate of R-407C in the adiabatic spiral capillary tube. In order to quantify the effect of coiling, the experiments were also conducted for straight a capillary tube, and it was observed that the coiling of the capillary tube reduced the mass flow rate in the spiral tube in the range of 9–18% as compared with that in the straight capillary tube. A generalized nondimensional correlation for the prediction of the mass flow rates of various refrigerants was developed for the straight capillary tube on the basis of the experimental data of R-407C of the present study, and the data of R-134a, R-22, and R-410A measured by other researchers. Additionally, a refrigerant-specific correlation for the spiral capillary was also proposed on the basis of the experimental data of R-407C of the present study.


2020 ◽  
Vol 118 ◽  
pp. 269-278 ◽  
Author(s):  
Thiago Torres Martins Rocha ◽  
Cleison Henrique de Paula ◽  
Vinícius Melo Cangussu ◽  
Antônio Augusto Torres Maia ◽  
Raphael Nunes de Oliveira

2015 ◽  
Vol 23 (02) ◽  
pp. 1550015 ◽  
Author(s):  
Ahmad Sharifian ◽  
Jeri Tangalajuk Siang

The performance of a portable propane air conditioner system, in which the temperatures of the air passing over the condenser and evaporator are equal, has been experimentally investigated under different room temperatures and refrigerant charge levels. The research has been carried out in a range of room temperatures from 20°C to 35°C and in undercharge, standard charge and overcharge conditions. The results show that, at higher room temperatures, the refrigerant temperature in all parts of the system, the density of the refrigerant at the inlet and outlet of the condenser, mass of the refrigerant in the compressor, the mass flow rate of the refrigerant and the cooling capacity of the system in either the undercharge or full charge condition, the specific cooling capacity of the undercharge system, the useful work of the compressor, and the maximum pressure of the refrigerant increase. The increase in room temperature decreases the density of the refrigerant at the inlet and outlet of the capillary tube, the mass of the refrigerant in the capillary tube, the refrigerant subcooling at the inlet of the capillary tube, the maximum velocity of the refrigerant and the coefficient of performance. In addition, the increase in room temperature at overcharge condition causes an increase in the mass flow rate, cooling capacity and specific cooling capacity to a maximum value followed by their decrease. The most important difference between a portable air conditioner and a nonportable system is the increase in cooling capacity with an increase in room temperature in full charge condition.