Dissolution of Precipitates in Hot Rolled Low Mn, Ti Added Pipeline Steels

2010 ◽  
Vol 638-642 ◽  
pp. 3182-3187 ◽  
Author(s):  
Ali Dehghan-Manshadi ◽  
Rian Dippenaar

The dissolution of different sulphides, carbides, carbo-sulphides and nitrides during re-heating of hot rolled low carbon, low manganese, titanium added steel have been studied using transmission electron microscopy (TEM), scanning electron microscopy (SEM) and energy dispersive spectrometry (EDS) analysis. In addition, the chemical composition and size distribution of the different precipitates have been determined before and after reheating to analyze the modification of these precipitates in the course of the reheating cycle. The TEM and EDS analyses showed the presence of a wide variety of simple and/or complex precipitates in as rolled samples. The reheating of these samples to temperatures as high as 1350 °C, caused dissolution of most particles, although titanium nitride (TiN) did not dissolve even after reheating. By decreasing the reheating temperature more and more precipitates remained un-dissolved, but some spherodization occurred at higher temperatures.

2015 ◽  
Vol 229 ◽  
pp. 3-10 ◽  
Author(s):  
Bartłomiej Dybowski ◽  
Bogusława Adamczyk-Cieślak ◽  
Kinga Rodak ◽  
Iwona Bednarczyk ◽  
Andrzej Kiełbus ◽  
...  

The complex microstructure of as-cast AlSi7Mg alloy has been investigated. Microstructure observations were done using light microscopy, scanning electron microscopy and transmission electron microscopy. Chemical composition of the microstructure constituents was investigated by means of energy dispersive spectrometry, conducted both during SEM and STEM investigations. Selected area diffraction was used to identify the phases in the alloy. Microstructure of the alloy in the as-cast condition consists of Al-Si eutectic and intermetallic phases in the interdendritic regions. These are: Mg2Si, α-AlFeMnS, β-AlFeSi and π-AlFeSiMg phases. What is more, number of fine precipitates were found within the α-Al dendrites. Only the occurrence of U1 (MgAl2Si2) phase has been confirmed.


2015 ◽  
Vol 34 (8) ◽  
Author(s):  
Wei-Jian Liu ◽  
Jing Li ◽  
Cheng-Bin Shi ◽  
Xiang-Dong Huo

AbstractThe effect of boron and titanium addition on the hot ductility of Nb-containing steel was investigated using hot tensile tests. The fracture surface and the quenched longitudinal microstructure were examined by optical microscopy (OM), scanning electron microscopy (SEM) and transmission electron microscopy (TEM). The results showed that both steel samples had the similar change from 1,100°C to 700°C. The hot ductility of Nb-containing steel with boron and titanium addition was higher than the steel without boron and titanium in the temperature range of 900–750°C. Because the formation of intergranular ferrite was inhibited by solute boron segregating on the grain boundary, the formation of TiN changed the distribution of Nb- and boron-containing precipitates and improved the amount of intragranular ferrite.


Author(s):  
Nakazo Watari ◽  
Yasuaki Hotta ◽  
Yoshio Mabuchi

It is very useful if we can observe the identical cell elements within the same sections by light microscopy (LM), transmission electron microscopy (TEM) and/or scanning electron microscopy (SEM) sequentially, because, the cell fine structure can not be indicated by LM, while the color is; on the other hand, the cell fine structure can be very easily observed by EM, although its color properties may not. However, there is one problem in that LM requires thick sections of over 1 μm, while EM needs very thin sections of under 100 nm. Recently, we have developed a new method to observe the same cell elements within the same plastic sections using both light and transmission (conventional or high-voltage) electron microscopes.In this paper, we have developed two new observation methods for the identical cell elements within the same sections, both plastic-embedded and paraffin-embedded, using light microscopy, transmission electron microscopy and/or scanning electron microscopy (Fig. 1).


Author(s):  
Venita F. Allison ◽  
J. E. Ubelaker ◽  
J. H. Martin

It has been suggested that parasitism results in a reduction of sensory structures which concomitantly reflects a reduction in the complexity of the nervous system. The present study tests this hypothesis by examining the fine morphology and the distribution of sensory receptors for two species of aspidogastrid trematodes by transmission and scanning electron microscopy. The species chosen are an ectoparasite, Cotylaspis insignis and an endoparasite, Aspidogaster conchicola.Aspidogaster conchicola and Cotylaspis insignis were obtained from natural infections of clams, Anodonta corpulenta and Proptera purpurata. The specimens were fixed for transmission electron microscopy in phosphate buffered paraformaldehyde followed by osmic acid in the same buffer, dehydrated in an ascending series of ethanol solutions and embedded in Epon 812.


Author(s):  
Thomas P. Turnbull ◽  
W. F. Bowers

Until recently the prime purposes of filters have been to produce clear filtrates or to collect particles from solution and then remove the filter medium and examine the particles by transmission electron microscopy. These filters have not had the best characteristics for scanning electron microscopy due to the size of the pores or the surface topography. Advances in polymer chemistry and membrane technology resulted in membranes whose characteristics make them versatile substrates for many scanning electron microscope applications. These polysulphone type membranes are anisotropic, consisting of a very thin (0.1 to 1.5 μm) dense skin of extremely fine, controlled pore texture upon a much thicker (50 to 250μm), spongy layer of the same polymer. Apparent pore diameters can be controlled in the range of 10 to 40 A. The high flow ultrafilters which we are describing have a surface porosity in the range of 15 to 25 angstrom units (0.0015-0.0025μm).


Author(s):  
John F. Mansfield

The current imaging trend in optical microscopy, scanning electron microscopy (SEM) or transmission electron microscopy (TEM) is to record all data digitally. Most manufacturers currently market digital acquisition systems with their microscope packages. The advantages of digital acquisition include: almost instant viewing of the data as a high-quaity positive image (a major benefit when compared to TEM images recorded onto film, where one must wait until after the microscope session to develop the images); the ability to readily quantify features in the images and measure intensities; and extremely compact storage (removable 5.25” storage devices which now can hold up to several gigabytes of data).The problem for many researchers, however, is that they have perfectly serviceable microscopes that they routinely use that have no digital imaging capabilities with little hope of purchasing a new instrument.


Sign in / Sign up

Export Citation Format

Share Document