Clinical application of the high frequency area audiometer : Evaluation of the hearing loss in administration of cisplatin.

1997 ◽  
Vol 40 (5) ◽  
pp. 415-416
Author(s):  
MAKOTO HANAKURI
2018 ◽  
Vol 39 (04) ◽  
pp. 377-389 ◽  
Author(s):  
Susan Scollie ◽  
Danielle Glista

AbstractThis article provides a review of the current literature on the topic of frequency lowering hearing aid technology specific to the treatment of severe and profound levels of hearing impairment in child and adult listeners. Factors to consider when assessing listener candidacy for frequency lowering technology are discussed. These include factors related to audiometric assessment, the listener, the type of hearing aid technology, and the verification and validation procedures that can assist in determining candidacy for frequency lowering technology. An individualized candidacy assessment including the use of real-ear verification measures and carefully chosen validation tools are recommended for listeners requiring greater audibility of high-frequency sounds, when compared with amplification via conventional hearing aid technology.


1968 ◽  
Vol 11 (1) ◽  
pp. 204-218 ◽  
Author(s):  
Elizabeth Dodds ◽  
Earl Harford

Persons with a high frequency hearing loss are difficult cases for whom to find suitable amplification. We have experienced some success with this problem in our Hearing Clinics using a specially designed earmold with a hearing aid. Thirty-five cases with high frequency hearing losses were selected from our clinical files for analysis of test results using standard, vented, and open earpieces. A statistical analysis of test results revealed that PB scores in sound field, using an average conversational intensity level (70 dB SPL), were enhanced when utilizing any one of the three earmolds. This result was due undoubtedly to increased sensitivity provided by the hearing aid. Only the open earmold used with a CROS hearing aid resulted in a significant improvement in discrimination when compared with the group’s unaided PB score under earphones or when comparing inter-earmold scores. These findings suggest that the inclusion of the open earmold with a CROS aid in the audiologist’s armamentarium should increase his flexibility in selecting hearing aids for persons with a high frequency hearing loss.


Author(s):  
Wei Gong ◽  
Liangliang Zhao ◽  
Ling Li ◽  
Thais C. Morata ◽  
Wei Qiu ◽  
...  

A survey was administered to 385 noise-exposed workers from an auto parts factory and 1268 non-noise-exposed health department employees in China. Individual 8 h A-weighted equivalent sound levels (LAeq,8h), earplug personal attenuation ratings (PARs), and pure-tone audiometric tests were performed. The average LAeq,8h of noise-exposed workers was 87 dB (A) with a mean PAR of 7 dB. The prevalence of high-frequency hearing loss was 65% for noise-exposed workers and 33% for the non-noise-exposed employees. The use of earplugs had no observable effect on the prevalence of high-frequency hearing loss of the study participants (OR 0.964, 95% CI 0.925–1.005, p = 0.085). No significant relationship between the effectiveness offered by earplug use and high-frequency hearing thresholds at 3, 4, and 6 kHz was found (t = −1.54, p = 0.125). The mandatory requirement of earplug use without individualized training on how to wear HPDs correctly had no detectable effect on the prevention of hearing loss at the auto parts factory. The hearing conservation program at the surveyed factory was not effective. Periodic hearing tests, earplug fit testing, expanding the offer of different types of hearing protection, and employee education about the importance of protecting their hearing were recommended to the occupational health and safety program.


2005 ◽  
Vol 114 (3) ◽  
pp. 242-246
Author(s):  
Joni K. Doherty ◽  
Dennis R. Maceri

Proteus syndrome (PS) is a rare hamartomatous disorder characterized by mosaic overgrowth of multiple tissues that manifests early in life and is progressive. The presence of unilateral external auditory canal exostoses in a patient who is not a swimmer or surfer is suggestive of PS. However, hearing loss is not a typical feature. Here, we describe exostoses and ossicular discontinuity with conductive hearing loss in a patient with PS. The treatment consisted of canalplasty and ossicular chain reconstruction. A postoperative reduction was demonstrated in the patient's air-bone gap, from 21 dB to 13 dB for the pure tone average (four frequencies) and from 41 dB to 15 dB in the high-frequency range (6,000 to 8,000 Hz). Causes of ossicular discontinuity are discussed. Routine annual audiometric and otolaryngological evaluation should be considered in all patients with temporal bone inyolvement of PS.


2013 ◽  
Vol 127 (10) ◽  
pp. 952-956 ◽  
Author(s):  
A Goyal ◽  
P P Singh ◽  
A Vashishth

AbstractObjectives:This study aimed to: understand the effect that high intensity noise associated with drilling (during otological surgery) has on hearing in the contralateral ear; determine the nature of hearing loss, if any, by establishing whether it is temporary or persistent; and examine the association between hearing loss and various drill parameters.Methods:A prospective clinical study was carried out at a tertiary centre. Thirty patients with unilateral cholesteatoma and normal contralateral hearing were included. Patients were evaluated pre-operatively and for five days following surgery using high frequency pure tone audiometry, and low and high frequency transient evoked and distortion product otoacoustic emission testing.Results:The findings revealed statistically significant changes in distortion product otoacoustic emissions at high frequencies (p = 0.016), and in transient evoked otoacoustic emissions at both low and high frequencies (p = 0.035 and 0.021, respectively). There was a higher statistical association between otoacoustic emission changes and cutting burrs compared with diamond burrs.Conclusion:Drilling during mastoid surgery poses a threat to hearing in the contralateral ear due to noise and vibration conducted transcranially.


Sign in / Sign up

Export Citation Format

Share Document