Nonlinear Propagation of Amplitude-Modulated Ultrasonic Wave in Composite Material

2010 ◽  
Vol 452-453 ◽  
pp. 757-760
Author(s):  
Shiro Biwa ◽  
Kazuyoshi Nagae ◽  
Claude Inserra ◽  
Eiji Matsumoto

Some nonlinear effects in the ultrasonic wave propagation in a unidirectional carbon/carbon (C/C) composite were examined experimentally. High-power amplitude-modulated longitudinal ultrasonic waves were sent to the C/C composite sample, and the nonlinear generation of low-frequency components was observed. Due to the heterogeneity and pre-existing damage of the composite, the carrier-wave component undergoes severe attenuation, and the low-frequency components were dominant in some situations. Such low-frequency components are found to grow in a nonlinear manner, and can be a useful source of information characterizing the nonlinearity of the material.

2021 ◽  
Author(s):  
◽  
Andrew Paul Dawson

<p>The influence of highly regular, anisotropic, microstructured materials on high frequency ultrasonic wave propagation was investigated in this work. Microstructure, often only treated as a source of scattering, significantly influences high frequency ultrasonic waves, resulting in unexpected guided wave modes. Tissues, such as skin or muscle, are treated as homogeneous by current medical ultrasound systems, but actually consist of highly anisotropic micron-sized fibres. As these systems increase towards 100 MHz, these fibres will significantly influence propagating waves leading to guided wave modes. The effect of these modes on image quality must be considered. However, before studies can be undertaken on fibrous tissues, wave propagation in more ideal structures must be first understood. After the construction of a suitable high frequency ultrasound experimental system, finite element modelling and experimental characterisation of high frequency (20-200 MHz) ultrasonic waves in ideal, collinear, nanostructured alumina was carried out. These results revealed interesting waveguiding phenomena, and also identified the potential and significant advantages of using a microstructured material as an alternative acoustic matching layer in ultrasonic transducer design. Tailorable acoustic impedances were achieved from 4-17 MRayl, covering the impedance range of 7-12 MRayl most commonly required by transducer matching layers. Attenuation coefficients as low as 3.5 dBmm-1 were measured at 100 MHz, which is excellent when compared with 500 dBmm-1 that was measured for a state of the art loaded epoxy matching layer at the same frequency. Reception of ultrasound without the restriction of critical angles was also achieved, and no dispersion was observed in these structures (unlike current matching layers) until at least 200 MHz. In addition, to make a significant step forward towards high frequency tissue characterisation, novel microstructured poly(vinyl alcohol) tissue-mimicking phantoms were also developed. These phantoms possessed acoustic and microstructural properties representative of fibrous tissues, much more realistic than currently used homogeneous phantoms. The attenuation coefficient measured along the direction of PVA alignment in an example phantom was 8 dBmm-1 at 30 MHz, in excellent agreement with healthy human myocardium. This method will allow the fabrication of more realistic and repeatable phantoms for future high frequency tissue characterisation studies.</p>


Author(s):  
Arvi Ravasoo

The problem of ultrasonic nondestructive evaluation (NDE) of inhomogeneous prestress field is studied theoretically for an elastic material and plane strain. The nonlinear effects of ultrasonic wave propagation and interaction are shown to be additional sources of information for NDE. A model problem of simultaneous propagation of two ultrasonic longitudinal waves in physically nonlinear elastic material undergoing two-parametric prestress state is solved. The corresponding analytical solution is derived. Results of numerical simulations lead to the conclusion that it is possible to propose an algorithm for NDE of the inhomogeneous prestress field on the basis of the recorded data of boundary oscillations evoked by simultaneous propagation of two ultrasonic waves. The analysis of the oscillating boundary profiles permits to determine qualitatively the presence of prestress in the material and to distinguish special cases of the prestress state, for example, to evaluate quantitatively the parameters of the prestress.


2012 ◽  
Vol 39 (4) ◽  
pp. 484-493 ◽  
Author(s):  
Fernando Tallavo ◽  
Mahesh D. Pandey ◽  
Giovanni Cascante

Wood poles are widely used in North America to support power electric transmission and distribution lines. Wood poles are continuously exposed to wide ranging temperature and moisture conditions, making them vulnerable to internal decay and rotting. The resulting loss of strength makes the poles vulnerable to failure under adverse weather conditions, such as wind and snow storms. These failures can result in forced outages and customer disruptions with significant economic losses. Ultrasonic testing is a non-destructive method that has been used for detection of internal deterioration of in-service wood poles, which is based on the comparison of the measured wave velocity with a reference wave velocity associated with sound wood. The current ultrasonic methods assume that the reference wave velocity for a given wood species is constant in a pole cross section. This approach is simplistic because wood is an orthotropic material with highly variable material properties. This paper presents a method for probabilistic characterization of ultrasonic wave propagation in wood poles considering wood as an orthotropic material. A better understanding and characterization of ultrasonic wave propagation in a pole cross section will contribute to improve the condition assessment of in-service wood poles based on ultrasonic tests. As an example, P-wave velocity, surface waves, frequency response function, and magnitude spectrum area are used to characterize the propagation of ultrasonic waves at a cross section of a Douglas-fir pole of 25 cm diameter.


Sensors ◽  
2020 ◽  
Vol 20 (18) ◽  
pp. 5329
Author(s):  
Dai Quoc Tran ◽  
Ju-Won Kim ◽  
Kassahun Demissie Tola ◽  
Wonkyu Kim ◽  
Seunghee Park

The application of deep learning (DL) algorithms to non-destructive evaluation (NDE) is now becoming one of the most attractive topics in this field. As a contribution to such research, this study aims to investigate the application of DL algorithms for detecting and estimating the looseness in bolted joints using a laser ultrasonic technique. This research was conducted based on a hypothesis regarding the relationship between the true contact area of the bolt head-plate and the guided wave energy lost while the ultrasonic waves pass through it. First, a Q-switched Nd:YAG pulsed laser and an acoustic emission sensor were used as exciting and sensing ultrasonic signals, respectively. Then, a 3D full-field ultrasonic data set was created using an ultrasonic wave propagation imaging (UWPI) process, after which several signal processing techniques were applied to generate the processed data. By using a deep convolutional neural network (DCNN) with a VGG-like architecture based regression model, the estimated error was calculated to compare the performance of a DCNN on different processed data set. The proposed approach was also compared with a K-nearest neighbor, support vector regression, and deep artificial neural network for regression to demonstrate its robustness. Consequently, it was found that the proposed approach shows potential for the incorporation of laser-generated ultrasound and DL algorithms. In addition, the signal processing technique has been shown to have an important impact on the DL performance for automatic looseness estimation.


Materials ◽  
2020 ◽  
Vol 13 (12) ◽  
pp. 2684 ◽  
Author(s):  
Francesca Lionetto ◽  
Francesco Montagna ◽  
Alfonso Maffezzoli

Out-of-plane permeability of reinforcement preforms is of crucial importance in the infusion of large and thick composite panels, but so far, there are no standard experimental methods for its determination. In this work, an experimental set-up for the measurement of unsaturated through thickness permeability based on the ultrasonic wave propagation in pulse echo mode is presented. A single ultrasonic transducer, working both as emitter and receiver of ultrasonic waves, was used to monitor the through thickness flow front during a vacuum assisted resin infusion experiment. The set-up was tested on three thick carbon fiber preforms, obtained by stacking thermal bonding of balanced or unidirectional plies either by automated fiber placement either by hand lay-up of unidirectional plies. The ultrasonic data were used to calculate unsaturated out-of-plane permeability using Darcy’s law. The permeability results were compared with saturated out-of-plane permeability, determined by a traditional gravimetric method, and validated by some analytical models. The results demonstrated the feasibility and potential of the proposed set-up for permeability measurements thanks to its noninvasive character and the one-side access.


Author(s):  
Yasuhiro Sugimoto ◽  
Tatsuya Haruna ◽  
Keiichi Sato

It is important to separate and collect particles from solid-liquid mixture in order to reduce in environmental load and treatment cost of waste fluid. In this study, we try to separate and collect particles from the mixture by ultrasonic waves with relatively low frequency. In the present report, we use slurry of alumina abrasive as removal particles that use for polish and water jet cutting, etc. The particles are fully stirred in test water and then ultrasonic waves are irradiated with some frequencies. The particles behavior observed by a high-speed video camera is analyzed by a time series image analysis and correlated with sound pressure distribution. Particles flocculate to some layers like white bands that correspond to node of sound pressure after irradiation of ultrasonic wave. It is found that particles begin to move just after ultrasonic wave irradiation and flocculate clearly with the increase in sound pressure.


1973 ◽  
Vol 51 (12) ◽  
pp. 1350-1358 ◽  
Author(s):  
J. Vrba ◽  
R. R. Haering

An analysis of phonon maser action in CdS is given which includes the complications arising from the presence of off-axis ultrasonic waves. The treatment includes the angular variation of the velocity of sound and of the piezoelectric coupling constant and takes account of mode conversion at the cavity walls. Numerical results are given for CdS maser structures.


2021 ◽  
Author(s):  
◽  
Andrew Paul Dawson

<p>The influence of highly regular, anisotropic, microstructured materials on high frequency ultrasonic wave propagation was investigated in this work. Microstructure, often only treated as a source of scattering, significantly influences high frequency ultrasonic waves, resulting in unexpected guided wave modes. Tissues, such as skin or muscle, are treated as homogeneous by current medical ultrasound systems, but actually consist of highly anisotropic micron-sized fibres. As these systems increase towards 100 MHz, these fibres will significantly influence propagating waves leading to guided wave modes. The effect of these modes on image quality must be considered. However, before studies can be undertaken on fibrous tissues, wave propagation in more ideal structures must be first understood. After the construction of a suitable high frequency ultrasound experimental system, finite element modelling and experimental characterisation of high frequency (20-200 MHz) ultrasonic waves in ideal, collinear, nanostructured alumina was carried out. These results revealed interesting waveguiding phenomena, and also identified the potential and significant advantages of using a microstructured material as an alternative acoustic matching layer in ultrasonic transducer design. Tailorable acoustic impedances were achieved from 4-17 MRayl, covering the impedance range of 7-12 MRayl most commonly required by transducer matching layers. Attenuation coefficients as low as 3.5 dBmm-1 were measured at 100 MHz, which is excellent when compared with 500 dBmm-1 that was measured for a state of the art loaded epoxy matching layer at the same frequency. Reception of ultrasound without the restriction of critical angles was also achieved, and no dispersion was observed in these structures (unlike current matching layers) until at least 200 MHz. In addition, to make a significant step forward towards high frequency tissue characterisation, novel microstructured poly(vinyl alcohol) tissue-mimicking phantoms were also developed. These phantoms possessed acoustic and microstructural properties representative of fibrous tissues, much more realistic than currently used homogeneous phantoms. The attenuation coefficient measured along the direction of PVA alignment in an example phantom was 8 dBmm-1 at 30 MHz, in excellent agreement with healthy human myocardium. This method will allow the fabrication of more realistic and repeatable phantoms for future high frequency tissue characterisation studies.</p>


Sign in / Sign up

Export Citation Format

Share Document