scholarly journals Efficacy of reciprocating and rotary retreatment nickel-titanium file systems for removing filling materials with a complementary cleaning method in oval canals

2021 ◽  
Vol 46 (1) ◽  
Author(s):  
Said Dhaimy ◽  
Hyeon-Cheol Kim ◽  
Lamyae Bedida ◽  
Imane Benkiran
Author(s):  
Jader Camilo Pinto ◽  
Fernanda Ferrari Esteves Torres ◽  
Airton Oliveira Santos-Junior ◽  
Marco Antonio Hungaro Duarte ◽  
Juliane Maria Guerreiro-Tanomaru ◽  
...  

Abstract Objective The aim of this study was to investigate the effect of additional apical preparation using the ProDesign Logic (PDL) 50/.01 rotary heat-treated nickel–titanium (NiTi) file with a larger diameter and minimal taper for retreatment of curved root canals. Materials and Methods Mesial curved root canals of 12 mandibular molars were prepared using PDL 25/.06 and filled using the continuous wave of condensation technique and AH Plus sealer. After retreatment using ProDesign S (PDS) 25/.08, PDL 25/.06 and PDL 35/05, a complementary procedure was performed with PDL 50/.01. Microcomputed tomography (micro-CT) scanning was performed before and after retreatment procedures. The cyclic fatigue resistance of unused PDS 25/.08, PDL 25/.06, PDL 35/.05 and PDL 50/.01 instruments (n = 12) was evaluated in a stainless-steel device. Statistical Analysis Data on the volumes of the root canals and the remaining filling materials were submitted to the paired t-test. Cyclic fatigue resistance data was submitted to one-way ANOVA and Tukey’s tests (α = 0.05). Results Use of PDL 50/.01 decreased the remaining filling materials in the apical third (p < 0.05). The root canal volume was similar in the cervical and middle thirds before and after preparation using PDL 50/.01 (p > 0.05). PDL 50/.01 presented the highest cyclic fatigue resistance (p < 0.05). Conclusions Use of the PDL 50/.01 instrument as an additional apical preparation for retreatment of curved root canals improved filling material removal in the apical third, while maintaining the dentin in the cervical and middle thirds. In addition, PDL 50/.01 presented high-flexural resistance.


2016 ◽  
Vol 10 (02) ◽  
pp. 210-214 ◽  
Author(s):  
Emel Uzunoglu ◽  
Sevinc Aktemur Turker

ABSTRACT Objective: The goal of present study was to determine the effect of different nickel–titanium file systems on the amount of apically extruded debris during endodontic retreatment: D-RaCe retreatment systems, EdgeFile XR retreatment rotary files, and Reciproc R40. Materials and Methods: Thirty-six single-rooted prepared mandibular premolar teeth were filled with Gutta-percha and AH Plus sealer. The teeth were then randomly assigned into three groups (n = 12) for retreatment. The endodontic retreatment was performed as follows: D-RaCe, EdgeFile XR, Reciproc 40. Debris extruded apically during the retreatment was collected into preweighed Eppendorf tubes. An incubator was used to store tubes at 70°C for 5 days. The initial weight was subtracted from final weight of the Eppendorf tubes to calculate the weight of the dry extruded debris for each group. The data obtained were evaluated using Welch analysis of variance and Games-Howell post-hoc tests (P < 0.05). Results: All files resulted in apical extrusion of debris. Reciproc caused significantly less debris extrusion compared to D-RaCe and EdgeFile XR (P < 0.05). Conclusions: The findings revealed that during endodontic retreatment, number, and taper of files might have an influence on the amount of apically extruded debris during endodontic retreatment.


2014 ◽  
Vol 40 (8) ◽  
pp. 1186-1189 ◽  
Author(s):  
Young-Hye Hwang ◽  
Kwang-Shik Bae ◽  
Seung-Ho Baek ◽  
Kee-Yeon Kum ◽  
WooCheol Lee ◽  
...  

2015 ◽  
Vol 16 (11) ◽  
pp. 864-868 ◽  
Author(s):  
Ebru Kucukyilmaz ◽  
Selcuk Savas ◽  
Gokhan Saygili ◽  
Banu Uysal

ABSTRACT Aim The purpose of this study was to determine the amount of extruded debris and irrigant associated with different single-file systems and one multiple-file system. Materials and methods Forty-five newly extracted single rooted primary canine teeth were used in this study. The root canals were instrumented using the reciprocating single-file system, the single-file rotary system and the multiple-file rotary system. A 10–6 precision micro-balance was used to calculate the amount of extruded debris and irrigant. The incubation period was set as 15 days at 37°C to obtain dry debris. The preparation time for instrumentation was also recorded. The data were statistically analyzed by Manova and Bonferroni adjustment. Results Considering the apically extruded debris, while there was statistically significant difference between Reciproc and OneShape groups (p < 0.05), no statistically significant difference was found among the other groups (p > 0.05). In terms of irrigation solution, although significant difference was obtained between the Reciproc and other two groups (p < 0.05), no statistically significant difference was obtained between the two rotary instruments (p > 0.05). Instrumentation was significantly faster using Reciproc than with all other instrument (p < 0.05). Conclusion All systems caused apical debris and irrigant extrusion. Full-sequences rotary instrumentation systems may be preferable for preparation primary teeth. Clinical significance This is the first study carrying out to compare both apical debris and irrigation solution extrusion with reciprocal and rotary single-file systems with other preparation systems in primary teeth. How to cite this article Kucukyilmaz E, Savas S, Saygili G, Uysal B. Evaluation of Apically Extruded Debris and Irrigant Produced by Different Nickel-Titanium Instrument Systems in Primary Teeth. J Contemp Dent Pract 2015;16(11):864-868.


2018 ◽  
Vol 47 (1) ◽  
pp. 325-334 ◽  
Author(s):  
Zhuwei Huang ◽  
Jingjing Quan ◽  
Jia Liu ◽  
Wen Zhang ◽  
Xiaolei Zhang ◽  
...  

Objective To evaluate the shaping ability of three thermally-treated rotary nickel-titanium (NiTi) systems including ProTaper Next (PTN), HyFlex™ CM (HFCM) and HyFlex™ EDM (HFEDM) during root canal preparation in simulated root canals. Methods A total of 45 simulated root canals were divided into three groups ( n = 15) and prepared with PTN, HFCM or HFEDM files up to size 25. Microcomputed tomography (microCT) was used to scan the specimens before and after instrumentation. Volume and diameter changes, transportations and centring ratios at 11 levels of the simulated root canals were measured and compared. Results HFEDM caused significantly greater volume increases than HFCM and PTN in the entire root canal and in the apical and middle thirds. HFCM removed the least amount of resin in the coronal third compared with HFEDM and PTN. Overall, HFCM caused significantly less transportation in the apical 2 mm and was better centred than PTN in the apical 3 mm. Conclusion Under the conditions of this study, all systems prepared curved canals without significant shaping errors and instrument fracture. PTN and HFCM cut less resin than HFEDM. HFCM stayed centred apically and cut the least material coronally.


2017 ◽  
Vol 68 (5) ◽  
pp. 957-961
Author(s):  
Andrea Csinszka Kovacs Ivacson ◽  
Mariana Pacurar ◽  
Monica Monea ◽  
Monika Kovacs ◽  
Mihai Pop ◽  
...  

The use of nickel-titanium instruments have become an important part of the root canal treatment, in order to facilitate the cleaning and shaping of root canals, because the incorrect utilization of the endodontic files during endodontic treatment may produce unwanted procedural errors. The aim of this study was to evaluate on simulated curved root canal models the cleaning efficiency and the apical transportation in three reference areas of the root canal files, ProTaper (Dentsply Maillefer), K3XF (Sybron Endo) and HyFlex (Coltene Endo) systems, compared to the hand K-files (DentsplyMaillefer). According to our results, rotary file systems are more efficient than the hand files, in cleaning the root canal.


Sign in / Sign up

Export Citation Format

Share Document