scholarly journals Effect of denture cleansers on color stability and surface roughness of denture base acrylic resin

2015 ◽  
Vol 26 (2) ◽  
pp. 163 ◽  
Author(s):  
HamidrezaRajati Haghi ◽  
Nafiseh Asadzadeh ◽  
Rasul Sahebalam ◽  
Mohammadreza Nakhaei ◽  
JamalZamani Amir
2013 ◽  
Vol 24 (2) ◽  
pp. 152-156 ◽  
Author(s):  
Helena de Freitas Oliveira Paranhos ◽  
Amanda Peracini ◽  
Marina Xavier Pisani ◽  
Viviane de Cássia Oliveira ◽  
Raphael Freitas de Souza ◽  
...  

This study evaluated color stability, surface roughness and flexural strength of acrylic resin specimens after immersion in alkaline peroxide and alkaline hypochlorite, simulating a period of one and a half year of use of overnight immersion. Sixty disc-shaped (16X4 mm) and 80 rectangular specimens (65X10X3.3 mm) were prepared from heat-polymerized acrylic resin (Lucitone 550) and distributed into 4 groups (n=20): C1: without immersion, C2: 8 h immersion in distilled water; AP: 8 h immersion in alkaline peroxide effervescent tablet; SH: 8 h immersion in 0.5% NaOCl solution. Properties were evaluated at baseline and after the immersion. Color data were also calculated according the National Bureau of Standards (NBS). Results were analyzed statistically by ANOVA and Tukey's HSD test (α=0.05). AP (2.34 ± 0.41) caused color alteration significantly higher than C2 (0.39 ± 0.30) and SH (1.73 ± 0.52). The mean ΔE values were classified as indicial for C2 (0.36 ± 0.29) and noticeable for AP (2.12 ± 0.39) and SH (1.59 ± 0.48). SH (0.0195 ± 0.0150) caused significantly higher ΔRa (p=0.000) than the C2 (0.0005 ± 0.0115) and PA (0.0005 ± 0.0157) groups. There was no statistically significant difference (p=0.063) among the solutions for flexural strength (C1: 105.43 ± 14.93, C2: 100.30 ± 12.43, PA: 97.61 ± 11.09, SH: 95.23 ± 10.18). In conclusion, overnight immersion in denture cleansing solutions simulating a year and a half of use did not alter the flexural strength of acrylic resin but caused noticeable color alterations, higher for alkaline peroxide. The 0.5% NaOCl solution caused increase in surface roughness.


2021 ◽  
Vol 2021 ◽  
pp. 1-10
Author(s):  
Mohammed M. Gad ◽  
Reem Abualsaud ◽  
Shaimaa M. Fouda ◽  
Ahmed Rahoma ◽  
Ahmad M. Al-Thobity ◽  
...  

Statement of Problem. Novel polymethyl methacrylate (PMMA) containing zirconium dioxide nanoparticles (nano-ZrO2) was suggested as a denture base material but there is a lack of information regarding denture cleanser effects. Objectives. This study aimed to evaluate denture cleanser effects on color stability, surface roughness, and hardness of PMMA denture base resin reinforced with nano-ZrO2. Materials and Methods. A total of 420 specimens were fabricated of unreinforced and nano-ZrO2 reinforced acrylic resin at 2.5% and 5%, resulting in 3 main groups. These groups were further subdivided (n = 10) according to immersion solution (distilled water, Corega, sodium hypochlorite, and Renew) and immersion duration. Surface roughness, hardness, and color were measured at baseline (2 days-T0) in distilled water and then after 180 and 365 days of immersion (T1 & T2) in water or denture cleansing solutions. Data was collected and analyzed using two-way ANOVA followed by Bonferroni post hoc test (α = 0.05). Results. Surface roughness increased significantly after denture cleanser immersion of unmodified and nano-ZrO2-modified PMMA materials while hardness decreased ( P < 0.001 ). The denture cleansers significantly affected the color of both PMMA denture bases ( P < 0.001 ). The immersion time in denture cleansers significantly affected all tested properties ( P < 0.001 ). Within denture cleansers, NaOCl showed the highest adverse effects ( P < 0.05 ) while Renew showed the least adverse effects. Conclusion. Denture cleansers can significantly result in color change and alter the surface roughness and hardness of denture base resin even with ZrO2 nanoparticles addition. Therefore, they should be carefully used.


2018 ◽  
Vol 2 (2) ◽  
pp. 162-173
Author(s):  
Mahabad Saleh ◽  
Salem Salem

Background and Objectives: Denture cleanser is the most widely used method by the patients to maintain clean and healthy dentures but the prolonged use of such cleansers may affect the properties of the denture. The present study was carried out to evaluate the effect of three prepared denture cleansers which were the 4% citric acid, 4% tartaric acid, and 4% oxalic acid in addition to the Protefix a commercially available denture cleansers, on some mechanical and physical properties (color stability, water sorption, and solubility) of acrylic resin (Stellon QC-20) and flexible nylon (Vaplast) denture base materials after immersion in tea solution. Methods: One hundred specimens (100) were prepared in two equal major groups: acrylic resin and Valplast. For each test of the physical and mechanical properties, 50 specimens were prepared, 25 from acrylic resin and 25 from Valplast. Later on, divided into five groups, one group used as a control and immersed in distilled water, and remaining 4 groups used as test groups; by immersing in one of the denture cleansers after staining in tea solutions for 10 days. The effect of denture cleansers on the properties was studied and compared with the control group. Results: Visual examination method showed no color changes for acrylic and slight color change for valplast specimens. Valplast specimens showed higher water sorption and solubility than acrylic. Conclusions: The findings showed that the 4 denture cleansers were equally effective, and did not cause significant alteration in the tested properties. Except acrylic specimens immersed in oxalic acid showed less color stability.


2009 ◽  
Vol 101 (3) ◽  
pp. 205-213 ◽  
Author(s):  
Guang Hong ◽  
Hiroshi Murata ◽  
YingAi Li ◽  
Sinshuke Sadamori ◽  
Taizo Hamada

2016 ◽  
Vol 4 (3) ◽  
pp. 476-481 ◽  
Author(s):  
Amani Ramadan Moussa ◽  
Wessam Mohamed Dehis ◽  
Asmaa Nabil Elboraey ◽  
Hisham Samir ElGabry

AIM: This study aimed to verify the influence of oral environment and denture cleansers on the surface roughness and hardness of two different denture base materials. METHODS: A total of sixteen identical removable disc specimens (RDS) were processed. Eight RDS were made from heat-cured acrylic resin (AR) and the other eight were fabricated from thermoplastic injection moulded resin (TR). Surface roughness and hardness of DRS were measured using ultrasonic profilometry and Universal testing machine respectively. Then the four RDS (two AR and two of TR) were fixed to each maxillary denture, after three months RDS were retrieved. Surface roughness and hardness of RDS have measured again.RESULTS: The surface roughness measurements revealed no significant difference (p >0.05) for both disc groups at baseline. However, both groups showed a significant increase in the surface roughness after three months with higher mean value for (TR) group. On the other hand, the (AR) group showed higher hardness mean value than (TR) group at baseline with no significant decrease in the hardness values (p >0.05) following three months follow-up period. CONCLUSIONS: Denture cleansers have an effect on the denture’s surface roughness and hardness concurrently with an oral condition which will consequently influence the complete dentures’ lifetime and patients’ satisfaction.


2021 ◽  
Vol 17 (1) ◽  
pp. 22-26
Author(s):  
Kadek Ayu Wirayuni ◽  
◽  
I Made Hendri Dwi Saputra ◽  

Introduction: The denture base is the part of the removable denture that is supported by good adaptation to the underlying oral tissue. Most of the denture bases are made of acrylic or polymethyl methacrylate resin, better known as PMMA. However, the acrylic resin also has disadvantages such as easily broken and absorbs liquids both water and chemicals. The chemical absorption like alcohol, ethanol, and some drinks that contain acidic materials will chemically be induced with acrylic resin and settle in the pores of the acrylic resin. The chemical damage or defect creates roughness on the surface of the acrylic resin which can cause cracking or crazing and a decrease in surface strength and hardness. Materials and Methods: The method used in this research was a laboratory experimental design with a post-test-only control group using 12 samples consisting of 2 different types of samples by measuring the surface roughness of the acrylic resin after immersing the sample with a predetermined time. Results and Discussions: One-way ANOVA test results showed a significant difference in surface roughness after the samples immersion with a value of p = 0.006 (p <0.05). Conclusions: Based on this research, can be concluded that there is an increase in the surface roughness of the heated polymerized acrylic resin for 3 hours and 4 hours of immersion. The longer the heated polymerized acrylic resin is soaked in arak hence the level of surface roughness increases.


Sign in / Sign up

Export Citation Format

Share Document