scholarly journals Effect of Power Pump and Nozzle Diameter Microbubble Generator to Increase Oxygen Concentration in Aquaculture

Author(s):  
Imam Taukhid ◽  
Dody D. Trijuno ◽  
Muhammad Y. Karim ◽  
Rachman Syah ◽  
Makmur Makmur
2014 ◽  
Vol 960-961 ◽  
pp. 528-533
Author(s):  
Dong Jun Kim ◽  
Hui Wei Du ◽  
Kyuho Kim ◽  
Lu Peng ◽  
Heicheon Yang

The objective of this study is to investigate the air entrainment and oxygen transfer characteristics of central-driven ejector with various ejector design parameters. The ejector design parameters are primary nozzle diameter, mixing tube length and diffuser angle. The entrainment ratio decreased with the primary nozzle diameter and diffuser angle, while the ratio increased with the mixing tube length. The trend of dissolved oxygen concentration with the diffuser angle and mixing tube length is equal to the result of entrainment ratio, however, the trend with the primary nozzle diameter is different to the result of entrainment ratio.


2016 ◽  
Vol 15 (2) ◽  
pp. 46
Author(s):  
L. S. Baldani ◽  
P. S. B. Zdanski

This work presents an experimental and numerical study addressing the effects of air entrainment for self aspiring burners. Within this framework, the work focus on the analysis of four different burners tested with four different nozzles, resulting in a total of sixteen different configurations. The gas used for the tests was methane. Each nozzle diameter provided a different flow rate, which also resulted in a different entrainment, therefore a different oxygen concentration on the ports area, which was measured using an oxygen sensor. The level of oxygen decreased with the increase of the flow rate of the gas, and had a linear behavior with the nozzle diameter. The finite volume method with the realizable k-ε model was then applied to numerically investigate this phenomenon using the commercial software STARCCM+. The results shows that for the sixteen points tested the worst correlation had a relative error of 2.95%, while for the best one was of 0.04%.


Author(s):  
H. Takaoka ◽  
M. Tomita ◽  
T. Hayashi

High resolution transmission electron microscopy (HRTEM) is the effective technique for characterization of detailed structure of semiconductor materials. Oxygen is one of the important impurities in semiconductors. Detailed structure of highly oxygen doped silicon has not clearly investigated yet. This report describes detailed structure of highly oxygen doped silicon observed by HRTEM. Both samples prepared by Molecular beam epitaxy (MBE) and ion implantation were observed to investigate effects of oxygen concentration and doping methods to the crystal structure.The observed oxygen doped samples were prepared by MBE method in oxygen environment on (111) substrates. Oxygen concentration was about 1021 atoms/cm3. Another sample was silicon of (100) orientation implanted with oxygen ions at an energy of 180 keV. Oxygen concentration of this sample was about 1020 atoms/cm3 Cross-sectional specimens of (011) orientation were prepared by argon ion thinning and were observed by TEM at an accelerating voltage of 400 kV.


2017 ◽  
Vol 5 (3) ◽  
pp. 259
Author(s):  
Shireen H. Ramadhan ◽  
Shamil K. Talal ◽  
Wasfiya A. Moner

Tobacco smoke is enormously harmful to human health, there’s no safe way to smoke. The primary objective of this study is to analyze the role of tobacco smoke compounds and their ability to damage the cardiovascular system and, in particular, to interfere with blood pressure (Brachial and radial pressure), heart rate and partly on the percentage blood Oxygen saturation. A new device has been manufactured which is unique for measuring the level of smoke, to obtained privies readings, the device had fixed to the first reference level آ and starting up from it. The effect of smoking has been studied on (26) male passive (26) active smoker volunteer, (14) female passive and (14) female active smoker participants. The results has been showed that the blood pressure and heart rate has been increased with increasing the number of cigarettes in both genders for passive and active smokers. However, this effect for male was more pronounced comparing with females for passive and active smokers. In the case of oxygen saturation concentration percentage, for males the change of oxygen concentration percentage was not stable. In other words, it was fluctuated with the number of cigarettes. But for females the oxygen concentration was decreased but not too much. This means that this effect was not pronounced. this study found آ that the most pronounced effect has been shown by male’s comparison to females for both passive and active smokers. As well as in nonsmoker’s males, the relation between heart rate and smoke level is inversely proportional. While in male and female smokers and female nonsmokers the relation is proportional. In all cases the relation between the smoke level and time of smoking is inversely proportional. Finally males& females are affected differently by tobacco use; the sensitivities to smoke for males are higher than in females for passive and active smokers in both brachial and radial blood pressure measurement.


Sign in / Sign up

Export Citation Format

Share Document