scholarly journals Comparison of PSF and Non PSF BLOB based reconstructed image in Time-of-Flight PET/CT

Author(s):  
Manish Kumar Vishwakarma ◽  

Hybrid PET/CT imaging with the use of 18F FDG is a widely used imaging technique with major indications in oncology for staging, re-staging and monitoring response to therapy. There is a major issue of partial volume effect in PET images which affects image quality as well as quantitative accuracy in small lesions. Multiple attempts have been made to resolve these issues. The aim of our study was to look into impact of Point‐spread-function (PSF) on reconstructed attenuation corrected (AC) images of PET/CT and to find out best combination of the number of PSF iterations with regularization level while applying PSF.

2017 ◽  
Vol 38 (6) ◽  
pp. 471-479 ◽  
Author(s):  
Nicholas J. Vennart ◽  
Nicholas Bird ◽  
John Buscombe ◽  
Heok K. Cheow ◽  
Ewa Nowosinska ◽  
...  

2018 ◽  
Vol 63 (23) ◽  
pp. 235010 ◽  
Author(s):  
Alice Ferretti ◽  
Sotirios Chondrogiannis ◽  
Lucia Rampin ◽  
Elena Bellan ◽  
Maria Cristina Marzola ◽  
...  

2010 ◽  
Vol 24 (8) ◽  
pp. 585-591 ◽  
Author(s):  
Yuichi Sakaguchi ◽  
Noriko Mizoguchi ◽  
Tatsuya Mitsumoto ◽  
Katsuhiko Mitsumoto ◽  
Kazuhiko Himuro ◽  
...  

2021 ◽  
Author(s):  
Kosuke Yamashita ◽  
Noriaki Miyaji ◽  
Kazuki Motegi ◽  
Takashi Terauchi ◽  
Shigeki Ito

Abstract BackgroundSomatostatin receptor scintigraphy (SRS) using 111In-pentetreotide has no established quantification method. The purpose of this study was to develop a new quantitative method to correct the partial volume effect (PVE) for individual energy peaks in 111In-pentetreotide single-photon emission computed tomography (SPECT). MethodsPhantom experiments were performed to construct a new quantitative method. In the phantom experiments, a NEMA IEC body phantom was used. Acquisition was performed using two energy peaks (171 keV and 245 keV) on the SPECT/CT system. In the SPECT images of each energy peak, the region of interest was set at each hot sphere and lung insert, and the recovery coefficient (RC) was calculated to understand the PVE. A new quantitative index, the indium uptake index (IUI), was calculated using the RC to correct the PVE. The quantitative accuracy of the IUI in the hot sphere was confirmed. Case studies were performed to clarify the quantitative accuracy. In a case study, the relationship between the IUI and the Krenning score, which is used as a visual assessment, was evaluated for each lesion. ResultsThe obtained RCs showed that the energy peak at 171 keV was faster in recovering the effect of PVE than that at 245 keV. The IUI in the 17 mm diameter hot sphere was overestimated by 3.1% at 171 keV and underestimated by 0.5% at 245 keV compared to the actual IUI. In case studies, the relationship between IUI and Krenning score was rs = 0.805 (p < 0.005) at sum, rs = 0.77 (p < 0.005) at 171 keV, and rs = 0.84 (p < 0.005) at 245 keV.Conclusion We have developed a new quantification method for 111In-pentetreotide SPECT/CT using RC-based PVE correction for an individual energy peak of 171 keV. The quantitative accuracy of this method was high even for accumulations of less than 20 mm, and it showed a good relationship with the Krenning score; therefore, the clinical usefulness of IUI was demonstrated.


2013 ◽  
Vol 38 (6) ◽  
pp. 407-412 ◽  
Author(s):  
Go Akamatsu ◽  
Katsuhiko Mitsumoto ◽  
Kaori Ishikawa ◽  
Takafumi Taniguchi ◽  
Nobuyoshi Ohya ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document