scholarly journals Four Fourier transform spectrometers and the Arctic polar vortex: instrument intercomparison and ACE-FTS validation at Eureka during the IPY springs of 2007 and 2008

2009 ◽  
Vol 2 (6) ◽  
pp. 2881-2917 ◽  
Author(s):  
R. L. Batchelor ◽  
F. Kolonjari ◽  
R. Lindenmaier ◽  
R. L. Mittermeier ◽  
W. Daffer ◽  
...  

Abstract. The Canadian Arctic Atmospheric Chemistry Experiment Validation Campaigns have been carried out at Eureka, Nunavut (80.05° N, 86.42° W) during the polar sunrise period since 2004. During the International Polar Year (IPY) springs of 2007 and 2008, three ground-based Fourier transform infrared (FTIR) spectrometers were operated simultaneously. This paper presents a comparison of trace gas measurements of stratospherically important species involved in ozone depletion, namely O3, HCl, ClONO2, HNO3 and HF, recorded with these three spectrometers. Total column densities of the gases measured with the new Canadian Network for the Detection of Atmospheric Change (CANDAC) Bruker 125HR are shown to agree to within 3.5% with the existing Environment Canada Bomem DA8 measurements. After smoothing both of these sets of measurements to account for the lower spectral resolution of the University of Waterloo Portable Atmospheric Research Interferometric Spectrometer for the Infrared (PARIS-IR), the measurements were likewise shown to agree with PARIS-IR to within 7%. Concurrent measurements of these gases were also made with the satellite-based Atmospheric Chemistry Experiment Fourier Transform Spectrometer (ACE-FTS) during overpasses of Eureka during these time periods. While one of the mandates of the ACE satellite mission is to study ozone depletion in the polar spring, previous validation exercises have identified the highly variable polar vortex conditions of the spring period to be a challenge for validation efforts. In this work, comparisons between the CANDAC Bruker 125HR and ACE-FTS have been used to develop strict criteria that allow the ground- and satellite-based instruments to be confidently compared. When these criteria are taken into consideration, there is shown to be no significant bias between the ACE-FTS and ground-based FTIR spectrometer for any of these gases.

2010 ◽  
Vol 3 (1) ◽  
pp. 51-66 ◽  
Author(s):  
R. L. Batchelor ◽  
F. Kolonjari ◽  
R. Lindenmaier ◽  
R. L. Mittermeier ◽  
W. Daffer ◽  
...  

Abstract. The Canadian Arctic Atmospheric Chemistry Experiment Validation Campaigns have been carried out at Eureka, Nunavut (80.05° N, 86.42° W) during the polar sunrise period since 2004. During the International Polar Year (IPY) springs of 2007 and 2008, three ground-based Fourier transform infrared (FTIR) spectrometers were operated simultaneously. This paper presents a comparison of trace gas measurements of stratospherically important species involved in ozone depletion, namely O3, HCl, ClONO2, HNO3 and HF, recorded with these three spectrometers. Total column densities of the gases measured with the new Canadian Network for the Detection of Atmospheric Change (CANDAC) Bruker 125HR are shown to agree to within 3.5% with the existing Environment Canada Bomem DA8 measurements. After smoothing both of these sets of measurements to account for the lower spectral resolution of the University of Waterloo Portable Atmospheric Research Interferometric Spectrometer for the Infrared (PARIS-IR), the measurements were likewise shown to agree with PARIS-IR to within 7%. Concurrent measurements of these gases were also made with the satellite-based Atmospheric Chemistry Experiment Fourier Transform Spectrometer (ACE-FTS) during overpasses of Eureka during these time periods. While one of the mandates of the ACE satellite mission is to study ozone depletion in the polar spring, previous validation exercises have identified the highly variable polar vortex conditions of the spring period to be a challenge for validation efforts. In this work, comparisons between the CANDAC Bruker 125HR and ACE-FTS have been used to develop strict criteria that allow the ground- and satellite-based instruments to be confidently compared. When these criteria are taken into consideration, the observed biases between the ACE-FTS and ground-based FTIR spectrometer are not persistent for both years and are generally insignificant, though small positive biases of ~5%, comparable in magnitude to those seen in previous validation exercises, are observed for HCl and HF in 2007, and negative biases of −15.3%, −4.8% and −1.5% are seen for ClONO2, HNO3 and O3 in 2008.


2020 ◽  
Vol 12 (6) ◽  
pp. 917
Author(s):  
Tomi Karppinen ◽  
Otto Lamminpää ◽  
Simo Tukiainen ◽  
Rigel Kivi ◽  
Pauli Heikkinen ◽  
...  

We analyzed the vertical distribution of atmospheric methane (CH 4 ) retrieved from measurements by ground-based Fourier Transform Spectrometer (FTS) instrument in Sodankylä, Northern Finland. The retrieved dataset covers 2009–2018. We used a dimension reduction retrieval method to extract the profile information, since each measurement contains around three pieces of information about the profile shape between 0 and 40 km. We compared the retrieved profiles against Atmospheric Chemistry Experiment Fourier Transform Spectrometer (ACE-FTS) satellite measurements and AirCore balloon-borne profile measurements. Additional comparison at the lowest tropospheric layer was done against in-situ measurements from a 50-m-high mast. In general, the ground-based FTS and ACE-FTS profiles agreed within 10% below 20 km and within 30% in the stratosphere between 20 and 40 km. Our method was able to accurately capture reduced methane concentrations inside the polar vortex in the Arctic stratosphere. The method produced similar trend characteristics as the reference instruments even when a static prior profile was used. Finally, we analyzed the time series of the CH 4 profile datasets and estimated the trend using the dynamic linear model (DLM).


2008 ◽  
Vol 8 (6) ◽  
pp. 1763-1788 ◽  
Author(s):  
A. Fraser ◽  
F. Goutail ◽  
K. Strong ◽  
P. F. Bernath ◽  
C. Boone ◽  
...  

Abstract. The first three Canadian Arctic ACE validation campaigns were held during polar sunrise at Eureka, Nunavut, Canada (80° N, 86° W) from 2004 to 2006 in support of validation of the ACE (Atmospheric Chemistry Experiment) satellite mission. Three or four zenith-sky viewing UV-visible spectrometers have taken part in each of the three campaigns. The differential slant column densities and vertical column densities of ozone and NO2 from these instruments have been compared following the methods of the UV-visible Working Group of the NDACC (Network for Detection of Atmospheric Composition Change). The instruments are found to partially agree within the required accuracies for both species, although both the vertical and slant column densities are more scattered than required. This might be expected given the spatial and temporal variability of the Arctic stratosphere in spring. The vertical column densities are also compared to integrated total columns from ozonesondes and integrated partial columns from the ACE-FTS (ACE-Fourier Transform Spectrometer) and ACE-MAESTRO (ACE-Measurements of Aerosol Extinction in the Stratosphere and Troposphere Retrieved by Occultation) instruments on board ACE. For both species, the columns from the ground-based instruments and the ozonesondes are found to generally agree within their combined error bars. The ACE-FTS ozone partial columns and the ground-based total columns agree within 4.5%, averaged over the three campaigns. The ACE-MAESTRO ozone partial columns are generally smaller than those of the ground-based instruments, by an average of 9.9%, and are smaller than the ACE-FTS columns by an average of 14.4%. The ACE-FTS NO2 partial columns are an average of 13.4% smaller than the total columns from the ground-based instruments, as expected. The ACE-MAESTRO NO2 partial columns are larger than the total columns of the ground-based instruments by an average of 2.5% and are larger than the partial columns of the ACE-FTS by an average of 15.5%.


2006 ◽  
Vol 6 (8) ◽  
pp. 2355-2366 ◽  
Author(s):  
G. Dufour ◽  
R. Nassar ◽  
C. D. Boone ◽  
R. Skelton ◽  
K. A. Walker ◽  
...  

Abstract. From January to March 2005, the Atmospheric Chemistry Experiment high resolution Fourier transform spectrometer (ACE-FTS) on SCISAT-1 measured many of the changes occurring in the Arctic (50–80° N) lower stratosphere under very cold winter conditions. Here we focus on the partitioning between the inorganic chlorine reservoirs HCl and ClONO2 and their activation into ClO. The simultaneous measurement of these species by the ACE-FTS provides the data needed to follow chlorine activation during the Arctic winter and the recovery of the Cl-reservoir species ClONO2 and HCl. The time evolution of HCl, ClONO2 and ClO as well as the partitioning between the two reservoir molecules agrees well with previous observations and with our current understanding of chlorine activation during Arctic winter. The results of a chemical box model are also compared with the ACE-FTS measurements and are generally consistent with the measurements.


2006 ◽  
Vol 6 (1) ◽  
pp. 1249-1273 ◽  
Author(s):  
G. Dufour ◽  
R. Nassar ◽  
C. D. Boone ◽  
R. Skelton ◽  
K. A. Walker ◽  
...  

Abstract. From January to March 2005, the Atmospheric Chemistry Experiment high resolution Fourier transform spectrometer (ACE-FTS) on SCISAT-1 measured many of the changes occurring in the Arctic (50–80° N) lower stratosphere under very cold winter conditions. Here we focus on the partitioning between the inorganic chlorine reservoirs HCl and ClONO2 and their activation into ClO. The simultaneous measurement of these species by the ACE-FTS provides the data needed to follow chlorine activation during the Arctic winter and the recovery of the Cl-reservoir species ClONO2 and HCl. The time evolution of HCl, ClONO2 and ClO as well as the partitioning between the two reservoir molecules agrees well with previous observations and with our current understanding of chlorine activation during Arctic winter. The results of a chemical box model are also compared with the ACE-FTS measurements and are generally consistent with the measurements.


2020 ◽  
Author(s):  
Kaley Walker ◽  
Kimberly Strong ◽  
Pierre Fogal ◽  
James R. Drummond

<p>Ground-based measurements provide critical data to validate satellite retrievals of atmospheric trace gases and to assess the long-term stability of these measurements.  As of February 2020, the Canadian-led Atmospheric Chemistry Experiment (ACE) satellite mission has been making measurements of the Earth's atmosphere for nearly sixteen years and Canada's Optical Spectrograph and InfraRed Imager System (OSIRIS) instrument on the Odin satellite has been operating for over sixteen years.  As ACE and OSIRIS continue to operate far beyond their planned two-year missions, there is an ongoing need to validate the trace gas profiles from the ACE-Fourier Transform Spectrometer (ACE-FTS), the Measurement of Aerosol Extinction in the Stratosphere and Troposphere Retrieved by Occultation (ACE-MAESTRO) and OSIRIS.  In particular, validation comparisons are needed during Arctic springtime to understand better the measurements of species involved in stratospheric ozone chemistry.</p><p>To this end, seventeen Canadian Arctic ACE/OSIRIS Validation Campaigns have been conducted during the spring period (February - April in 2004 - 2020) at the Polar Environment Atmospheric Research Laboratory (PEARL) in Eureka, Nunavut (80N, 86W). For more than a decade, these campaigns have been undertaken in collaboration with the Canadian Network for the Detection of Atmospheric Change (CANDAC). The spring period coincides with the most chemically active time of year in the Arctic, as well as a significant number of satellite overpasses. A suite of as many as 13 ground-based instruments, as well as frequent balloon-borne ozonesonde and radiosonde launches, have been used in each campaign. These instruments include: a ground-based version of the ACE-FTS (PARIS - Portable Atmospheric Research Interferometric Spectrometer), a terrestrial version of the ACE-MAESTRO, a SunPhotoSpectrometer, two CANDAC zenith-viewing UV-visible grating spectrometers, a Bomem DA8 Fourier transform spectrometer, the CANDAC Bruker 125HR Fourier transform spectrometer, an EM27/SUN Fourier transform spectrometer, a Systeme d’Analyse par Observations Zenithales (SAOZ) instrument, a Pandora spectrometer, and several Brewer spectrophotometers. In the past several years, these results have been used to validate the measurements by the ACE-FTS, ACE-MAESTRO, and OSIRIS instruments as well as the TANSO-FTS instrument on the Japanese Greenhouse Gases Observing Satellite (GOSAT) and the TROPOMI instrument on the Sentinel 5 Precursor. This presentation will focus on an overview of the measurements made by the ground-based, balloon-borne and satellite-borne instruments during the recent ACE/OSIRIS Arctic Validation campaigns and highlight how these have been used for satellite validation.</p>


2007 ◽  
Vol 7 (6) ◽  
pp. 16283-16347 ◽  
Author(s):  
A. Fraser ◽  
F. Goutail ◽  
K. Strong ◽  
P. F. Bernath ◽  
C. Boone ◽  
...  

Abstract. The first three Canadian Arctic ACE validation campaigns were held during polar sunrise at Eureka, Nunavut, Canada (80° N, 86° W) from 2004 to 2006 in support of validation of the ACE (Atmospheric Chemistry Experiment) satellite mission. Three or four zenith-sky viewing UV-visible spectrometers have taken part in each of the three campaigns. The differential slant column densities and vertical column densities from these instruments have been compared following the methods of the UV-visible Working Group of the NDACC (Network for Detection of Atmospheric Composition Change). The instruments are found to partially agree within the required accuracies for both species, although both the vertical and slant column densities are more scattered than required. This might be expected given the spatial and temporal variability of the Arctic stratosphere in spring. The vertical column densities are also compared to integrated total columns from ozonesondes and integrated partial columns from the ACE-FTS (ACE-Fourier Transform Spectrometer) and ACE-MAESTRO (ACE-Measurements of Aerosol Extinction in the Stratosphere and Troposphere Retrieved by Occultation) instruments on board ACE. For both species, the columns from the ground-based instruments and the ozonesondes are found to generally agree within their combined error bars. The ACE-FTS ozone partial columns and the ground-based total columns agree within 4.5%, averaged over the three campaigns. The ACE-MAESTRO ozone partial columns are generally smaller than those of the ground-based instruments, by an average of 9.9%, and are smaller than the ACE-FTS columns by an average of 14.4%. The ACE-FTS NO2 partial columns are an average of 13.4% smaller than the total columns from the ground-based instruments, as expected. The ACE-MAESTRO NO2 partial columns are larger than the total columns of the ground-based instruments by an average of 2.5% and larger than the partial columns of the ACE-FTS by an average of 15.5%.


2021 ◽  
Author(s):  
Ramina Alwarda ◽  
Kristof Bognar ◽  
Kimberly Strong ◽  
Martyn Chipperfield ◽  
Sandip Dhomse ◽  
...  

<p>The Arctic winter of 2019-2020 was characterized by an unusually persistent polar vortex and temperatures in the lower stratosphere that were consistently below the threshold for the formation of polar stratospheric clouds (PSCs). These conditions led to ozone loss that is comparable to the Antarctic ozone hole. Ground-based measurements from a suite of instruments at the Polar Environment Atmospheric Research Laboratory (PEARL) in Eureka, Canada (80.05°N, 86.42°W) were used to investigate chemical ozone depletion. The vortex was located above Eureka longer than in any previous year in the 20-year dataset and lidar measurements provided evidence of polar stratospheric clouds (PSCs) above Eureka. Additionally, UV-visible zenith-sky Differential Optical Absorption Spectroscopy (DOAS) measurements showed record ozone loss in the 20-year dataset, evidence of denitrification along with the slowest increase of NO<sub>2</sub> during spring, as well as enhanced reactive halogen species (OClO and BrO). Complementary measurements of HCl and ClONO<sub>2</sub> (chlorine reservoir species) from a Fourier transform infrared (FTIR) spectrometer showed unusually low columns that were comparable to 2011, the previous year with significant chemical ozone depletion. Record low values of HNO<sub>3</sub> in the FTIR dataset are in accordance with the evidence of PSCs and a denitrified atmosphere. Estimates of chemical ozone loss were derived using passive ozone from the SLIMCAT offline chemical transport model to account for dynamical contributions to the stratospheric ozone budget.</p>


2008 ◽  
Vol 8 (3) ◽  
pp. 505-522 ◽  
Author(s):  
G. L. Manney ◽  
W. H. Daffer ◽  
K. B. Strawbridge ◽  
K. A. Walker ◽  
C. D. Boone ◽  
...  

Abstract. The first three Arctic winters of the ACE mission represented two extremes of winter variability: Stratospheric sudden warmings (SSWs) in 2004 and 2006 were among the strongest, most prolonged on record; 2005 was a record cold winter. Canadian Arctic Atmospheric Chemistry Experiment (ACE) Validation Campaigns were conducted at Eureka (80° N, 86° W) during each of these winters. New satellite measurements from ACE-Fourier Transform Spectrometer (ACE-FTS), Sounding of the Atmosphere using Broadband Emission Radiometry (SABER), and Aura Microwave Limb Sounder (MLS), along with meteorological analyses and Eureka lidar temperatures, are used to detail the meteorology in these winters, to demonstrate its influence on transport, and to provide a context for interpretation of ACE-FTS and validation campaign observations. During the 2004 and 2006 SSWs, the vortex broke down throughout the stratosphere, reformed quickly in the upper stratosphere, and remained weak in the middle and lower stratosphere. The stratopause reformed at very high altitude, near 75 km. ACE measurements covered both vortex and extra-vortex conditions in each winter, except in late-February through mid-March 2004 and 2006, when the strong, pole-centered vortex that reformed after the SSWs resulted in ACE sampling only inside the vortex in the middle through upper stratosphere. The 2004 and 2006 Eureka campaigns were during the recovery from the SSWs, with the redeveloping vortex over Eureka. 2005 was the coldest winter on record in the lower stratosphere, but with an early final warming in mid-March. The vortex was over Eureka at the start of the 2005 campaign, but moved away as it broke up. Disparate temperature profile structure and vortex evolution resulted in much lower (higher) temperatures in the upper (lower) stratosphere in 2004 and 2006 than in 2005. Satellite temperatures agree well with lidar data up to 50–60 km, and ACE-FTS, MLS and SABER show good agreement in high-latitude temperatures throughout the winters. Consistent with a strong, cold upper stratospheric vortex and enhanced radiative cooling after the SSWs, MLS and ACE-FTS trace gas measurements show strongly enhanced descent in the upper stratospheric vortex in late January through March 2006 compared to that in 2005.


2015 ◽  
Vol 8 (10) ◽  
pp. 11171-11207
Author(s):  
E. M. Buzan ◽  
C. A. Beale ◽  
C. D. Boone ◽  
P. F. Bernath

Abstract. This paper presents an analysis of observations of methane and its two major isotopologues, CH3D and 13CH4 from the Atmospheric Chemistry Experiment (ACE) satellite between 2004 and 2013. Additionally, atmospheric methane chemistry is modeled using the Whole Atmospheric Community Climate Model (WACCM). ACE retrievals of methane extend from 6 km for all isotopologues to 75 km for 12CH4, 35 km for CH3D, and 50 km for 13CH4. While total methane concentrations retrieved from ACE agree well with the model, values of δD–CH4 and δ13C–CH4 show a bias toward higher δ compared to the model and balloon-based measurements. Calibrating δD and δ13C from ACE using WACCM in the troposphere gives improved agreement in δD in the stratosphere with the balloon measurements, but values of δ13C still disagree. A model analysis of methane's atmospheric sinks is also performed.


Sign in / Sign up

Export Citation Format

Share Document