Designing and Researching of Gas Cooler in Trans-Critical Carbon Dioxide Water Heater

2010 ◽  
Vol 171-172 ◽  
pp. 368-373
Author(s):  
Jing Lv ◽  
Jie Yang

In this paper a gas cooler for trans-critical carbon dioxide water heater was designed and calculated according to the theory basis for the optimal design. The characteristic parameters of gas cooler in heat pump hot water system were compared and analyzed, applying the data from trans-critical carbon dioxide water heater test bed, under one-time heating condition, by different flow of chilled water and hot water, different inlet temperatures of chilled water and hot water. To sum up, coefficient of performance can be increased by increasing the chilled water inlet temperature or hot water circulating flow, while it can be decreased by increasing the inlet temperature of hot water circulating system,the parameters (flow of water, inlet temperature, the refrigerant mass flow, gas cooler pressure and inlet temperature of refrigerant) need to be adjusted to different requirements, for ensuring the high efficiency of system.

2006 ◽  
Vol 129 (2) ◽  
pp. 226-234
Author(s):  
Robert Hendron ◽  
Mark Eastment ◽  
Ed Hancock ◽  
Greg Barker ◽  
Paul Reeves

Building America (BA) partner McStain Neighborhoods built the Discovery House in Loveland, CO, with an extensive package of energy-efficient features, including a high-performance envelope, efficient mechanical systems, a solar water heater integrated with the space-heating system, a heat-recovery ventilator (HRV), and ENERGY STAR appliances. The National Renewable Energy Laboratory (NREL) and Building Science Consortium conducted short-term field-testing and building energy simulations to evaluate the performance of the house. These evaluations are utilized by BA to improve future prototype designs and to identify critical research needs. The Discovery House building envelope and ducts were very tight under normal operating conditions. The HRV provided fresh air at a rate of about 35L∕s(75cfm), consistent with the recommendations of ASHRAE Standard 62.2. The solar hot water system is expected to meet the bulk of the domestic hot water (DHW) load (>83%), but only about 12% of the space-heating load. DOE-2.2 simulations predict whole-house source energy savings of 54% compared to the BA Benchmark (Hendron, R., 2005 NREL Report No. 37529, NREL, Golden, CO). The largest contributors to energy savings beyond McStain’s standard practice are the solar water heater, HRV, improved air distribution, high-efficiency boiler, and compact fluorescent lighting package.


2006 ◽  
Vol 17 (3) ◽  
pp. 65-70 ◽  
Author(s):  
V Mittal ◽  
K S Kasana ◽  
N S Thakur

This paper presents modelling and simulation of a solar absorption cooling system. In this paper, the modelling of a solar-powered, single stage, absorption cooling system, using a flat plate collector and water–lithium bromide solution, is done. A computer program has been developed for the absorption system to simulate various cycle configurations with the help of various weather data for the village Bahal, District Bhiwani, Haryana, India. The effects of hot water inlet temperatures on the coefficient of performance (COP) and the surface area of the absorption cooling component are studied. The hot water inlet temperature is found to affect the surface area of some of the system components. Moreover the effect of the reference temperature which is the minimum allowable hot water inlet temperature on the fraction of total load met by non-purchased energy (FNP) and coefficient of performance (COP) is studied and it is found that high reference temperature increases the system COP and decreases the surface area of system components but lower reference temperature gives better results for FNP than high reference temperatures.


Author(s):  
Robert Hendron ◽  
Mark Eastment ◽  
Ed Hancock ◽  
Greg Barker ◽  
Paul Reeves

Building America (BA) partner McStain Neighborhoods built the Discovery House in Loveland, Colorado, with an extensive package of energy-efficient features, including a high-performance envelope, efficient mechanical systems, a solar water heater integrated with the space-heating system, a heat-recovery ventilator (HRV), and ENERGY STAR™ appliances. The National Renewable Energy Laboratory (NREL) and Building Science Consortium (BSC) conducted short-term field-testing and building energy simulations to evaluate the performance of the house. These evaluations are utilized by BA to improve future prototype designs and to identify critical research needs. The Discovery House building envelope and ducts were very tight under normal operating conditions. The HRV provided fresh air at a rate of about 75 cfm (35 l/s), consistent with the recommendations of ASHRAE Standard 62.2. The solar hot water system is expected to meet the bulk of the domestic hot water (DHW) load (>83%), but only about 12% of the space-heating load. DOE-2.2 simulations predict whole-house source energy savings of 54% compared to the BA Benchmark [1]. The largest contributors to energy savings beyond McStain’s standard practice are the solar water heater, HRV, improved air distribution, high-efficiency boiler, and compact fluorescent lighting package.


Author(s):  
R. Chacartegui ◽  
D. Sa´nchez ◽  
F. Jime´nez-Espadafor ◽  
A. Mun˜oz ◽  
T. Sa´nchez

The development of high efficiency solar power plants based on gas turbine technology presents two problems, both of them directly associated with the solar power plant receiver design and the power plant size: lower turbine intake temperature and higher pressure drops in heat exchangers than in a conventional gas turbine. To partially solve these problems, different configurations of combined cycles composed of a closed cycle carbon dioxide gas turbine as topping cycle have been analyzed. The main advantage of the Brayton carbon dioxide cycle is its high net shaft work to expansion work ratio, in the range of 0.7–0.85 at supercritical compressor intake pressures, which is very close to that of the Rankine cycle. This feature will reduce the negative effects of pressure drops and will be also very interesting for cycles with moderate turbine inlet temperature (800–1000 K). Intercooling and reheat options are also considered. Furthermore, different working fluids have been analyzed for the bottoming cycle, seeking the best performance of the combined cycle in the ranges of temperatures considered.


2014 ◽  
Vol 587-589 ◽  
pp. 243-246
Author(s):  
Chu Ping Lu ◽  
Kai Ji

This paper is as an example of the hot water supply of the hotel in the city,The design of the hot water system is the solar energy and the air source heat pump,includes:the selection calculation of the air source heat pump of the water heater , the selection and calculation of the solar collector,the determination of the thermal storage tank and the determination of the circulating water pump of heat collecting .


1988 ◽  
Vol 5 (4) ◽  
pp. 423-431
Author(s):  
H.P. Garg ◽  
N.K. Bansal ◽  
D.S. Hrishikesan

Author(s):  
Yahya I. Sharaf-Eldeen ◽  
Craig V. Muccio ◽  
Eric Gay

This work involves measurements, analyses, and evaluations of the performance of add-on, Heat Pump Water Heater (HPWH) systems in residential and small commercial applications. Two air-source Heat Pump (HP) systems rated at 7,000- and 12,000-BTU (2.051- and 3.517-kWh), were utilized in this work. The two HPs were retrofitted to two 50-gallon (189.3 liters) electric-resistance storage water-heaters with their electric heating elements removed. A third, standard electric water-heater (EWH), was used for comparison. The testing set-up was fully instrumented for measurements of pertinent parameters, including inlet and outlet water temperatures, inlet and outlet air temperatures of the HPs, temperature and humidity of the air in the surrounding space, volume of water draws out of the storage heater tanks, as well as electric energy consumptions of the systems. Several performance measures were used in this work, including the Coefficient of Performance (COP), which is a measure of the instantaneous energy output in comparison with the energy input; Energy Factor (EF), which is an average measure of the COP taken over extended periods of time; and the First Hour Rating (FHR), which is a measure of the maximum volume of hot water that a storage type water-heater can supply to a residence within an hour. The results obtained clearly indicate that, HPWH systems are much more efficient as compared to standard EWHs. While the average value of the EF for a standard EWH is close to 1.0, the HPWH systems yield EFs averaging more than 2.00, resulting in annual energy savings averaging more than 50%. The results also showed that, HPWH systems are effective at reducing utility peak demand-loads, in addition to providing substantial cost savings to consumers.


Energies ◽  
2019 ◽  
Vol 12 (3) ◽  
pp. 479
Author(s):  
Ignacio Paniagua ◽  
Ángel Álvaro ◽  
Javier Martín ◽  
Celina Fernández ◽  
Rafael Carlier

Although CO 2 as refrigerant is well known for having the lowest global warming potential (GWP), and commercial domestic heat pump water heater systems exist, its long expected wide spread use has not fully unfolded. Indeed, CO 2 poses some technological difficulties with respect to conventional refrigerants, but currently, these difficulties have been largely overcome. Numerous studies show that CO 2 heat pump water heaters can improve the coefficient of performance (COP) of conventional ones in the given conditions. In this study, the performances of transcritical CO 2 and R410A heat pump water heaters were compared for an integrated nearly zero-energy building (NZEB) application. The thermodynamic cycle of two commercial systems were modelled integrating experimental data, and these models were then used to analyse both heat pumps receiving and producing hot water at equal temperatures, operating at the same ambient temperature. Within the range of operation of the system, it is unclear which would achieve the better COP, as it depends critically on the conditions of operation, which in turn depend on the ambient conditions and especially on the actual use of the water. Technology changes on each side of the line of equal performance conditions of operation (EPOC), a useful design tool developed in the study. The transcritical CO 2 is more sensitive to operating conditions, and thus offers greater flexibility to the designer, as it allows improving performance by optimising the global system design.


2013 ◽  
Vol 6 (2) ◽  
pp. 99-114 ◽  
Author(s):  
E. J. Pieterse-Quirijns ◽  
E. J. M. Blokker ◽  
E. van der Blom ◽  
J. H. G. Vreeburg

Abstract. Existing Dutch guidelines for the design of the drinking water and hot water system of non-residential buildings are based on outdated assumptions on peak water demand or on unfounded assumptions on hot water demand. They generally overestimate peak demand values required for the design of an efficient and reliable water system. Recently, a procedure was developed based on the end-use model SIMDEUM to derive design-demand-equations for peak demand values of both cold and hot water during various time steps for several types and sizes of non-residential buildings, viz. offices, hotels and nursing homes. In this paper, the design-demand-equations are validated with measurements of cold and hot water patterns on a per second base and with surveys. The good correlation between the simulated water demand patterns and the measured patterns indicates that the basis of the design-demand-equations, the SIMDEUM simulated standardised buildings, is solid. Surveys were held to investigate whether the construction of the standardised buildings based on the dominant variable corresponds with practice. Surveys show that it is difficult to find relationships to equip the standardised buildings with users and appliances. However, the validation proves that with a proper estimation of the number of users and appliances in only the dominant functional room of the standardised buildings, SIMDEUM renders a realistic cold and hot water diurnal demand pattern. Furthermore, the new design-demand-equations based on these standardised buildings give a better prediction of the measured peak values for cold water flow than the existing guidelines. Moreover, the new design-demand-equations can predict hot water use well. In this paper it is illustrated that the new design-demand-equations lead to reliable and improved designs of building installations and water heater capacity, resulting in more hygienic and economical installations.


2014 ◽  
Vol 137 (1) ◽  
Author(s):  
M. Alkhair ◽  
M. Y. Sulaiman ◽  
K. Sopian ◽  
C. H. Lim ◽  
E. Salleh ◽  
...  

The modeling of the performance of a one refrigeration ton (RT) solar assisted adsorption air-conditioning refrigeration system using activated carbon fiber/ethanol as the adsorbent/adsorbate pair has been undertaken in this study. The effects of hot water, cooling water, chilled water inlet temperatures, and hot water and chilled water flow rates were taken into consideration in the optimization of the system and in the design of the condenser, evaporator, and hot water storage tank. The study includes analysis of the weather data and its effect on both the adsorption system and the cooling load. This is then followed by estimation of the cooling capacity and coefficient of performance (COP) of the adsorption system as a function of the input parameters. The results of the model will be compared to experimental data in a next step.