scholarly journals New Approaches For Analyzing Hot Water & Other Systems

Author(s):  
Edward W. Saltzberg

Historically, Analyzing A Hot Water System To Establish Why A System May Run Out Of Hot Water, Why Temperature Fluctuations Occur In Showers, And How Long Are The Delays In Getting Hot Water To Fixtures, Was A Time-Consuming And Kind Of A Hit And Miss Operation. These Tasks Encompassed Having Service Personnel Review The Operation Of The Water Heater, Do Calculations To See That The Water Heater Was The Proper Size, Ascertain What The Physical Configuration Of The Hot Water System Was, And The Lengths Of Various Piping Segments, And Lastly, Take Temperature Readings At Various Locations And Times Throughout The System. Some Of This Data Could Be Obtained With Continuous Temperature Monitoring Equipment, But It Was Very Laborious And The Continuous Chart Recorders Generated Temperature Printout Charts At The Rate Of Two Inches Per Hour, Which Meant Quite A Long Chart For Each Test. Furthermore, The Temperature Readings At Times Could Be Extremely Confusing, As They Overlapped, And It Was Difficult To Find The Maximum And Minimum Points And Discover Repetitive Patterns On The Long Charts.

2014 ◽  
Vol 587-589 ◽  
pp. 243-246
Author(s):  
Chu Ping Lu ◽  
Kai Ji

This paper is as an example of the hot water supply of the hotel in the city,The design of the hot water system is the solar energy and the air source heat pump,includes:the selection calculation of the air source heat pump of the water heater , the selection and calculation of the solar collector,the determination of the thermal storage tank and the determination of the circulating water pump of heat collecting .


1988 ◽  
Vol 5 (4) ◽  
pp. 423-431
Author(s):  
H.P. Garg ◽  
N.K. Bansal ◽  
D.S. Hrishikesan

2013 ◽  
Vol 6 (2) ◽  
pp. 99-114 ◽  
Author(s):  
E. J. Pieterse-Quirijns ◽  
E. J. M. Blokker ◽  
E. van der Blom ◽  
J. H. G. Vreeburg

Abstract. Existing Dutch guidelines for the design of the drinking water and hot water system of non-residential buildings are based on outdated assumptions on peak water demand or on unfounded assumptions on hot water demand. They generally overestimate peak demand values required for the design of an efficient and reliable water system. Recently, a procedure was developed based on the end-use model SIMDEUM to derive design-demand-equations for peak demand values of both cold and hot water during various time steps for several types and sizes of non-residential buildings, viz. offices, hotels and nursing homes. In this paper, the design-demand-equations are validated with measurements of cold and hot water patterns on a per second base and with surveys. The good correlation between the simulated water demand patterns and the measured patterns indicates that the basis of the design-demand-equations, the SIMDEUM simulated standardised buildings, is solid. Surveys were held to investigate whether the construction of the standardised buildings based on the dominant variable corresponds with practice. Surveys show that it is difficult to find relationships to equip the standardised buildings with users and appliances. However, the validation proves that with a proper estimation of the number of users and appliances in only the dominant functional room of the standardised buildings, SIMDEUM renders a realistic cold and hot water diurnal demand pattern. Furthermore, the new design-demand-equations based on these standardised buildings give a better prediction of the measured peak values for cold water flow than the existing guidelines. Moreover, the new design-demand-equations can predict hot water use well. In this paper it is illustrated that the new design-demand-equations lead to reliable and improved designs of building installations and water heater capacity, resulting in more hygienic and economical installations.


2012 ◽  
Vol 5 (1) ◽  
pp. 455-471
Author(s):  
E. J. Pieterse-Quirijns ◽  
E. J. M. Blokker ◽  
E. van der Blom ◽  
J. H. G. Vreeburg

Abstract. Existing guidelines related to the water demand of non-residential buildings are outdated and do not cover hot water demand for the appropriate selection of hot water devices. Moreover, they generally overestimate peak demand values required for the design of an efficient and reliable water system. Recently, a procedure was developed based on the end-use model SIMDEUM® to derive design rules for peak demand values of both cold and hot water during various time steps for several types and sizes of non-residential buildings, i.e. offices, hotels and nursing homes. In this paper, the design rules are validated with measurements of cold and hot water patterns on a per second base. The good correlation between the simulated patterns and the measured patterns indicates that the basis of the design rules, the SIMDEUM simulated standardised buildings, is solid. Moreover, the SIMDEUM based rules give a better prediction of the measured peak values for cold water flow than the existing guidelines. Furthermore, the new design rules can predict hot water use well. In this paper it is illustrated that the new design rules lead to reliable and improved designs of building installations and water heater capacity, resulting in more hygienic and economical installations.


2010 ◽  
Vol 171-172 ◽  
pp. 368-373
Author(s):  
Jing Lv ◽  
Jie Yang

In this paper a gas cooler for trans-critical carbon dioxide water heater was designed and calculated according to the theory basis for the optimal design. The characteristic parameters of gas cooler in heat pump hot water system were compared and analyzed, applying the data from trans-critical carbon dioxide water heater test bed, under one-time heating condition, by different flow of chilled water and hot water, different inlet temperatures of chilled water and hot water. To sum up, coefficient of performance can be increased by increasing the chilled water inlet temperature or hot water circulating flow, while it can be decreased by increasing the inlet temperature of hot water circulating system,the parameters (flow of water, inlet temperature, the refrigerant mass flow, gas cooler pressure and inlet temperature of refrigerant) need to be adjusted to different requirements, for ensuring the high efficiency of system.


2010 ◽  
Vol 45 (1) ◽  
pp. 99-109
Author(s):  
Martin B. Hocking

Abstract In a case study, this paper responds to increasing public interest in water quality issues by investigating chemical changes as water passes through a domestic water hot water system. Elemental changes were measured by simultaneous analysis of the incoming and outgoing water streams and the deposited sediment from an electric water heater tank. The results may alter some long-held beliefs. The collected and dried sediment from the tank was analyzed for thirty common elements by inductively coupled plasma and atomic absorption techniques. Of the 25 elements found, the dominant seven in order of concentration were magnesium, aluminum, copper, zinc, manganese, iron, and sodium, as well as some surprising traces of other elements. The cold water input and the heated output were also analyzed for thirteen measurable elements. In the heated water output, magnesium had a massive 151% increase in concentration, followed by much more modest increases shown by arsenic, calcium, lead, potassium, silicon, and strontium. None of these mass balance changes compromised the potability of the water. The six elements, aluminum, boron, copper, iron, manganese, and sodium, showed decreases in aqueous concentrations on heating, thereby improving the water quality.


2012 ◽  
Vol 23 (1) ◽  
pp. 33-40 ◽  
Author(s):  
Jacob G. Fantidis ◽  
Dimitrios V. Bandekas ◽  
Constantinos Potolias ◽  
Nick Vordos ◽  
Kostas Karakoulidis

The use of solar thermal collectors is an economic alternative for water heating. In Greece more than 4 million m2 of collector area has been installed; however, the financial and economic crisis has dealt the solar thermal market a heavy blow. The aim of the paper is twofold: firstly, to present the new legislations and combined efforts taken by the government in order to give the solar thermal market a boost; secondly, to evaluate the effect of these efforts and calculate the new financial data from the citizens. For the promotion of solar water heaters, new legislations and concerted efforts are taken by the government. The effect of the new incentive program on the payback time of a typical glazed solar hot water system in Greece was investigated in this work. Long-term meteorological data from 47 stations are analyzed in order to evaluate the potential of solar water heater application at each site in Greece. The RETScreen software was used to predict the financial viability and the green house gas emissions reductions. The economical indicators showed that Tymbakion was the best site and Ioannina the worst. From the environmental point of view, it was found that on an average an approximate quantity of 1.47 ton of green house gases can be avoided entering into the local atmosphere each year.DOI: http://dx.doi.org/10.5755/j01.ee.23.1.1222


2016 ◽  
Vol 108 ◽  
pp. 230-239 ◽  
Author(s):  
Inès Boppe ◽  
Emilie Bédard ◽  
Catherine Taillandier ◽  
Daphné Lecellier ◽  
Marc-André Nantel-Gauvin ◽  
...  

foresight ◽  
2016 ◽  
Vol 18 (6) ◽  
pp. 586-602
Author(s):  
Rekha Raju ◽  
Manish Kumar ◽  
Manoj Changat

Purpose The purpose of this study is to show how scenario-based forecasting can give a better understanding of future commercial potential of a newly developed technology. This study aims to bridge the existing gaps in technology commercialization process for various projects supported under innovation support schemes in India. Design/methodology/approach The scope of this study is to understand the commercial potential and future deployment prospect of “sun direct hot water system (SDHWS)”. Scenarios have been drawn using “cone of plausibility” method and the commercial potential forecasted under different scenarios using arithmetic and linear regression forecasting tool. Findings The SDHWS is an incremental innovation but has great potential to overcome major constraints and barriers associated with existing solar water heater (SWH) technologies. Among the three scenarios drawn, plausible scenario is most likely to happen in future. The SDHWS is technically and economically capable of replacing existing conventional systems of SWHs. Research limitations/implications The study is limited to developing alternate qualitative scenarios and, further, an attempt to quantify the commercial potential. Various assumptions have been taken because of non-availability of past data on SDHWS technology. Originality/value Scenario-based forecasting to understand commercial potential for innovative technology is a new approach. The adoption of such insight and analysis would brighten the chance of SDHWS technology to reach the market.


2012 ◽  
Vol 512-515 ◽  
pp. 303-306
Author(s):  
Xue Lai Liu ◽  
Guan Zhu Wang ◽  
Yong An Li ◽  
Xiao Feng Zhang

This article describes the solar hot water system, and establishes the computational model of hot water system. It analyzes the economical efficiency of solar water heaters which equipped with electric water heaters, gas water heaters and air-source heat pump water heaters. The results show that the initial investment of the system which equipped with an electric water heater and a gas water heater is almost, but the operating cost which equipped with a gas water heater system is lower. The operating cost which equipped with an air-source heat pump water heater is the lowest, though the initial investment is the highest. The solar hot water system which equipped with an air-source heat pump water heater has important reference value for going low-carbon economy road in China.


Sign in / Sign up

Export Citation Format

Share Document