scholarly journals Direct Punching Shear Strength Model for Interior Slab-Column Connections and Column Footings with Shear Reinforcement

2011 ◽  
Vol 23 (2) ◽  
pp. 159-168 ◽  
Author(s):  
Kyoung-Kyu Choi ◽  
Sug-Hwan Kim ◽  
Dong-Hoon Kim ◽  
Hong-Gun Park
2021 ◽  
Vol 11 (6) ◽  
pp. 2736
Author(s):  
Min Sook Kim ◽  
Young Hak Lee

In this study, the structural behavior of reinforced concrete flat plates shear reinforced with vertical grids made of a glass fiber reinforced polymer (GFRP) was experimentally evaluated. To examine the shear strength, experiments were performed on nine concrete slabs with different amounts and spacings of shear reinforcement. The test results indicated that the shear strength increased as the amount of shear reinforcement increased and as the spacing of the shear reinforcement decreased. The GFRP shear reinforcement changed the cracks and failure mode of the specimens from a brittle punching to flexure one. In addition, the experimental results are compared with a shear strength equation provided by different concrete design codes. This comparison demonstrates that all of the equations underestimate the shear strength of reinforced concrete flat plates shear reinforced with GFRP vertical grids. The shear strength of the equation by BS 8110 is able to calculate the punching shear strength reasonably for a concrete flat plate shear reinforced with GFRP vertical grids.


2002 ◽  
Vol 29 (4) ◽  
pp. 602-611 ◽  
Author(s):  
Ehab F El-Salakawy ◽  
Maria Anna Polak ◽  
Khaled A Soudki

The paper presents work on punching shear rehabilitation and strengthening of existing slab–column connections. Four full-scale specimens representing slab–column edge connections were built and tested to failure. Three slabs were then repaired and strengthened and tested again. In the originally tested slabs, which were chosen for repair, one slab had an opening in front of the column and contained shear reinforcement, one slab had an opening and no shear reinforcement, and one had no opening and no reinforcement. The dimensions of the slabs were 1540 × 1020 × 120 mm with square columns (250 × 250 mm). The openings in the specimens were square (150 × 150 mm) with the sides parallel to the sides of the column. The slabs were made using normal weight concrete (28-day average compressive strength of 32 MPa) and reinforced with a reinforcement ratio of 0.75%. The slabs were repaired by replacing old-damaged concrete with new concrete of the same properties. Strengthening was carried out using shear studs for the two slabs, which originally did not have shear reinforcement. The rehabilitation increased the punching shear strength (by 26–41%) and the ductility of the connections. All repaired specimens failed in flexure.Key words: concrete slabs, punching shear, rehabilitation, edge connections, openings, studs, repair.


2021 ◽  
Vol 147 (7) ◽  
Author(s):  
Marília G. Marques ◽  
Elyson A. P. Liberati ◽  
Ronaldo B. Gomes ◽  
Alessandra L. Carvalho ◽  
Leandro M. Trautwein

2014 ◽  
Vol 627 ◽  
pp. 245-248
Author(s):  
Hyun Ki Choi

The punching shear on the flat plate slab-column connection can bring about the reason of the brittle punching shear failure which may result of collapsing the whole structure. From the development of residential flat plate system, the shear reinforcement is developed for preventing the punching shear. This study proposed 3 reinforcements that are increased to bond capacity using lateral bar, the structure test is performed. As performed test result, because slabs not keep enough bond length, slab is failed before shear reinforcement's yield strength duo to anchorage of slip. According to result, FEM analyzed an effect of slab thickness and concrete compressive. The study suggests shear strength formula that possible a positive shear reinforcement in slab-column connection.


1996 ◽  
Vol 23 (5) ◽  
pp. 998-1011 ◽  
Author(s):  
Alaa G. Sherif ◽  
Walter H. Dilger

The purpose of this paper is to demonstrate that the shear design of slabs according to the relevant Canadian CSA A23.3-94 (and U.S. ACI 318-95) design codes can be unsafe under certain conditions, and to propose improved design equations, some of which should be considered immediately for implementation in the Canadian CSA code. The paper deals with interior slab–column connections, with and without shear reinforcement, subjected to shear force alone or to a combination of shear force and unbalanced bending moment. Some comparisons with the British code BS 8110-85 and the CEB –FIP model code 1990 are also made. Tests reported in the literature and some experiments by the authors provide the basis for this study. Key words: flat concrete plates, slab–column connections, shear strength, punching shear, shear reinforcement, moment transfer.


2017 ◽  
Vol 2017 ◽  
pp. 1-10 ◽  
Author(s):  
Min Sook Kim ◽  
Young Hak Lee

The shear performance of concrete flat plates with glass fiber-reinforced polymer (GFRP) plate shear reinforcement was investigated through punching shear tests. Each GFRP plate was embedded in the concrete and included openings to permit the flow of concrete during fabrication. Punching shear tests were conducted on a total of 8 specimens, and the resulting crack and fracture formations, strains, and load-displacement curves were analyzed and compared. The experimental variables considered were the types of shear reinforcement, including steel stirrups or GFRP plates, and the shear reinforcement spacing. The experimental results show that the GFRP shear reinforcement effectively increased the shear strengths of flat plates. Furthermore, the applicability of two formulas was investigated: a modified version of a shear strength formula from ACI 318-14 and the ACI 318-14 fracture prediction formula.


Sign in / Sign up

Export Citation Format

Share Document