Research on the Application of 20 Degrees Probe Pair in TOFD

2014 ◽  
Vol 998-999 ◽  
pp. 957-961
Author(s):  
Xiao Jun Hao ◽  
Ji Feng Zhao ◽  
Xiao Guang Niu ◽  
Chang Fu Liu ◽  
Wen Bin Li ◽  
...  

The feasibility of the application of probes with refraction angle of 20 degrees is discussed, and application effects of the probe are verified by experimental testing. The result shows, for ultrasonic TOFD testing of small flaws in lower part of high-wall-thickness work-pieces, the probe pair with refraction angle of 20 degree is superior to 45 degrees.

Author(s):  
Grzegorz Samołyk ◽  
Grzegorz Winiarski

AbstractThis paper presents the results of a study investigating a cold forging process for producing hollow balls with different wall thicknesses. The study was performed by FEM numerical modelling, which made it possible to obtain a wide spectrum of results. For the analysis of FEM results obtained for problematic cases (shape defects in forged balls), novel hypotheses for results interpretation are proposed. The FEM numerical model and hypotheses are then verified via experimental testing, and selected theoretical results are compared with experimental findings. Finally, obtained results are discussed (e.g. the effect of billet dimensions on forging conditions, wall thickness and hole size), a method for FEM results interpretation is presented, and design-related solutions ensuring the production of defect-free hollow balls are proposed.


1996 ◽  
Vol 35 (05) ◽  
pp. 146-152 ◽  
Author(s):  
A. Kögler ◽  
H.-A. Schmitt ◽  
D. Emrich ◽  
H. Kreuzer ◽  
D. L. Munz ◽  
...  

SummaryThis prospective study assessed myocardial viability in 30 patients with coronary heart disease and persistent defects despite reinjection on TI-201 single-photon computed tomography (SPECT). In each patient, three observers graded TI-201 uptake in 7 left ventricular wall segments. Gradient-echo magnetic resonance imaging in the region of the persistent defect generated 12 to 16 short axis views representing a cardiac cycle. A total of 120 segments were analyzed. Mean end-diastolic wall thickness and systolic wall thickening (± SD) was 11.5 ± 2.7 mm and 5.8 ± 3.9 mm in 48 segments with normal TI-201 uptake, 10.1 ± 3.4 mm and 3.7 ± 3.1 mm in 31 with reversible lesions, 11.3 ± 2.8 mm and 3.3 ± 1.9 mm in 10 with mild persistent defects, 9.2 ± 2.9 mm and 3.2 ±2.2 mm in 15 with moderate persistent defects, 5.8 ± 1.7 mm and 1.3 ± 1.4 mm in 16 with severe persistent defects, respectively. Significant differences in mean end-diastolic wall thickness (p <0.0005) and systolic wall thickening (p <0.005) were found only between segments with severe persistent defects and all other groups, but not among the other groups. On follow-up in 11 patients after revascularization, 6 segments with mild-to-moderate persistent defects showed improvement in mean systolic wall thickening that was not seen in 6 other segments with severe persistent defects. These data indicate that most myocardial segments with mild and moderate persistent TI-201 defects after reinjection still contain viable tissue. Segments with severe persistent defects, however, represent predominantly nonviable myocardium without contractile function.


1995 ◽  
Vol 32 (3) ◽  
pp. 453
Author(s):  
Sung Hoon Chung ◽  
Hyun Sook Kim ◽  
In Oak Ahn ◽  
Goo Lee ◽  
Joon Hee Joh

Author(s):  
Deepak D. ◽  
Nitesh Kumar ◽  
Shreyas P. Shetty ◽  
Saurabh Jain ◽  
Manoj Bhat

The expensive nature of currently used materials in the soft robotic industry demands the consideration of alternative materials for fabrication. This work investigates the performance of RTV-2 grade silicone rubber for fabrication of a soft actuator. Initially, a cylindrical actuator is fabricated using this material and its performance is experimentally assessed for different pressures. Further, parametric variations of the effect of wall thickness and inflation pressure are studied by numerical methods. Results show that, both wall thickness and inflation pressure are influential parameters which affect the elongation behaviour of the actuator. Thin (1.5 mm) sectioned actuators produced 76.97% more elongation compared to thick sectioned, but the stress induced is 89.61 % higher. Whereas, the thick sectioned actuator (6 mm) showed a higher load transmitting capability. With change in wall thickness from 1.5 mm to 6 mm, the elongation is reduced by 76.97 %, 38.35 %, 21.05 % and 11.43 % at pressure 100 kPa, 75 kPa, 50 kPa and 25 kPa respectively. The induced stress is also found reduced by 89.61 %, 86.66 %, 84.46 % and 68.68 % at these pressures. The average load carrying capacity of the actuator is found to be directly proportional to its wall thickness and inflation pressure.


PCI Journal ◽  
2019 ◽  
Vol 64 (1) ◽  
Author(s):  
Cameron D. Murray ◽  
Brittany N. Cranor ◽  
Royce W. Floyd ◽  
Jin-Song Pei

2019 ◽  
Author(s):  
Joppe Rutten ◽  
Jens Verschoren ◽  
Nesrin Ozalp ◽  
Cédric Ophoff ◽  
David Moens

2014 ◽  
Vol 11 (1) ◽  
pp. 51
Author(s):  
Mohd Helmy Ibrahim ◽  
Mohd Nazip Suratman ◽  
Razali Abd Kader

Trees planted from agroforestry practices can become valuable resources in meeting the wood requirements of many nations. Gliricidia sepium is an exotic species introduced to the agricultural sector in Malaysia mainly for providing shade for cocoa and coffee plantations. This study investigates its wood physical properties (specific gravity and moisture content) and fibre morphology (length, lumen diameter and cell wall thickness) of G. sepium at three intervals according to age groups ( three, five and seven years of ages). Specific gravity (0.72) was significantly higher at seven years ofage as compared to five (0.41) and three (0.35) years age group with a mean of 0.43 (p<0.05). Mean moisture content was 58.3% with no significant difference existing between the tree age groups. Fibre diameter (22.4 mm) was significantly lower (p<0.05) for the trees which were three years of age when compared to five and seven years age groups (26.6 mm and 24. 7 mm), respectively. Means of fibre length, lumen diameter and cell wall thickness were 0.83 mm, 18.3 mm, and 6.2 mm, respectively, with no significant differences detected between trees in all age groups. Further calculation on the coefficient of suppleness and runkel ratio suggest that wood from G.sepium may have the potential for insulation board manufacturing and paper making. However, future studies should experiment the utilisation of this species for these products to determine its full potential.


Sign in / Sign up

Export Citation Format

Share Document