scholarly journals Measurement of Effective Thermal Conductivity of Cupra and Polyester Fiber Assemblies in Low Fiber Volume Fraction

2016 ◽  
Vol 62 (5) ◽  
pp. 105-116
Author(s):  
Morihiro YONEDA ◽  
Chie NAKAJIMA
Author(s):  
Jessica N. McClay ◽  
Peter Joyce ◽  
Andrew N. Smith

Measurements of the in-plane thermal conductivity and the directional dependence of Mitsubishi K63B12 pitch-fiber/Epoxy composite from Newport Composites are reported. This composite is being explored for use in the Avanced Seal Delivery System for effective thermal management. The thermal conductivity was measured using a steady state technique. The experimental results were then compared to a model of the thermal conductivity based on the direction of the fibers. These estimates are based on the properties of the constituent materials and volume of fibers in the sample. Therefore the density and the fiber volume fraction were experimentally measured. The thermal conductivity is clearly greatest in the direction of the fibers and decreases as the fibers are rotated off axis. In the case of pitch fiber composite materials, the contribution of the fibers to the thermal conductivity dominates. The experimental data clearly followed the correct trends; however, the measured values were 25% to 35% lower than predicted.


2014 ◽  
Vol 936 ◽  
pp. 154-163
Author(s):  
Rui Xu ◽  
Jun Kui Mao ◽  
Jing Yu Zhang ◽  
De Cang Lou ◽  
Wen Guo

The prediction of fiber reinforced ceramic is one of the most important procedure when investigating the application of ceramic composite. Numerical simulations were applied and a novel model was brought out in this paper. Firstly, four different models for predicting thermal conductivities of unidirectional fiber reinforced materials were compared, which include the Rayleigh,LN,ST and TE model,. It shows that Rayleigh model and LN model have good precision only in low fiber volume content cases. There existed big differences between the experimental and numerical results if predicted the high fiber volume content with either these four models. Then a novel model based on LN model was studied with the correction of the representative volume element method. Further comparison results indicate that the error can be reduced as 55.6% with this novel model. At the same time, the longitudinal (k11) and transverse (k22) thermal conductivities predicted by the novel model were also analyzed. It was found thatk11had a linear relationship with fiber volume fraction and thermal conductivity ratio (p). Butk22had a nonlinear relationship with fiber volume fraction, which increased much greatly when fiber volume fraction increasing at high fiber volume fraction andp>1.


2005 ◽  
Author(s):  
Hossein Golestanian

Models are presented for the determination of thermal conductivity of a composite lamina with woven fiber mats. In analyzing the cure cycle of a composite part, the common practice has been to use weight-averaged thermal properties. The limitation of this approach becomes apparent when one finds that thermal conductivity calculated for fiberglass/epoxy composite is very close to thermal conductivity of carbon/epoxy composite. This happens for composite parts with the same fiber volume fraction. In weight-average formulations the effect of fiber thermal conductivity is overshadowed by the density of the constituents. To overcome this problem, one needs to take another approach. In this investigation finite element analysis is performed to determine thermal conductivities of fiberglass/epoxy and carbon/epoxy composite lamina. The resulting thermal conductivities are different for the two composite types. These results make more physical sense since thermal conductivity of carbon fiber mat is much higher than that of fiberglass mat.


2015 ◽  
Vol 799-800 ◽  
pp. 794-799 ◽  
Author(s):  
Sebti Jaballi ◽  
Imed Miraoui ◽  
Hedi Hassis

This paper focuses on the optimization of flexural strength and thermal conductivity of mortar reinforced with Alfa fibers. Fibers were manually extracted from Alfa leafs to avoid the risk of degradation of mechanical properties. A first group of samples (300 x 300 x 30 mm) having a fiber volume fraction of 0.5 to 1.5% is prepared to measure the thermal conductivity.The second composite family (40 x 40 x 160 mm) cured in a wet chamber is used for measuring its bending strength. The fiber percentage varies from 0.74 to 1,85%.The results show that the thermal conductivity decreases by increasing the fiber content. While the optimal percentage of fiber for the flexural strength is estimated at 1%, corresponding to an increase of 27% in strength.


2015 ◽  
Vol 137 (3) ◽  
Author(s):  
Iman Eslami Afrooz ◽  
Andreas Öchsner

Finite element analysis has been employed to investigate the effect of carbon nanotubes (CNTs) distribution on the thermal conductivity of composite materials. Several kinds of representative volume elements (RVEs) employed in this study are made by assuming that unidirectional CNTs are randomly distributed in a polymer matrix. It is also assumed that each set of RVEs contains a constant fiber volume fraction and aspect ratio. Results show that randomness—the way in which fibers are distributed inside the matrix—has a significant effect on the thermal conductivity of CNT composites. Results of this study were compared using the analytical Xue and Nan model and good agreement was observed.


2021 ◽  
pp. 002199832110047
Author(s):  
Mahmoud Mohamed ◽  
Siddhartha Brahma ◽  
Haibin Ning ◽  
Selvum Pillay

Fiber prestressing during matrix curing can significantly improve the mechanical properties of fiber-reinforced polymer composites. One primary reason behind this improvement is the generated compressive residual stress within the cured matrix, which impedes cracks initiation and propagation. However, the prestressing force might diminish progressively with time due to the creep of the compressed matrix and the relaxation of the tensioned fiber. As a result, the initial compressive residual stress and the acquired improvement in mechanical properties are prone to decline over time. Therefore, it is necessary to evaluate the mechanical properties of the prestressed composites as time proceeds. This study monitors the change in the tensile and flexural properties of unidirectional prestressed glass fiber reinforced epoxy composites over a period of 12 months after manufacturing. The composites were prepared using three different fiber volume fractions 25%, 30%, and 40%. The results of mechanical testing showed that the prestressed composites acquired an initial increase up to 29% in the tensile properties and up to 32% in the flexural properties compared to the non-prestressed counterparts. Throughout the 12 months of study, the initial increase in both tensile and flexural strength showed a progressive reduction. The loss ratio of the initial increase was observed to be inversely proportional to the fiber volume fraction. For the prestressed composites fabricated with 25%, 30%, and 40% fiber volume fraction, the initial increase in tensile and flexural strength dropped by 29%, 25%, and 17%, respectively and by 34%, 26%, and 21%, respectively at the end of the study. Approximately 50% of the total loss took place over the first month after the manufacture, while after the sixth month, the reduction in mechanical properties became insignificant. Tensile modulus started to show a very slight reduction after the fourth/sixth month, while the flexural modulus reduction was observed from the beginning. Although the prestressed composites displayed time-dependent losses, their long-term mechanical properties still outperformed the non-prestressed counterparts.


2019 ◽  
Vol 253 ◽  
pp. 02004
Author(s):  
Wael Alnahhal ◽  
Omar Aljidda

This study investigates the effect of using different volume fractions of basalt macro fibers (BMF) on the flexural behavior of concrete beams made with 100% recycled concrete aggregates (RCA) experimentally. A total of 4 reinforced concrete (RC) beam specimens were flexural tested until failure. The parameter investigated included the BMF volume fraction (0%, 0.5%, 1%, and 1.5%). The testing results of the specimens were compared to control beam specimen made with no added fibers. The experimental results showed that adding BMF improves the flexural capacity of the tested beams.


Sign in / Sign up

Export Citation Format

Share Document