Testing in sandbox experiments the potentialities of active-Distributed Temperature Sensing to quantify distributed groundwater fluxes in porous media

Author(s):  
Olivier Bour ◽  
Nataline Simon ◽  
Nicolas Lavenant ◽  
Gilles Porel ◽  
Benoit Nauleau ◽  
...  

<p>Active-Distributed Temperature Sensing is a new method that has been recently developed for quantifying groundwater fluxes in the sub-surface along fibre-optic cables with a great spatial resolution. It consists in measuring and modelling the increase of temperature due to a heat source, dissipated through heat conduction and heat advection, depending on groundwater fluxes. Here, we propose to estimate the applicability and limitations of the method using sandbox experiments where flow rate and temperature are well controlled. For doing so, active-DTS experiments have been achieved under different flow rates and experimental conditions. In addition, we compare three different and complementary methods to estimate in practice the spatial resolution of DTS measurements. </p><p>Active-DTS experiments have been conducted by deploying a fiber optic cable in a large PVC tank (1.6m long; 1.2 m width and 0.3 m height) and filled with 0.4-1.3 mm diameter sand. The height of water in water reservoirs on either side of the sandbox can be adjusted to control the head gradient and the flow rate through the sand. Heating was done by injecting during at least 8 hours for each experiment, a well-controlled electrical current along the steel armouring of the fiber optic cable. The three methods for estimating spatial resolution were applied and compared using FO-DTS measurements obtained on the same fiber-optic cable but with two different DTS units having different spatial resolution. Results show that a large range of groundwater fluxes may be estimated with a very good accuracy. Finally, we compare the advantages and complementarities of the different methods proposed for estimating the spatial resolution of measurements. In particular, the spatial resolution estimated using a temperature step change is both dependent on the effective spatial resolution of the DTS unit but also on heat conduction induced because of the high thermal conductivity of the cable. By showing the applicability of the method for a large range of flow rates and with an excellent spatial resolution, these experiments demonstrate the potentialities of the method for quantifying fluid fluxes in porous media for a large range of applications.</p>

Sensors ◽  
2021 ◽  
Vol 21 (11) ◽  
pp. 3723
Author(s):  
Robert Wu ◽  
Pierrick Lamontagne-Hallé ◽  
Jeffrey M. McKenzie

Actively heated fiber-optic distributed temperature sensing (aFO-DTS) measures soil moisture content at sub-meter intervals across kilometres of fiber-optic cable. The technology has great potential for environmental monitoring but calibration at field scales with variable soil conditions is challenging. To better understand and quantify the errors associated with aFO-DTS soil moisture measurements, we use a parametric numerical modeling approach to evaluate different error factors for uniform soil. A thermo-hydrogeologic, unsaturated numerical model is used to simulate a 0.01 m by 0.01 m two-dimensional domain, including soil and a fiber-optic cable. Results from the model are compared to soil moisture values calculated using the commonly used Tcum calibration method for aFO-DTS. The model is found to have high accuracy between measured and observed saturations for static hydrologic conditions but shows discrepancies for more realistic settings with active recharge. We evaluate the performance of aFO-DTS soil moisture calculations for various scenarios, including varying recharge duration and heterogeneous soils. The aFO-DTS accuracy decreases as the variability in soil properties and intensity of recharge events increases. Further, we show that the burial of the fiber-optic cable within soil may adversely affect calculated results. The results demonstrate the need for careful selection of calibration data for this emerging method of measuring soil moisture content.


Sensors ◽  
2020 ◽  
Vol 20 (2) ◽  
pp. 570 ◽  
Author(s):  
Nataline Simon ◽  
Olivier Bour ◽  
Nicolas Lavenant ◽  
Gilles Porel ◽  
Benoît Nauleau ◽  
...  

For many environmental applications, the interpretation of fiber-optic Raman distributed temperature sensing (FO-DTS) measurements is strongly dependent on the spatial resolution of measurements, especially when the objective is to detect temperature variations over small scales. Here, we propose to compare three different and complementary methods to estimate, in practice, the “effective” spatial resolution of DTS measurements: The classical “90% step change” method, the correlation length estimated from experimental semivariograms, and the derivative method. The three methods were applied using FO-DTS measurements achieved during sandbox experiments using two DTS units having different spatial resolutions. Results show that the value of the spatial resolution estimated using a step change depends on both the effective spatial resolution of the DTS unit and on heat conduction induced by the high thermal conductivity of the cable. The correlation length method provides an estimate much closer to the value provided by the manufacturers, representative of the effective spatial resolutions along cable sections where temperature gradients are small or negligible. Thirdly, the application of the derivative method allows for verifying the representativeness of DTS measurements all along the cable, by localizing sections where measurements are representative of the effective temperature. We finally show that DTS measurements could be validated in sandbox experiments, when using devices with finer spatial resolution.


Author(s):  
Anton O. Chernutsky ◽  
Dmitriy A. Dvoretskiy ◽  
Ilya O. Orekhov ◽  
Stanislav G. Sazonkin ◽  
Yan Zh. Ososkov ◽  
...  

2021 ◽  
Vol 7 (20) ◽  
pp. eabe7136
Author(s):  
Robert Law ◽  
Poul Christoffersen ◽  
Bryn Hubbard ◽  
Samuel H. Doyle ◽  
Thomas R. Chudley ◽  
...  

Measurements of ice temperature provide crucial constraints on ice viscosity and the thermodynamic processes occurring within a glacier. However, such measurements are presently limited by a small number of relatively coarse-spatial-resolution borehole records, especially for ice sheets. Here, we advance our understanding of glacier thermodynamics with an exceptionally high-vertical-resolution (~0.65 m), distributed-fiber-optic temperature-sensing profile from a 1043-m borehole drilled to the base of Sermeq Kujalleq (Store Glacier), Greenland. We report substantial but isolated strain heating within interglacial-phase ice at 208 to 242 m depth together with strongly heterogeneous ice deformation in glacial-phase ice below 889 m. We also observe a high-strain interface between glacial- and interglacial-phase ice and a 73-m-thick temperate basal layer, interpreted as locally formed and important for the glacier’s fast motion. These findings demonstrate notable spatial heterogeneity, both vertically and at the catchment scale, in the conditions facilitating the fast motion of marine-terminating glaciers in Greenland.


Ground Water ◽  
2012 ◽  
Vol 51 (5) ◽  
pp. 670-678 ◽  
Author(s):  
Matthew W. Becker ◽  
Brian Bauer ◽  
Adam Hutchinson

Sign in / Sign up

Export Citation Format

Share Document