scholarly journals Effect of Surface Treatments on the Bond Strength to Turkom-Cera All-ceramic Material

2016 ◽  
Vol 17 (11) ◽  
pp. 920-925 ◽  
Author(s):  
Bandar MA Al-Makramani ◽  
Fuad A Al-Sanabani ◽  
Abdul AA Razak ◽  
Mohamed I Abu-Hassan ◽  
Ibrahim Z AL-Shami ◽  
...  

ABSTRACT Aim The aim of this study was to evaluate the effect of surface treatments on shear bond strength (SBS) of Turkom-Cera (Turkom-Ceramic (M) Sdn. Bhd., Puchong, Malaysia) all-ceramic material cemented with resin cement Panavia-F (Kuraray Medical Inc., Okayama, Japan). Materials and methods Forty Turkom-Cera ceramic disks (10 mm × 3 mm) were prepared and randomly divided into four groups. The disks were wet ground to 1000-grit and subjected to four surface treatments: (1) No treatment (Control), (2) sandblasting, (3) silane application, and (4) sandblasting + silane. The four groups of 10 specimens each were bonded with Panavia-F resin cement according to manufacturer's recommendations. The SBS was determined using the universal testing machine (Instron) at 0.5 mm/min crosshead speed. Failure modes were recorded and a qualitative micromorphologic examination of different surface treatments was performed. The data were analyzed using the one-way analysis of variance (ANOVA) and Tukey honestly significant difference (HSD) tests. Results The SBS of the control, sandblasting, silane, and sandblasting + silane groups were: 10.8 ± 1.5, 16.4 ± 3.4, 16.2 ± 2.5, and 19.1 ± 2.4 MPa respectively. According to the Tukey HSD test, only the mean SBS of the control group was significantly different from the other three groups. There was no significant difference between sandblasting, silane, and sandblasting + silane groups. Conclusion In this study, the three surface treatments used improved the bond strength of resin cement to Turkom-Cera disks. Clinical significance The surface treatments used in this study appeared to be suitable methods for the cementation of glass infiltrated all-ceramic restorations. How to cite this article Razak AAA, Abu-Hassan MI, AL-Makramani BMA, AL-Sanabani FA, AL-Shami IZ, Almansour HM. Effect of Surface Treatments on the Bond Strength to Turkom-Cera All-Ceramic Material. J Contemp Dent Pract 2016;17(11):920-925.

2017 ◽  
Vol 15 (4) ◽  
pp. 258
Author(s):  
Marcelo Giannini ◽  
Andreia Assis Carvalho ◽  
Ariovaldo Stefani ◽  
Wladimir Franco de Sá Barbosa ◽  
Lawrence Gonzaga Lopes

Self-adhesive, dual-polymerizing resin cements require no treatment to the prepared tooth surfaces before cementation. Aim: The aim of this study was to evaluate the influence of curing mode on bond strength (BS) of three cementing systems to bovine dentin. Methods: The buccal enamel surfaces of 50 bovine incisors were removed to expose dentin and to flat the surface. The teeth were divided into five groups (n=10), which consisted of two resin cements (Multilink and Clearfil SA Cement) that were tested in dual- (halogen light for 40 s) and self-cured modes, and a control (RelyX ARC). Two cylinders of resin cements (1.0 mm X 0.75 mm) were prepared on each bonded dentin surface. After 24h at 37oC, resin cylinders were subjected to micro-shear testing in a universal testing machine (4411/Instron - 0.5 mm/min). Data were statistically analyzed by two-way ANOVA, Tukey and Dunnett`s test (5%). Results: Multilink showed higher BS than those observed on Clearfil SA. Light-curing resulted in higher BS for both Multilink and Clearfil SA. When Multilink was light-cured, no significant difference on BS was demonstrated between it and RelyX ARC. Conclusions: The highest BS values were obtained in control group and light-cured Multilink resin cement.


2018 ◽  
Vol 6 (3) ◽  
pp. 548-553 ◽  
Author(s):  
Bandar M. A. Al–Makramani ◽  
Abdul A. A. Razak ◽  
Mohamed I. Abu–Hassan ◽  
Fuad A. Al–Sanabani ◽  
Fahad M. Albakri

BACKGROUND: The selection of the appropriate luting cement is a key factor for achieving a strong bond between prepared teeth and dental restorations.AIM: To evaluate the shear bond strength of Zinc phosphate cement Elite, glass ionomer cement Fuji I, resin-modified glass ionomer cement Fuji Plus and resin luting cement Panavia-F to Turkom-Cera all-ceramic material.MATERIALS AND METHODS: Turkom-Cera was used to form discs 10mm in diameter and 3 mm in thickness (n = 40). The ceramic discs were wet ground, air - particle abraded with 50 - μm aluminium oxide particles and randomly divided into four groups (n = 10). The luting cement was bonded to Turkom-Cera discs as per manufacturer instructions. The shear bond strengths were determined using the universal testing machine at a crosshead speed of 0.5 mm/min. The data were analysed using the tests One Way ANOVA, the nonparametric Kruskal - Wallis test and Mann - Whitney Post hoc test.RESULTS: The shear bond strength of the Elite, Fuji I, Fuji Plus and Panavia F groups were: 0.92 ± 0.42, 2.04 ± 0.78, 4.37 ± 1.18, and 16.42 ± 3.38 MPa, respectively. There was the statistically significant difference between the four luting cement tested (p < 0.05).CONCLUSION: the phosphate-containing resin cement Panavia-F exhibited shear bond strength value significantly higher than all materials tested.


2013 ◽  
Vol 14 (4) ◽  
pp. 675-680
Author(s):  
Khalil Aleisa

ABSTRACT Statement of the problem Post retention is crucial factor in restoration survival. Posts are commonly failed due to loss of retention. It is unknown which luting agents would provide the maximum bond strength for Locator overdenture posts. Aim The aim of this study was to evaluate the bond retentive strengths of Locator overdenture posts cemented with 7 luting agents. Materials and methods One hundred and five single rooted human teeth were decoronated and randomly assigned to 7 groups (n = 15). Post spaces were prepared with Locator post drills to the depth of 6 mm. The Locator posts were cemented with Variolink II, RelyX ARC, Multilink N, RelyX Unicem, ParaCore, or MultiCore Flow resin luting agents. Zinc phosphate cement was served as control group. Specimens were stored in water at 37°C for 24 hours. Each specimen was loaded in tension in an Instron universal testing machine. The maximum force required to dislodge each Locator post was recorded. Means and standard deviations were calculated and data were statistically analyzed with one-way analysis of variance (ANOVA). Results The highest mean bond strength value for Locator posts was recorded for MultiCore® Flow group (mean = 550.1 N), while the lowest mean value was for RelyX Unicem™ resin cement group (mean = 216.8 N). A statistically significant difference in mean locator overdenture post bond strength was observed between the 7 cement types (p < 0.0001). ParaCore™ and MultiCore® Flow groups had significantly higher bond strength than all other groups, but they were not differed from each other. Conclusion Bond strength of Locator overdenture posts were influenced by the type of luting agents. MultiCore Flow and ParaCore resin cements offered the greatest retention. Clinical significance The type of luting agents had a significant effect on the retention of Locator posts. The use of Core buildup resin cements as luting agent with Locator post demonstrated the greatest retention. How to cite this article Aleisa K. Bond Strength of Overdenture Locator Posts Cemented with Seven Luting Agents. J Contemp Dent Pract 2013;14(4):675-680.


2017 ◽  
Vol 16 ◽  
pp. 1-7
Author(s):  
Bruna Genari ◽  
Vicente Castelo Branco Leitune ◽  
João Henrique Macedo Saucedo ◽  
Susana Maria Werner Samuel ◽  
Fabrício Mezzomo Collares

Self-adhesive, dual-polymerizing resin cements require no treatment to the prepared tooth surfaces before cementation. Aim: The aim of this study was to evaluate the influence of curing mode on bond strength (BS) of three cementing systems to bovine dentin. Methods: The buccal enamel surfaces of 50 bovine incisors were removed to expose dentin and to flat the surface. The teeth were divided into five groups (n=10), which consisted of two resin cements (Multilink and Clearfil SA Cement) that were tested in dual- (halogen light for 40 s) and self-cured modes, and a control (RelyX ARC). Two cylinders of resin cements (1.0 mm X 0.75 mm) were prepared on each bonded dentin surface. After 24h at 37oC, resin cylinders were subjected to micro-shear testing in a universal testing machine (4411/Instron - 0.5 mm/min). Data were statistically analyzed by two-way ANOVA, Tukey and Dunnett`s test (5%). Results: Multilink showed higher BS than those observed on Clearfil SA. Light-curing resulted in higher BS for both Multilink and Clearfil SA. When Multilink was light-cured, no significant difference on BS was demonstrated between it and RelyX ARC. Conclusions: The highest BS values were obtained in control group and light-cured Multilink resin cement.


2020 ◽  
Vol 2 (1) ◽  
pp. 29-35
Author(s):  
Ulysses Lenz ◽  
Rodrigo Alessandretti ◽  
Alvaro Della Bona

Background: It’s shown that the clinical success of ceramic restorations much depends on the quality and durability of the bond to ceramic. For zirconia-based ceramics (Y-TZP), the surface treatment has a substantial impact on bond strength. Therefore, the bond strength evaluation of Y-TZP surface treatments is a requirement for predicting the clinical performance of such restorations. Objective: Evaluating the resin bond strength to Y-TZP after different surface treatments. Methods: Monolithic Y-TZP (Zenostar Zr Translucent, Wieland Dental, Rosbach vor der Höhe, Germany) blocks were bonded to resin composite blocks using a resin-based cement system after two Y-TZP surface treatments: APA- airborne particle abrasion with alumina particles; and CJ- silicatization (Cojet sand, 3M ESPE, St. Paul, MN, USA). A silane coupling agent and an adhesive system were applied to the treated Y-TZP surfaces and resin composite blocks were cemented (RelyX Ultimate, 3M ESPE, St. Paul, MN, USA) and light activated from all sides. These structures were cut to obtain bar-shaped specimens (n=30), which were stored in 37ºC distilled water for 7 days before microtensile testing. Specimens were loaded to failure under tension using a universal testing machine. Data was statistically analyzed using Students t test (α=0.05) and Weibull distribution. Failure modes were evaluated using optical (OM) and scanning electron microscopy (SEM). Results: Mean bond strength values (CJ= 25.7±8.2 MPa; APA= 22.0±6.3 MPa) were statistically similar (p>0.05). No difference was found for the characteristic strengths (σ0) and for Weibull moduli (m) since the confidence intervals (95% CI) overlapped. The bond strength values for a 5% failure probability (σ5%) were 12.4 (CJ) and 11.5 (APA). All fractures were due to cohesive failure within the adhesive cement system. Conclusion: Both Y-TZP surface treatments (CJ and APA) produced similar structural reliability and short-term bond strength to a resin cement system.


Author(s):  
Tugba Serin Kalay ◽  
Yakup Kara ◽  
Sengul alpay Karaoglu ◽  
Sevgi Kolaylı

Background: Antimicrobial agents are recommended for disinfection of the cavity following mechanical dental caries removal prior to application of restorative material. There is limited information about stabilized chlorine dioxide (ClO2) as a cavity disinfectant. Objective: The objective of this study is to determine the antimicrobial activity and effect on dentin bond strength of ClO2 compared to chlorhexidine digluconate (CHX), sodium hypochlorite (NaOCl) and ethanolic propolis extract (EPE). Methods: Antimicrobial activities of agents against oral pathogens (Staphylococcus aureus, Enterococcus faecalis, Streptococcus mutans, Lactobacillus acidophilus, Lactobacillus casei, Candida albicans, and Saccharomyces cerevisiae) and analyses of EPE were examined. Seventy-five mandibular third molars were sectioned, prepared and divided into five subgroups (n=15/group). Cavity disinfectants (2% CHX, 2.5% NaOCl, 30% EPE, 0.3% ClO2) were applied to etched dentin prior to adhesive and composite build-up. Shear bond strength (SBS) was evaluated with a universal testing machine at a crosshead speed of 0.5 mm/min. The SBS data were analyzed with one-way analysis of variance (ANOVA) and Tukey’s post-hoc test (p <0.05). The failure modes were evaluated with a stereomicroscope. Results: It was determined that the compared disinfectants were showed different inhibition zone values against oral pathogens. ClO2 exhibited the highest antimicrobial activity, followed by CHX, NaOCI and EPE, respectively. No statistically significant difference was observed in the SBS values between the disinfectant treated groups and control group. The failure modes were predominantly mixed. Conclusion: The use of 0.3% stabilized ClO2 as a cavity disinfectant agent exhibited high antimicrobial activity against oral pathogens and no adverse effects on SBS to etched dentin.


2021 ◽  
Vol 12 ◽  
pp. e6-e6
Author(s):  
Rahab Ghoveizi ◽  
Rozbeh Parsirad ◽  
Sara Tavakolizadeh ◽  
Elaheh Beyabanaki

Introduction: This study investigated the effect of various laser powers on the shear bond strength (SBS) of resin cement to the zirconia surface. Methods: Seventy-five zirconia disks were prepared and assigned to five groups including no surface treatment (control group), sandblasting with 50 µ Al2 O3 particles (second group), and Nd:YAG laser treatments with 2 W, 2.5 W and 3 W powers respectively (third, fourth and fifth groups). Afterwards, composite resin cylinders were cemented on zirconia disks using dual-curing resin cement. Before thermocycling (2000 cycles, 5-55°C), all samples were placed in distilled water at 37°C for 24 hours. Using a universal testing machine at the crosshead speed of 0.5 mm/min, the SBS was examined. Also, using a stereomicroscope, the failure type was determined. Data analyses were performed using Welch and Games-Howell tests (P< 0.05). Results: The mean bond strength difference between the control group and the other groups was significant. The respective bond strength from the highest to the lowest was observed in the sandblast group, the laser group with 2.5 W power, the laser group with 3 W power, the laser group with 2 W power, and finally the control group. However, no significant difference was observed between different laser groups (P< 0.05). Also, there was no significant difference between the sandblast and laser groups with 2.5 W and 3 W power (P< 0.05). Most of the failures in the sandblasting and laser groups with powers of 2.5 W and 3 W were mixed, but in the control and 2 W laser groups, most of the failures were of adhesive nature. Conclusion: The highest bond strength was achieved by sandblasting with Al2 O3 particles and then using an Nd: YAG laser with a power of 2.5 W.


2020 ◽  
Vol 23 (1) ◽  
Author(s):  
Menna Ahmed ElGendy ◽  
Ihab Mosleh ◽  
Hanaa Zaghloul

Objective: the purpose of the study was to evaluate the micro-shear bond strength of different cements to translucent zirconia before and after thermocycling aging. Material and methods: Twelve translucent zirconia ceramic discs were used in the study. Specimens were sandblasted using 50 ‎μm aluminum oxide (Al2O3) particles. The specimens were divided into three groups (n = 4) according to the cement type: Panavia resin cement (control group), resin modified glass ionomer (RMGI), and Activa bioactive cement. Each group was further sub-divided into two equal subgroups (n = 2) according to whether the specimens were subjected to thermocycling or not. Thermocycling was performed in distilled water at 5000 cycles between 5 oC - 55 oC. The micro-shear bond strength test (μSBS) was measured using universal testing machine. Kruskal-Wallis test was used to compare between the three cements. Dunn’s test was used for pair-wise comparisons when Kruskal-Wallis test is significant. Mann-Whitney U test was used to compare between micro-shear bond strength before and after thermocycling P ≤ 0.05. Results: In non-aged subgroups, there was no significant difference between Panavia and Activa; both showed significantly the highest mean μSBS values (22.9 MPa, 31.3 MPa respectively). While, RMGI showed the lowest μSBS values (4.7 MPa).  In thermocycled subgroups, Panavia showed significantly the highest mean μSBS values (32.2 MPa). There was no significant difference between RMGI and Activa; both showed the lowest significant mean μSBS values (3.2 MPa and 8.7 MPa respectively). Conclusions: RMGI and Activa couldn’t be considered long-term reliable materials for cementing zirconia. However, Panavia provided the most durable bond to zirconia.KEYWORDSBioactive cement; Micro-shear bond strength; Resin cement; Translucent zirconia.


2019 ◽  
Vol 13 (3) ◽  
pp. 227-233
Author(s):  
Tahereh Ghaffari ◽  
Elnaz Moslehifard ◽  
Mehrnaz Motiei

Background. Due to the fragile nature of all-ceramic restorations, it is necessary to provide an appropriate (core) infrastructure to support the veneering porcelain. The veneer detachment and chipping are disadvantages of these restorations. Several techniques have been proposed to minimize these problems. This study evaluated the effect of thermal and mechanical cycles on the shear bond strength of zirconia core to porcelain veneer under different surface treatments. Methods. Sixty disk-like zirconium samples were randomly divided into three groups. The first group was polished and veneered with porcelain, without additional surface treatments. The two other groups were subjected to different surface treatments (modified aluminum oxide by silica and activator‒aluminum oxide and primer) and veneering with porcelain. Half of the samples in each group were subjected to 6000 thermal cycles and 20,000 masticatory cycles of 50 N to imitate the intraoral conditions; the other half were placed in distilled water at 37°C until the shear strength test. Each sample was then buried using PMMA in a mounting jig so that the gap between the core and the veneer could be placed upward. Then, they were exposed to shear stress using a universal testing machine at a rate of 1 mm/min until fracture. The maximum force leading to the fracture was recorded. Results. Comparison of the groups showed that the highest shear bond strength was related to the samples treated with aluminum oxide and primer, without applying thermal and masticatory cycles, which indicated no significant difference from the group treated with aluminum oxide and primer, with thermal and masticatory cycles. The lowest shear bond strengths were related to the polished samples without surface treatment by applying thermal and masticatory cycles (P=0.001), which indicated no significant difference from the untreated group without thermal and masticatory cycles. Conclusion. Based on the results, treatment with aluminum oxide and primer increased the shear bond strength of zirconia core to porcelain veneer. Thermocycling and masticatory cycles failed to reduce the shear bond strength in all the three groups significantly.


2015 ◽  
Vol 26 (1) ◽  
pp. 50-55 ◽  
Author(s):  
Mansour Rismanchian ◽  
Amin Davoudi ◽  
Elham Shadmehr

Connecting prostheses to the implant abutments has become a concern and achieving a satisfactory retention has been focused in cement-retention prostheses recently. Sandblasting is a method to make a roughened surface for providing more retention. The aim of this study was to compare effects of nano and micro airborne abrasive particles (ABAP) in roughening surface of implant abutments and further retention of cemented copings. Thirty Xive abutments and analogues (4.5 D GH1) were mounted vertically in self-cured acrylic blocks. Full metal Ni-Cr copings with a loop on the top were fabricated with appropriate marginal adaptation for each abutment. All samples were divided into 3 groups: first group (MPS) was sandblasted with 50 µm Al2O3 micro ABAP, second group (NSP) was sandblasted with 80 nm Al2O3 nano ABAP, and the third group (C) was assumed as control. The samples were cemented with provisional cement (Temp Bond) and tensile bond strength of cemented copings was evaluated by a universal testing machine after thermic cycling. The t test for independent samples was used for statistical analysis by SPSS software (version 15) at the significant level of 0.05. Final result showed significant difference among all groups (p<0.001) and MPS manifested the highest mean retention (207.88±45.61 N) with significant difference among other groups (p<0.001). The control group showed the lowest bond strength as predicted (48.95±10.44 N). Using nano or micro ABAP is an efficient way for increasing bond strengths significantly, but it seems that micro ABAP was more effective.


Sign in / Sign up

Export Citation Format

Share Document