scholarly journals Effect of Self-etch Primer-adhesive and Conventional Adhesive Systems on the Shear Bond Strength and Bond Failure of Orthodontic Brackets: A Comparative Study

2015 ◽  
Vol 16 (2) ◽  
pp. 130-134 ◽  
Author(s):  
N Sanjay ◽  
RNG Rajesh ◽  
KS Girish ◽  
Malthesh B Savakkanavar ◽  
S Sreedhara ◽  
...  

ABSTRACT Background Prompt-L-Pop is a sixth generation bonding system contains methacrylated phosphoric acid esters that combine an acidic component for etching the enamel and a primer, is an all-in-one adhesive. This study was undertaken to compare the bonding strength of brackets to enamel with traditional bonding technique and the new Prompt-L-Pop system using the same composite resin. Materials and methods In this in vitro experimental study, 60 human premolar teeth extracted for orthodontic treatment were collected. The samples were randomly divided into three groups comprising of 20 teeth in each group. Shear bond strength and ARI scores for the specimens were measured. Comparison was done using one way ANOVA and Chi-square test. Results Fourth generation bonding adhesive system depicted similar bond strength to fifth generation bonding adhesive system. Both fourth and fifth generation exhibited higher shear bond strength as compared to sixth generation bonding adhesive system. Conclusion Fourth and fifth generation exhibited higher shear bond strength as compared to sixth generation bonding adhesive system but the sixth generation has clinically acceptable shear bond strength. Also, it was found that sixth generation leaves less residual adhesive on the tooth after bracket removal. How to cite this article Sreedhara S, Savakkanavar MB, Rajesh RNG, Ankireddy RKR, Sanjay N, Girish KS. Effect of Self-etch Primer-adhesive and Conventional Adhesive Systems on the Shear Bond Strength and Bond Failure of Orthodontic Brackets: A Comparative Study. J Contemp Dent Pract 2015;16(2):130-134.

2008 ◽  
Vol 78 (3) ◽  
pp. 531-536 ◽  
Author(s):  
Mona A. Montasser ◽  
James L. Drummond ◽  
Carla A. Evans

Abstract Objective: To compare rebonding of orthodontic brackets based on the hypothesis that no difference would be found between the adhesive systems with respect to shear bond strength, mode of failure, and clinical failure rates. Materials and Methods: The three adhesive systems included two self-etch primers (Transbond and M-Bond) and a conventional phosphoric acid etch (Rely-a-Bond). The sample size was 20 premolars for each adhesive system. The shear bond strength was tested 24 hours after bracket bonding with the bonding/debonding procedures repeated two times after the first debonding. Bond strength, adhesive remnant index (ARI), and failure sites were evaluated for each debonding. Statistical analysis consisted of a two-way analysis of variance (ANOVA) followed by Scheffè analysis. The clinical portion evaluated 15 patients over a 12-month period. Results: The mean shear bond strengths after the first, second, and third debondings for Rely-a-Bond were 8.4 ± 1.8, 10.3 ± 2.4, and 14.1 ± 3.3 MPa, respectively; for Transbond 11.1 ± 4.6, 13.6 ± 4.5, and 12.9 ± 4.4 MPa, respectively; and for M-Bond 8.7 ± 2.7, 10.4 ± 2.4, and 12.4 ± 3.4 MPa, respectively. After the three debondings the mean shear bond strength increased significantly from the first to the third debonding for Rely-a-Bond and M-bond (P ≤ .001), but did not change for Transbond (P = .199). Conclusions: The original hypothesis is not rejected. The two self-etching primers showing higher or comparable bond strength to the conventional phosphoric etch with less adhesive remnant on the enamel surface after the first debonding. With repeated bonding/debonding, the differences in the bond strength, ARI, and failure site were not significantly different. There was no difference in the clinical performance of the three adhesive systems (P = .667).


2009 ◽  
Vol 79 (3) ◽  
pp. 564-570 ◽  
Author(s):  
Toshiya Endo ◽  
Rieko Ozoe ◽  
Koichi Shinkai ◽  
Makiko Aoyagi ◽  
Hiroomi Kurokawa ◽  
...  

Abstract Objective: To ascertain the effects of repeated bonding on the shear bond strength of orthodontic brackets bonded with a fluoride-releasing and -recharging adhesive system with a self-etching primer in comparison with two other types of adhesive system. Materials and Methods: A total of 48 premolars were collected and divided equally into three groups of 16. Each group was assigned one of three adhesive systems: Transbond XT, Transbond Plus, or a fluoride-releasing and -recharging adhesive system, Beauty Ortho Bond. Shear bond strength was measured 24 hours after bracket bonding, with the bonding/debonding procedures repeated twice after the first debonding. A universal testing machine was used to determine shear bond strengths, and bracket/adhesive failure modes were evaluated with the adhesive remnant index after each debonding. Results: At every debonding sequence, all of these three adhesive systems had a shear bond strength of 6 MPa, which is a minimum requirement for clinical use. Transbond XT and Transbond Plus had significantly higher mean shear bond strengths than did Beauty Ortho Bond at each debonding. No significant differences in mean bond strength were observed between the three debondings in each adhesive system. Bond failure at the enamel/adhesive interface occurred more frequently in Beauty Ortho Bond than in Transbond XT or Transbond Plus. Conclusions: The fluoride-releasing and -recharging adhesive system with the self-etching primer (Beauty Ortho Bond) had clinically sufficient shear bond strength in repeated bracket bonding; this finding can help orthodontists to decrease the risk of damage to enamel at debonding.


2014 ◽  
Vol 13 (1) ◽  
pp. 7
Author(s):  
Dewi Puspitasari ◽  
Andi Soufyan ◽  
Ellyza Herda

Composite resin is a widely used aesthetic restoration. The restoration can fail due to secondary caries. Chlorhexidinegluconate 2% is used as a cavity disinfectant to eliminate microorganisms on the prepared cavity and to prevent thesecondary caries. The purpose of this study was to analyze the effect of chlorhexidine gluconate 2% to the bondstrength of composite resin with self etch system adhesive on dentine. Sixteen specimens of buccal dentine of premolarscrown are divided into 2 different groups. Group I: Clearfil SE Bond self-etch primer was applied for 20 seconds,Clearfil SE Bond bonding was applied for 5 seconds and polymerized for 10 seconds. Composite resin was constructedincrementally and polymerized for 20 seconds. Group II: prior to self etch primer application as in group I,chlorhexidine gluconate 2% was applied for 15 seconds. Shear bond strength was tested using Testing machine andanalyzed with unpaired T test. The highest shear bond strength was obtained by applying chlorhexidine gluconate 2%.The study concludes that chlorhexidine gluconate 2% application to dentine did not affect significantly to the bondstrength composite resin using self etch adhesive systems.


2015 ◽  
Vol 16 (5) ◽  
pp. 335-339 ◽  
Author(s):  
Zeeshan H Ahmad ◽  
Sukumaran Anil ◽  
Alaa El Araby ◽  
Mohammad D Al Amri

ABSTRACT Objective To evaluate the influence of Expasyl® gingival retraction paste on the shear bond strength of self-etch and total-etch adhesive systems. Materials and methods Twenty-four specimens of extracted, caries-free, sound human molars were used in this study. The molars were then cut vertically into halves through the buccal and lingual cusps. Forty-eight specimens were divided into four groups (total-etch, total-etch with Expasyl application, self-etch, self-etch with Expasyl application) and the shear bond strength was tested. Results Expasyl significantly reduced the shear bond strength of the self-etch and total-etch adhesive systems. The self-etch system showed relatively lower performance compared with the total-etch adhesive system. The shear bond strength values of the total-etch adhesive without Expasyl showed the highest bond strength (21.48 ± 2.89), while the self-etching group adhesive treated with Expasyl showed the lowest shear bond strength value (14.89 ± 1.81). Conclusion From the observations of this in vitro study, it can be concluded that the use of Expasyl® gingival retraction system can negatively affect bond strength of adhesives. The total-etch system showed better compatibility to the Expasyl gingival retraction system than the self-etch. How to cite this article Al Baker AMA, El Araby A, Al Amri MD, Sukumaran A. The Impact of Expasyl® Gingival Retraction Paste on the Bond Strength of Self-etch and Total-etch Systems. J Contemp Dent Pract 2015;16(5):335-339.


2021 ◽  
Vol 24 (2) ◽  
Author(s):  
Fateme Vasei ◽  
Farahnaz Sharafeddin

Objective: To assess the shear bond strength (SBS) of resin composite to deep dentin, using 1 and 2.5% chitosan pretreatment as well as different adhesive systems. Material and Methods: 80 human maxillary molars were randomly divided to eight groups according to the type of adhesive system and dentin pretreatment (n = 10): I) two-step self-etch system (Clearfil SE bond); II) two-step etch-andrinse system (Adper single bond 2); III) 2.5% chitosan + Clearfil SE bond; IV) 2.5% chitosan +etch + Adper single bond 2; V) etch + 2.5% chitosan + Adper single bond 2; VI) 1% chitosan + Clearfil SE bond; VII) 1% chitosan + etch + Adper single bond 2; VIII) etch + 1% chitosan + Adper single bond 2 (chitosan solution (w/v): 2.5 g and 1 g of chitosan (Sigma Aldrich, USA) was dissolved in 100 ml of 1% acetic acid). Plastic molds were positioned on dentin and filled with composite (Z350, 3M ESPE, USA). SBS (MPa) was tested using a universal testing machine. ANOVA tests, Tukey’s test, and independent t test were used to analyze data (p < 0.05). Results: The highest SBS value among self-etch groups was observed with 1% chitosan (p = 0.001). In the etch-and-rinse group, the SBS of 1% chitosan was significantly lower than the other groups. Chitosan treatment following acid etching led to higher SBS in comparison to when chitosan was applied before etching, with the significant difference in 1% concentration (p = 0.030). A predominance of mix fractures was observed in dentin. Conclusion: Improved dentin bond strength can be achieved through immediate dentin pretreatment with 1% chitosan in self-etch adhesive systems. Chitosan Pretreatment may not be advantageous for etch-and-rinse adhesive systems. Keywords Adhesive system; Chitosan; Deep dentin; Shear strength.


2010 ◽  
Vol 04 (04) ◽  
pp. 367-373 ◽  
Author(s):  
Sevi Burcak Cehreli ◽  
Asli Guzey ◽  
Neslihan Arhun ◽  
Alev Cetinsahin ◽  
Bahtiyar Unver

Objectives: The aim of this in vitro study is to determine (1) shear bond strength (SBS) of brackets bonded with self-etch and total-etch adhesive after ozone treatment (2) bond failure interface using a modified Adhesive Remnant Index (ARI).Methods: 52 premolars were randomly assigned into four groups (n=13) and received the following treatments: Group 1: 30 s Ozone (Biozonix, Ozonytron, Vehos Medikal, Ankara, Turkey) application + Transbond Plus Self-Etching Primer (SEP) (3M) + Transbond XT (3M), Group 2: Transbond Plus SEP + Transbond XT, Group 3: 30 s Ozone application + 37% orthophosphoric acid + Transbond XT Primer (3M) + Transbond XT, Group 4: 37% orthophosphoric acid + Transbond XT Primer + Transbond XT. All samples were stored in deionised water at 37oC for 24 hours. Shear debonding test was performed by applying a vertical force to the base of the bracket at a cross-head speed of 1 mm/min.Results: The mean SBS results were Group 1: 10.48 MPa; Group 2: 8.89 MPa; Group 3: 9.41 MPa; Group 4: 9.82 MPa. One-Way Variance Test revealed that the difference between the groups was not statistically significant (P=0.267). Debonded brackets were examined by an optical microscope at X16 magnification to determine the bond failure interface using a modified ARI. The results were (mean) Group 1: 2.38; Group 2: 1.31; Group 3: 3.00; Group 4: 1.92. Multiple comparisons showed that Groups 1 and 2, 2 and 3, 3 and 4 were statistically different (P=0.014, P<.001 and P=0.025).Conclusions: Ozone treatment prior to bracket bonding does not affect the shear bond strength. (Eur J Dent 2010;4:367-373)


2007 ◽  
Vol 31 (1) ◽  
pp. 35-40 ◽  
Author(s):  
Carla Miranda ◽  
Luiz Henrique Maykot Prates ◽  
Ricardo de Souza Vieira ◽  
Maria Cristina Marino Calvo

The aims of this study were to evaluate the shear bond strength (SBS) of four adhesive systems applied to primary dentin and enamel and verify, after SBS testing, the failure mode of the adhesive interface. Sixty extracted sound primary molars were selected and crowns were sectioned in a mesial-distal direction. Specimens were randomly assigned into two groups (adhesion to enamel and adhesion to dentin) and then subdivided into four subgroups according to the adhesive system (n=15): Scotchbond Multi-Purpose (SMP) – Single Bond (SB) – Clearfil SE Bond (and Adper Prompt LPop (APL) – SBS tests were performed and the obtained values were statistically analyzed using ANOVA and Tukey tests (p&lt;0.05). The failure mode analysis was performed with a Scanning Electron Microscope (XL-30, Philips). SBS mean values on enamel were [MPa (SD)]: SMP – 27.89 (7.49); SB – 23.92 (8.8); CSB – 24.36 (6.69); APL – 25.96 (4.08); and on dentin: SMP – 17.29 (4.25); SB – 18.2 (8.74); CSB – 16.13 (7.14); APL – 6.04 (3.35). The predominant failure mode was cohesive (primarily of the bonding agent). On enamel SBS was statistically similar for all four adhesives. On dentin SBS of APL was lower than the other tested adhesives.


2014 ◽  
Vol 62 (4) ◽  
pp. 365-370 ◽  
Author(s):  
Ricardo Alves dos SANTOS ◽  
Eliane Alves de LIMA ◽  
Mônica Maria de Albuquerque PONTES ◽  
Alexandre Batista Lopes do NASCIMENTO ◽  
Marcos Antônio Japiassú Resende MONTES ◽  
...  

OBJECTIVE: To assess the bond strength to dentin of the Single Bond (3M ESPE) and XP Bond (Dentsply) total-etch and Adper SE Plus (3M ESPE) self-etch adhesive systems. METHODS: Fifteen healthy human third molars were randomly allocated across three different groups of five teeth each according to the adhesive system. The occlusal portion of each tooth was removed under refrigeration using a flexible diamond disc (EXTEC, Enfield, CT, USA) down to an area of dentin that did not reveal enamel, as confirmed under a 40X stereo microscope (Ramsor, São Paulo, Brazil). A standardized smear layer was created with #600 grit silicon-carbide paper. The adhesive systems were applied as per manufacturer recommendations, with the exception of the Adper SE Plus system, which was triple-polymerized. Composite resin blocks (5 mm) were placed on the dentin surface. The specimens were stored in distilled water for 24 hours at 37ºC. Using a flexible diamond disc (EXTEC, Enfield, CT, USA), toothpick-like specimens with an adhesive area of less than 1 mm² were obtained. A microtensile bond test was then carried out using a universal testing machine (KRATOS) with a crosshead speed of 0.5 mm/min. Analysis of variance (ANOVA) and Tukey's test were used for comparisons. RESULTS: The bond strength values obtained with each adhesive system were as follows: XP Bond, 96.24 MPa; Adper Single Bond, 72.39 MPa; Adper SE Plus, 49.91 MPa. CONCLUSION: In terms of bond strength to dentin, conventional adhesives outperform self-etching systems.


2020 ◽  
Vol 2020 ◽  
pp. 1-7
Author(s):  
Mariana Almeida Mello Proença ◽  
Karime Tavares Lima da Silva ◽  
Alisson Costa e Silva ◽  
Edilausson Moreno Carvalho ◽  
José Bauer ◽  
...  

Objectives. The aim of this study was to evaluate the shear bond strength of metal brackets bonded with different universal adhesive systems containing 10-MDP and Transbond Plus Self Etching Primer after 20,000 thermal cycles. Materials and Methods. A total of 130 sound bovine teeth were used, which are divided into 5 groups (n = 26) according to the adhesive system used: All-Bond Universal (Bisco), Ambar Universal (FGM), Clearfil Universal Bond (Kuraray), Single Bond Universal (3M/ESPE), and Transbond Plus SEP (3M/ESPE) as control. The adhesives were applied for 20 seconds and bonded with a resin Transbond XT (3M/ESPE). After this, the teeth were submitted to 20,000 cycles at 5°C and 55°C. Afterwards, the shear bond strength test was performed in a universal test machine (Instron 3342). The adhesive remnant index (ARI) was evaluated under a stereomicroscope at 10x magnification and scanning electronic microscopy (SEM, Hitachi 3030). The shear bond strength data were submitted to One-Way ANOVA (α = 0.05) and the ARI to the Kruskal–Wallis test (α = 0.05). Results. Statistical analysis showed that the universal adhesive systems presented mean shear bond strength values similar to Transbond Plus SEP (p<0.05). The universal adhesive presented similar ARI values among them but differed from those of Transbond Plus SEP (p<0.001). Transbond Plus SEP presented a high ARI value when compared with the universal adhesive systems and high demineralization of enamel. Conclusions. The results show that universal adhesive systems may be used for bonding metal brackets if the orthodontist wants to maintain dental enamel health.


Author(s):  
Tubayesha Hassan ◽  
MH Sattar

As a means of regular practice in orthodontics and aesthetic dentistry, resin based adhesive systems are being used exclusively. Keeping up with the ever-increasing demand for aesthetic dental treatment all over the world, newer and more improved adhesive systems have been developed. However, regarding the comparison as to which bonding system performs better in clinical perspective, there is lack of existing scientific review articles. In this review, we tend to explore the conventional etch and rinse bonding system and the self-etch primer bonding system. The different tests to assess and compare bond strength between these two types of adhesives from various bibliography are discussed. The results of shear bond strength test, adhesive remnant index (ARI), enamel-adhesive interface using scanning electron microscope (SEM) and the effect of saliva contamination and time are discussed. Interestingly, each system has its strengths and weaknesses. In shear bond strength, self-etch bonding systems clearly exhibits less strength than conventional bonding systems. Resin tags into enamel surface are shorter in self-etch primer adhesives which results from milder etching to enamel compared to the conventional aid-etch and rinse adhesives. Contrarily, the irreversible changes to enamel surface is more aggressive in conventional acid-etching which states that self-etching systems are better according to the principles of minimal intervention dentistry. Ban J Orthod & Dentofac Orthop, April 2017; Vol-7 (1-2), P.20-26


Sign in / Sign up

Export Citation Format

Share Document