A Novel Aqueous Ozone Treatment as a Spray Chill Intervention against Escherichia coli O157:H7 on Surfaces of Fresh Beef

2019 ◽  
Vol 82 (11) ◽  
pp. 1874-1878 ◽  
Author(s):  
NORASAK KALCHAYANAND ◽  
DREW WORLIE ◽  
TOMMY WHEELER

ABSTRACT This experiment determined the efficacy of using a novel aqueous ozone treatment as a spray chill intervention to reduce Escherichia coli O157:H7 on surfaces of fresh beef compared with traditional water spray chill. Cutaneous trunci muscles were obtained from a local beef cattle processing plant. Muscles were divided into sixteen 25-cm2 sections, and each section was individually inoculated with E. coli O157:H7 to the final concentration of approximately 105 CFU/cm2. Muscle sections were collected and tested before and after simulated spray chill treatments of water or the novel aqueous ozone solution. Enumeration of survivors of each treatment was compared with that of the untreated muscle sections. Water spray chill reduced (P ≤ 0.05) E. coli O157:H7 0.60 log, whereas the aqueous ozone spray chill reduction (P ≤ 0.05) was 1.46 log on surfaces of fresh beef. Aqueous ozone spray chill reduced (P ≤ 0.05) aerobic bacteria 0.99 log, but water spray chill did not significantly (P > 0.05) reduce aerobic bacteria on surfaces of fresh beef. The findings indicate that aqueous ozone can be used as a spray chill intervention to enhance the safety of beef.

2003 ◽  
Vol 66 (11) ◽  
pp. 2005-2009 ◽  
Author(s):  
XIANGWU NOU ◽  
MILDRED RIVERA-BETANCOURT ◽  
JOSEPH M. BOSILEVAC ◽  
TOMMY L. WHEELER ◽  
STEVEN D. SHACKELFORD ◽  
...  

The objective of this experiment was to test the hypothesis that cleaning cattle hides by removing hair and extraneous matter before hide removal would result in improved microbiological quality of carcasses in commercial beef processing plants. To test this hypothesis, we examined the effect of chemical dehairing of cattle hides on the prevalence of Escherichia coli O157:H7 and the levels of aerobic bacteria and Enterobacteriaceaeon carcasses. Samples from 240 control (conventionally processed) and 240 treated (chemically dehaired before hide removal) hides (immediately after stunning but before treatment) and preevisceration carcasses (immediately after hide removal) were obtained from four visits to a commercial beef processing plant. Total aerobic plate counts (APC) and Enterobacteriaceae counts (EBC) were not (P > 0.05) different between cattle designated for chemical dehairing (8.1 and 5.9 log CFU/100 cm2 for APC and EBC, respectively) and cattle designated for conventional processing (8.0 and 5.7 log CFU/100 cm2 for APC and EBC, respectively). However, E. coli O157:H7 hide prevalence was higher (P < 0.05) for the control group than for the treated group (67% versus 88%). In contrast to hides, the bacterial levels were lower (P < 0.05) on the treated (3.5 and 1.4 log CFU/100 cm2 for APC and EBC) than the control (5.5 and 3.2 log CFU/100 cm2 for APC and EBC) preevisceration carcasses. Prevalence of E. coli O157:H7 was lower (P > 0.05) on treated than on control preevisceration carcasses (1% versus 50%). These data indicate that chemical dehairing of cattle hides is an effective intervention to reduce the incidence of hide-to-carcass contamination with pathogens. The data also imply that any effective hide intervention process incorporated into beef processing procedures would significantly reduce carcass contamination by E. coli O157:H7.


2006 ◽  
Vol 69 (1) ◽  
pp. 6-11 ◽  
Author(s):  
L. SCOTT ◽  
P. McGEE ◽  
J. J. SHERIDAN ◽  
B. EARLEY ◽  
N. LEONARD

Escherichia coli O157:H7 is an important foodborne pathogen that can cause hemorrhagic colitis and hemolytic uremic syndrome. Cattle feces and fecally contaminated water are important in the transmission of this organism on the farm. In this study, the survival of E. coli O157:H7 in feces and water was compared following passage through the animal digestive tract or preparation in the laboratory. Feces were collected from steers before and after oral inoculation with a marked strain of E. coli O157:H7. Fecal samples collected before cattle inoculation were subsequently inoculated with the marked strain of E. coli O157:H7 prepared in the laboratory. Subsamples were taken from both animal and laboratory-inoculated feces to inoculate 5-liter volumes of water. E. coli O157:H7 in feces survived up to 97 days, and survival was not affected by the method used to prepare the inoculating strain. E. coli O157:H7 survived up to 109 days in water, and the bacteria collected from inoculated cattle were detected up to 10 weeks longer than the laboratory-prepared culture. This study suggests that pathogen survival in low-nutrient conditions may be enhanced by passage through the gastrointestinal tract.


2009 ◽  
Vol 72 (7) ◽  
pp. 1560-1568 ◽  
Author(s):  
HELGA J. DOERING ◽  
MARK A. HARRISON ◽  
RUTH A. MORROW ◽  
WILLIAM C. HURST ◽  
WILLIAM L. KERR

Lettuce and spinach inoculated with Escherichia coli O157:H7 were processed and handled in ways that might occur in commercial situations, including variations in holding times before and after product cooling, transportation conditions and temperatures, wash treatments, and product storage temperatures and times. Populations of background microflora and E. coli O157:H7 were enumerated after each step in the system. Data analysis was done to predict response variables with a combination of independent categorical variables. Field temperature, time before cooling, and wash treatment significantly affected E. coli O157:H7 populations on both products. The lowest populations of E. coli O157:H7 were encountered when precool time was minimal, lettuce was washed with chlorine, and storage temperature was 4°C. For lettuce, field and transportation temperature were not important once the storage period started, whereas after 2 days E. coli O157:H7 populations on packaged baby spinach were not affected by field temperature. On chopped iceberg lettuce and whole leaf spinach that was packaged and stored at 4°C, E. coli O157:H7 contamination could still be detected after typical handling practices, although populations decreased from initial levels in many cases by at least 1.5 log units. In abusive cases, where populations increased, the product quality quickly deteriorated. Although E. coli O157:H7 levels decreased on products handled and stored under recommended conditions, survivors persisted. This study highlights practices that may or may not affect the populations of E. coli O157:H7 on the final product.


2007 ◽  
Vol 70 (1) ◽  
pp. 17-21 ◽  
Author(s):  
A. L. REICKS ◽  
M. M. BRASHEARS ◽  
K. D. ADAMS ◽  
J. C. BROOKS ◽  
J. R. BLANTON ◽  
...  

Prevalences of Escherichia coli O157:H7, Salmonella, and total aerobic microorganisms were determined on the hides of beef feedlot cattle before and after transport from the feedyard to the harvest facility in clean and dirty trailers. Swab samples were taken from the midline and withers of 40 animals on each of 8 days before and after shipping. After samples were collected, animals were loaded in groups of 10 on upper and lower levels of clean and dirty trailers. Animals were unloaded at the harvest facility and kept in treatment groups for sample collection after exsanguination. Salmonella was found more often on hide swabs collected from the midline than on than samples collected from the withers from animals transported in both clean and dirty trailers. Salmonella was found on significantly more hide swabs collected at harvest from both sampling locations than on those collected at the feedyard, with no differences attributed to the type of trailer. At the feedyard, clean trucks had a lower percentage of Salmonella-positive samples than did dirty trucks before animals were loaded. However, after transport, both clean and dirty trucks had a similar prevalence of Salmonella. There were no differences in Salmonella prevalence on hides collected from animals transported on the top and bottom levels of clean and dirty trucks. E. coli O157:H7 was detected on less than 2% of the samples; therefore, no practical conclusions about prevalence could be drawn. Hides sampled at harvest had higher concentrations of aerobic microorganisms than did hides sampled at the feedyard, and concentrations were higher on the midline than on the withers. Although the prevalences of Salmonella and total aerobic microorganisms increased on hides after transport from the feedyard to the plant, this increase was not related to the cleanliness of the trailers or the location of the cattle in the trailers.


2004 ◽  
Vol 67 (11) ◽  
pp. 2381-2386 ◽  
Author(s):  
ROBERT C. WILLIAMS ◽  
SUSAN S. SUMNER ◽  
DAVID A. GOLDEN

Inactivation of Escherichia coli O157:H7 and Salmonella in apple cider and orange juice treated with ozone was evaluated. A five-strain mixture of E. coli O157:H7 or a five-serovar mixture of Salmonella was inoculated (7 log CFU/ml) into apple cider and orange juice. Ozone (0.9 g/h) was pumped into juices maintained at 4°C, ambient temperature (approximately 20°C), and 50°C for up to 240 min, depending on organism, juice, and treatment temperature. Samples were withdrawn, diluted in 0.1% peptone water, and surface plated onto recovery media. Recovery of E. coli O157:H7 was compared on tryptic soy agar (TSA), sorbitol MacConkey agar, hemorrhagic coli agar, and modified eosin methylene blue agar; recovery of Salmonella was compared on TSA, bismuth sulfite agar, and xylose lysine tergitol 4 (XLT4) agar. After treatment at 50°C, E. coli O157:H7 populations were undetectable (limit of 1.0 log CFU/ml; a minimum 6.0-log CFU/ml reduction) after 45 min in apple cider and 75 min in orange juice. At 50°C, Salmonella was reduced by 4.8 log CFU/ml (apple cider) and was undetectable in orange juice after 15 min. E. coli O157:H7 at 4°C was reduced by 4.8 log CFU/ml in apple cider and by 5.4 log CFU/ml in orange juice. Salmonella was reduced by 4.5 log CFU/ml (apple cider) and 4.2 log CFU/ml (orange juice) at 4°C. Treatment at ambient temperature resulted in population reductions of less than 5.0 log CFU/ml. Recovery of E. coli O157:H7 and Salmonella on selective media was substantially lower than recovery on TSA, indicating development of sublethal injury. Ozone treatment of apple cider and orange juice at 4°C or in combination with mild heating (50°C) may provide an alternative to thermal pasteurization for reduction of E. coli O157:H7 and Salmonella in apple cider and orange juice.


2007 ◽  
Vol 70 (5) ◽  
pp. 1093-1098 ◽  
Author(s):  
KATHERINE L. BIALKA ◽  
ALI DEMIRCI

Each year in the United States, there are approximately 76 million foodborne illnesses, and fresh produce is the second most common vehicle for such illnesses. Before going to market, small fruits are not washed or treated in any manner to extend their shelf life. Washing alone is not a viable option, and the use of novel technologies should be investigated. One such technology is ozone treatment, which has been used with drinking water since the late 19th century. The efficacy of gaseous ozone for killing pathogens on strawberries and raspberries, which were used as a model for small fruits, was investigated in this study. Strawberries and raspberries were artificially contaminated with five strains of Escherichia coli O157:H7 and Salmonella enterica. Fruits were treated with four ozone treatments: (i) continuous ozone flow (5%, wt/wt) for 2, 4, 8, 16, 32, and 64 min; (ii) pressurized ozone (83 kPa) for 2, 4, 8, 16, 32, and 64 min; (iii) continuous ozone (64 min) followed by pressurized ozone (64 min); and (iv) vacuum followed by 64 min of pressurized ozone. Maximum reductions for both strawberries and raspberries were achieved with the third treatment scenario. On strawberries, 2.60- and 2.96-log reductions were achieved for Salmonella and E. coli O157:H7, respectively. For raspberries, 3.55- and 3.75-log reductions were achieved for Salmonella and E. coli O157:H7, respectively. These results indicate that gaseous ozone should be a useful treatment for decontamination of small fruits.


2003 ◽  
Vol 66 (5) ◽  
pp. 775-779 ◽  
Author(s):  
A. CASTILLO ◽  
K. S. MCKENZIE ◽  
L. M. LUCIA ◽  
G. R. ACUFF

The effectiveness of an aqueous ozone treatment in reducing Escherichia coli O157:H7 and Salmonella serotype Typhimurium on hot carcass surfaces was determined with the use of a model carcass spray cabinet. Carcass surface regions were removed from carcasses and inoculated with feces containing 106 to 107 CFU each of E. coli O157:H7 and Salmonella Typhimurium per g and were then exposed to a water wash or to a water wash followed by a sanitizing ozone treatment. Water washes were applied at 28°C beginning at a pressure of 10 lb/in2 and gradually increasing to 400 lb/in2. Ozone treatment was carried out by spraying surfaces with an aqueous ozone solution (80 lb/in2 at 28°C) containing 95 mg of ozone per liter. Pathogen reductions achieved with ozone treatment were not significantly different from those achieved with a water wash alone. In addition, ozone treatment did not reduce E. coli O157:H7 or Salmonella Typhimurium contamination that was spread over the carcass surface as a result of the water wash. Under the conditions of this study, the aqueous ozone treatment applied resulted in no significant improvement over a water wash in reducing pathogens on beef carcass surfaces.


2010 ◽  
Vol 73 (7) ◽  
pp. 1225-1230 ◽  
Author(s):  
HOIKYUNG KIM ◽  
HAEYOUNG KIM ◽  
JIHYUN BANG ◽  
LARRY R. BEUCHAT ◽  
JEE-HOON RYU

Studies were done to determine whether calcium hypochlorite (Ca(OCl)2) and chlorine dioxide (ClO2) treatment followed by drying had a synergistic killing effect on microorganisms on radish seeds intended for sprout production. Uninoculated radish seeds and seeds inoculated with Escherichia coli O157:H7 were treated with water, Ca(OCl)2 (free chlorine concentrations of 50 or 200 μg/ml), or ClO2 (50 or 200 μg/ml) for 5 min and subsequently dried at 25°C for up to 24 h. Populations of total aerobic bacteria (TAB), molds and yeasts (MY), and E. coli O157:H7 on the seeds treated with Ca(OCl)2 were not significantly different (P = 0.05) than populations on seeds treated with ClO2 at the same concentrations. However, populations of microorganisms on seeds treated with ClO2 decreased more rapidly during drying. Treatment with ClO2 (200 μg/ml) followed by drying caused reductions in TAB, MY, and E. coli O157:H7 of 3.1, 2.0, and 3.8 log CFU/g, respectively. When seeds were treated with water, Ca(OCl)2 (50 or 200 μg/ml), and ClO2 (50 μg/ml) and subsequently dried, reductions in TAB, MY, and E. coli O157:H7 were 0.2 to 2.0, 0.4 to 2.0, and 1.4 to 2.2 log CFU/g, respectively. Results indicate that inactivation of E. coli O157:H7 on radish seeds is greater after treatment with ClO2 followed by drying than after treatment with Ca(OCl)2 followed by drying, thus providing a synergistic treatment combination for reducing the safety risk associated with sprouts produced from these seeds.


2007 ◽  
Vol 70 (5) ◽  
pp. 1076-1079 ◽  
Author(s):  
TERRANCE M. ARTHUR ◽  
JOSEPH M. BOSILEVAC ◽  
DAYNA M. BRICHTA-HARHAY ◽  
NORASAK KALCHAYANAND ◽  
STEVEN D. SHACKELFORD ◽  
...  

Harborage of Escherichia coli O157:H7 and Salmonella on animal hides at slaughter is the main source of beef carcass contamination during processing. Given this finding, interventions have been designed and implemented to target the hides of cattle following entry into beef processing plants. Previous interventions targeting hides have not been suitable for all beef processing plants because of cost and space restrictions. In this study, a hide wash cabinet was evaluated to determine whether it was more amenable to widespread use in the beef processing industry, especially for small and medium-size plants. Overall, 101 (35.1%) of 288 beef cattle hides sampled before entry into the hide wash cabinet harbored E. coli O157:H7 at or above the limit of detection (40 CFU/100 cm2). After passage through the hide wash cabinet, only 38 (13.2%) of 288 hides had E. coli O157:H7 levels ≥40 CFU/100 cm2. Before the hide wash cabinet, 50 (17%) of 288 hides harbored E. coli O157:H7 at levels above 100 CFU/100 cm2, with one sample as high as 20,000 CFU/100 cm2. In contrast, only 14 (5%) of 288 hides had E. coli O157:H7 levels above 100 CFU/100 cm2 after hide washing, with the highest being 2,000 CFU/100 cm2. These same trends also were found for Salmonella before and after hide washing. These results indicate that the hide wash cabinet described in this study was effective and should provide small and medium-size processing plants with an affordable hide wash intervention strategy.


2008 ◽  
Vol 71 (9) ◽  
pp. 1752-1760 ◽  
Author(s):  
TERRANCE M. ARTHUR ◽  
JOSEPH M. BOSILEVAC ◽  
DAYNA M. BRICHTA-HARHAY ◽  
NORASAK KALCHAYANAND ◽  
DAVID A. KING ◽  
...  

Transportation from the feedlot and lairage at the processing plant have been identified as potential sources of Escherichia coli O157:H7 and Salmonella hide contamination. The objective of this study was to perform a comprehensive tracking analysis of E. coli O157:H7 and Salmonella associated with beef cattle from the feedlot through processing. Cattle (n = 581) were sampled in a feedlot, then transported in multiple lots to three commercial, fed beef processing plants in the United States, where they were sampled again. Samples were collected from the tractor trailers prior to loading cattle and from the lairage environment spaces prior to entry of the study cattle. Pathogen prevalence on cattle hides increased on every lot of cattle between exiting the feedlot and beginning processing. Prior to loading cattle, E. coli O157:H7 was found in 9 (64%) of 14 tractor trailers. E. coli O157:H7 was detected in over 60% of the samples from each lairage environment area, while Salmonella was detected in over 70% of the samples from each lairage environment area. E. coli O157:H7 and Salmonella isolates (n 3,645) were analyzed using pulsed-field gel electrophoresis. The results of the pulsed-field gel electrophoresis tracking indicate that the transfer of bacteria onto cattle hides that occurs in the lairage environments of U.S beef processing plants accounts for a larger proportion of the hide and carcass contamination than does the initial bacterial population found on the cattle exiting the feedlot. Finally, the results of this study indicate that hide wash cabinets are effective in removing contamination derived from the lairage environment.


Sign in / Sign up

Export Citation Format

Share Document