Fresh Whole Blood Transfusion: Military and Civilian Implications

2016 ◽  
Vol 36 (3) ◽  
pp. 50-57 ◽  
Author(s):  
Carl W. Goforth ◽  
John W. Tranberg ◽  
Phillip Boyer ◽  
Peter J. Silvestri

Uncontrolled hemorrhage and exsanguination are the leading cause of preventable death, and resuscitative therapy is a critical component for survival. In various combinations, fresh whole blood, blood components, colloids, and crystalloids have all been staples of trauma care. The use of fresh whole blood is a well-established military practice that has saved the lives of thousands of American and coalition military personnel. Civilian use of fresh whole blood is far less established owing to the wide availability of individual blood components. However, this highly tailored blood supply is vulnerable to both natural and man-made disasters. In the event of such disruption, such as a major hurricane, it may be necessary for civilian hospitals to rapidly enact a fresh whole blood program. Therefore, the aim of this article is to review the current use of blood therapy for trauma resuscitation, the US military’s approach to fresh whole blood, and how maintaining a civilian capacity for fresh whole blood collection in the event of future man-made and natural disasters is key to promoting survival from trauma.

Hematology ◽  
2003 ◽  
Vol 2003 (1) ◽  
pp. 575-589 ◽  
Author(s):  
Christopher D. Hillyer ◽  
Cassandra D. Josephson ◽  
Morris A. Blajchman ◽  
Jaroslav G. Vostal ◽  
Jay S. Epstein ◽  
...  

Abstract Bacterial contamination of transfusion products, especially platelets, is a longstanding problem that has been partially controlled through modern phlebotomy practices, refrigeration of red cells, freezing of plasma and improved materials for transfusion product collection and storage. Bacterial contamination of platelet products has been acknowledged as the most frequent infectious risk from transfusion occurring in approximately 1 of 2,000–3,000 whole-blood derived, random donor platelets, and apheresis-derived, single donor platelets. In the US, bacterial contamination is considered the second most common cause of death overall from transfusion (after clerical errors) with mortality rates ranging from 1:20,000 to 1:85,000 donor exposures. Estimates of severe morbidity and mortality range from 100 to 150 transfused individuals each year. Concern over the magnitude and clinical relevance of this issue culminated in an open letter calling for the “blood collection community to immediately initiate a program for detecting the presence of bacteria in units of platelets.” Thereafter, the American Association of Blood Banks (AABB) proposed new standards to help mitigate transfusion of units that were contaminated with bacteria. Adopted with a final implementation date of March 1, 2004, the AABB Standard reads “The blood bank or transfusion service shall have methods to limit and detect bacterial contamination in all platelet components.” This Joint ASH and AABB Educational Session reviews the risks, testing strategies, and regulatory approaches regarding bacterial contamination of blood components to aid in preparing practitioners of hematology and transfusion medicine in understanding the background and clinical relevance of this clinically important issue and in considering the approaches currently available for its mitigation, as well as their implementation. In this chapter, Drs. Hillyer and Josephson review the background and significance of bacterial contamination, as well as address the definitions, conceptions and limitations of the terms risk, safe and safety. They then describe current transfusion risks including non-infectious serious hazards of transfusion, and current and emerging viral risks. In the body of the text, Dr. Blajchman reviews the prevalence of bacterial contamination in cellular blood components in detail with current references to a variety of important studies. He then describes the signs and symptoms of transfusion-associated sepsis and the sources of the bacterial contamination for cellular blood products including donor bacteremia, and contamination during whole blood collection and of the collection pack. This is followed by strategies to decrease the transfusion-associated morbidity/mortality risk of contaminated cellular blood products including improving donor skin disinfection, removal of first aliquot of donor blood, pre-transfusion detection of bacteria, reducing recipient exposure, and pathogen reduction/inactivation. In the final sections, Drs. Vostal, Epstein and Goodman describe the regulations and regulatory approaches critical to the appropriate implementation of a bacterial contamination screening and limitation program including their and/or the FDA’s input on prevention of bacterial contamination, bacterial proliferation, and detection of bacteria in transfusion products. This is followed by a discussion of sampling strategy for detection of bacteria in a transfusion product, as well as the current approval process for bacterial detection devices, trials recommended under “actual clinical use” conditions, pathogen reduction technologies, and bacterial detection and the extension of platelet storage.


2018 ◽  
Vol 88 (3-4) ◽  
pp. 151-157 ◽  
Author(s):  
Scott W. Leonard ◽  
Gerd Bobe ◽  
Maret G. Traber

Abstract. To determine optimal conditions for blood collection during clinical trials, where sample handling logistics might preclude prompt separation of erythrocytes from plasma, healthy subjects (n=8, 6 M/2F) were recruited and non-fasting blood samples were collected into tubes containing different anticoagulants (ethylenediaminetetra-acetic acid (EDTA), Li-heparin or Na-heparin). We hypothesized that heparin, but not EDTA, would effectively protect plasma tocopherols, ascorbic acid, and vitamin E catabolites (α- and γ-CEHC) from oxidative damage. To test this hypothesis, one set of tubes was processed immediately and plasma samples were stored at −80°C, while the other set was stored at 4°C and processed the following morning (~30 hours) and analyzed, or the samples were analyzed after 6 months of storage. Plasma ascorbic acid, as measured using HPLC with electrochemical detection (LC-ECD) decreased by 75% with overnight storage using EDTA as an anticoagulant, but was unchanged when heparin was used. Neither time prior to processing, nor anticoagulant, had any significant effects upon plasma α- or γ-tocopherols or α- or γ-CEHC concentrations. α- and γ-tocopherol concentrations remained unchanged after 6 months of storage at −80°C, when measured using either LC-ECD or LC/mass spectrometry. Thus, refrigeration of whole blood at 4°C overnight does not change plasma α- or γ-tocopherol concentrations or their catabolites. Ascorbic acid is unstable in whole blood when EDTA is used as an anticoagulant, but when whole blood is collected with heparin, it can be stored overnight and subsequently processed.


Transfusion ◽  
2021 ◽  
Vol 61 (S1) ◽  
Author(s):  
Julia H. Kolodziej ◽  
Julie C. Leonard ◽  
Cassandra D. Josephson ◽  
Barbara A. Gaines ◽  
Stephen R. Wisniewski ◽  
...  

2021 ◽  
Vol 14 (1) ◽  
Author(s):  
Ruby E. Harrison ◽  
Mark R. Brown ◽  
Michael R. Strand

Abstract Background Most female mosquitoes are anautogenous and must blood feed on a vertebrate host to produce eggs. Prior studies show that the number of eggs females lay per clutch correlates with the volume of blood ingested and that protein is the most important macronutrient for egg formation. In contrast, how whole blood, blood fractions and specific blood proteins from different vertebrates affect egg formation is less clear. Since egg formation is best understood in Aedes aegypti, we examined how blood and blood components from different vertebrates affect this species and two others: the malaria vector Anopheles gambiae and arbovirus vector Culex quinquefasciatus. Methods Adult female mosquitoes were fed blood, blood fractions and purified major blood proteins from different vertebrate hosts. Markers of reproductive response including ovary ecdysteroidogenesis, yolk deposition into oocytes and number of mature eggs produced were measured. Results Ae. aegypti, An. gambiae and C. quinquefasciatus responded differently to meals of whole blood, plasma or blood cells from human, rat, chicken and turkey hosts. We observed more similarities between the anthropophiles Ae. aegypti and An. gambiae than the ornithophile C. quinquefasciatus. Focusing on Ae. aegypti, the major plasma-derived proteins (serum albumin, fibrinogen and globulins) differentially stimulated egg formation as a function of vertebrate host source. The major blood cell protein, hemoglobin, stimulated yolk deposition when from pigs but not humans, cows or sheep. Serum albumins from different vertebrates also variably affected egg formation. Bovine serum albumin (BSA) stimulated ovary ecdysteroidogenesis, but more weakly induced digestive enzyme activities than whole blood. In contrast, BSA-derived peptides and free amino acids had no stimulatory effects on ecdysteroidogenesis or yolk deposition into oocytes. Conclusions Whole blood, blood fractions and specific blood proteins supported egg formation in three species of anautogenous mosquitoes but specific responses varied with the vertebrate source of the blood components tested.


Author(s):  
Alyssa R Lindrose ◽  
Indrani Mitra ◽  
Jamie Fraser ◽  
Edward Mitre ◽  
Patrick W Hickey

Abstract Background Helminth infections caused by parasitic worms, including nematodes (roundworms), cestodes (tapeworms) and trematodes (flukes), can cause chronic symptoms and serious clinical outcomes if left untreated. The US military frequently conducts activities in helminth-endemic regions, particularly Africa, the Middle East and Southeast Asia. However, the military does not currently screen for these infections, and to date, no comprehensive surveillance studies have been completed to assess the frequency of helminth diagnoses in the military personnel and their families. Methods To determine the burden of helminth infections in the US Military Health System (MHS), we conducted a retrospective analysis of International Classification of Diseases (ICD)-9/10 diagnosis codes from all medical encounters in the MHS Data Repository (MDR) from fiscal years (FY) 2012 to 2018. Chart reviews were conducted to assign ICD diagnoses as incorrect, suspected, probable or confirmed based on the laboratory results and symptoms. Results Abstraction of MHS data revealed over 50 000 helminth diagnoses between FY 2012 and FY 2018. Of these, 38 445 of diagnoses were amongst unique subjects. After chart review, we found there were 34 425 validated helminth infections diagnosed amongst the unique subjects of US military personnel, retirees and dependents. Nearly 4000 of these cases represented infections other than enterobiasis. There were 351 validated strongyloidiasis diagnoses, 317 schistosomiasis diagnoses and 191 diagnoses of cysticercosis during the study period. Incidence of intestinal nematode infection diagnoses showed an upward trend, whilst the incidence of cestode infection diagnoses decreased. Conclusions The results of this study demonstrate that helminth infections capable of causing severe morbidity are often diagnosed in the US military. As helminth infections are often asymptomatic or go undiagnosed, the true burden of helminth infections in US military personnel and dependents may be higher than observed here. Prospective studies of US military personnel deployed to helminth-endemic areas may be indicated to determine if post-deployment screening and/or empirical treatment are warranted.


Biology ◽  
2021 ◽  
Vol 10 (2) ◽  
pp. 133
Author(s):  
Isabella Oliveira Barros ◽  
Rejane Santos Sousa ◽  
Marcondes Dias Tavares ◽  
Renato Otaviano Rêgo ◽  
Paulo Ricardo Firmino ◽  
...  

Hemotherapy using whole blood and its components is being increasingly used in veterinary therapy. Since it is important to store animal blood while maintaining acceptable hematological, blood gas, and biochemical characteristics, increasing our knowledge of available technologies for strategic blood storage is imperative. Thus, we aimed to assess the hematological, blood gas, and biochemical changes in donkey whole blood using blood bags with two different types of storage agents. Eight adult healthy male donkeys were used; 900 mL of blood was collected from each, with 450 mL stored in citrate-phosphate-dextrose and adenine bags (CPDA-1) and 450 mL stored in bags containing citrate-phosphate-dextrose, adenine, mannitol, and sodium chloride (CPD/SAG-M). Both bags were kept refrigerated between 1 and 6 °C for 42 days. Blood samples were removed from the bags eight times (T): T0 (immediately after blood collection), T1, T3, T7, T14, T21, T35, and T42 (1, 3, 7, 14, 21, 35 and 42 days after storage). Hematological, blood gas, biochemical, and microbiological parameters were assessed. The CPDA-1 bags had a higher packed cell volume when compared to CPD/ SAG-M. The red blood cell count reduced by around 19% in both the bags due to hemolysis, which was confirmed by an increase in plasma hemoglobin. The white blood cell count; pH; concentrations of glucose, sodium, bicarbonate, and 2,3 diphosphoglycerate were reduced in both bags. Meanwhile, pO2, pCO2, lactate dehydrogenase, and levels of potassium increased in the CPDA-1 and CPD/SAG-M bags. Blood bags were efficient for the storage of donkey blood for up to 42 days.


2005 ◽  
Author(s):  
Hans C. Fischer ◽  
Eliseo Papa ◽  
Lichuan Liu ◽  
K. Sandy Pang ◽  
Warren C. W. Chan

2003 ◽  
Vol 49 (2) ◽  
pp. 275-280 ◽  
Author(s):  
Kazunari Yamaguchi ◽  
Yuji Yonemura ◽  
Hiroaki Okabe ◽  
Yoichi Takahama ◽  
Shinya Nagai ◽  
...  

Abstract Background: Assays to screen for and confirm the presence of the antibody for human T-lymphotropic virus type I (HTLV-I) are currently performed with serum or plasma. We developed and evaluated a new counting immunoassay (CIA) for the detection of HTLV-I antibody in whole blood, using recombinant and synthetic peptide antigens. Methods: We assessed the CIA for detection of HTLV-I antibody in whole blood and plasma. The CIA is an immunity-measuring method that combines latex agglutination with particle-counting technology. The numbers of agglutinated latex particles, single latex particles, and blood cells in a sample are measured based on differences in particle size between latex particles and blood cells. Results: The CIA and ELISA methods were in agreement for all 24 plasma samples tested, including those from 6 patients with HTLV-I-associated diseases, 6 HTLV-I carriers, and 12 HTLV-I antibody-negative individuals. The concordance between the ELISA (plasma) and the CIA (whole blood) for samples from 24 patients was 100%. The concordance between a particle agglutination method (plasma) and the CIA (plasma or whole blood) for 1065 patients was 99.5%. The concordance between results obtained for 1065 pairs of plasma and whole blood samples with the CIA method was 100%. HTLV-I antibody in whole blood was stable for 3 days after blood collection. With this CIA method, results were available within 15 min. Conclusions: The CIA method can be used in screening for HTLV-I. The use of whole blood rather than serum or plasma reduces the sample volume and number of blood collections required, as well as assay time.


Blood ◽  
2008 ◽  
Vol 112 (11) ◽  
pp. 999-999
Author(s):  
Fabiola Grizzatti ◽  
Melissa A Qazi ◽  
David Stroncek ◽  
Nathawut Sibmooh ◽  
Barbora Piknova ◽  
...  

Abstract In light of recent papers stressing the importance of decreased levels of SNO-hemoglobin (SNO-Hb) to the pronounced nature of deleterious effects of transfusion of stored red blood cells (RBCs), there has been an increased interest in the practice of blood storage. Dejam et al. (Blood, 2005) previously demonstrated the critical nature of RBCs in NO physiology: they serve as the major intravascular stores of nitrite, which is eventually converted to NO, an important player in vasoregulation. The purpose of this study is to quantify the NO metabolites, nitrite and nitrate, in three blood components and evaluate their levels over time of storage. Blood obtained from 6 healthy volunteer donors was split into whole blood, leukoreduced, and non-leukoreduced packed RBCs and stored in polyvinyl chloride (PVC) bags for 42 days at 4°C. PVC bags were maintained in either room air or an argon chamber. Nitrite, nitrate, and SNO-Hb/nitrosyl-hemoglobin (HbNO) were measured using reductive gas-phase chemiluminescence. In all blood components, the nitrite and nitrate were detected in higher concentrations in RBCs than in the extracellular fluid compartment. Mean nitrite value immediately before storage was 152±13nM, but fell rapidly upon storage. Nitrite levels continued to decrease with storage time, while nitrate levels remained constant for the duration of storage. In the leukoreduced blood product, nitrite levels were 75±8nM on day 1 and 50±9nM by day 42; the concentration of nitrate in the leukoreduced blood product was 34±3uM on day 1 and 34±4uM on day 42. The nitrite levels in non-leukoreduced blood product were 76±12nM on day 1 and 37±7 by day 42; the nitrate concentration in the non-leukoreduced blood product was 35±3uM on day 1 and 32±0.4uM on day 42. In whole blood, nitrite levels were 64±11nM on day 1 and 44±9nM by day 42; the nitrate concentration was 47±2uM on day 1 and 43±6uM on day 42. SNO-Hb levels were very low in fresh blood and virtually undetectable after one day of storage. Interestingly, nitrite levels never reached zero. Enzyme inhibitors—L-NAME (nitric oxide synthase inhibitor), acetazolamide (carbonic anhydrase inhibitor), and oxypurinol (xanthine oxidase inhibitor)—did not lower nitrite levels enough to explain the remaining nitrite present in the PVC bags after 42 days. pH decreased slightly, while pO2 increased in all three components during storage; this is likely due to the diffusion of oxygen from room air into the PVC bags. Control experiments with saline showed an increase in nitrite levels, while nitrate levels remained stable over 42 days. When stored in an argon chamber, both blood and saline samples showed relatively lower nitrite levels than their room air counterparts. Thus, during blood bank storage, nitrite levels decrease in blood while nitrate levels remain stable. The diffusion of nitrogenous gases may explain why nitrite does not completely disappear under standard storage conditions. Our results suggest that most of the NO pathway is initially retained, but greater changes occur with prolonged storage. These measurements of NO derivatives may have implications for transfusion therapy, explaining some of the adverse effects seen with RBC transfusion and providing a foundation for enhancing blood preservation through improvement of storage practices.


Sign in / Sign up

Export Citation Format

Share Document