scholarly journals 3–5 BI-RADs Microcalcifications: Correlation between MRI and Histological Findings

ISRN Oncology ◽  
2011 ◽  
Vol 2011 ◽  
pp. 1-7 ◽  
Author(s):  
Valeria Fiaschetti ◽  
Chiara Adriana Pistolese ◽  
Tommaso Perretta ◽  
Elsa Cossu ◽  
Chiara Arganini ◽  
...  

Purpose. To evaluate the correlation between MRI and histopathological findings in patients with mammographically detected 3–5 BI-RAD (Breast Imaging Reporting And Data Systems) microcalcifications and to allow a better surgical planning. Materials and Method. 62 female Patients (age ) with screening detected 3–5 BI-RAD microcalcifications underwent dynamic 3 T contrast-enhanced breast MRI. After 30-day (range 24–36 days) period, 55 Patients underwent biopsy using stereotactic vacuum-assisted biopsy (VAB), 5 Patients underwent stereotactic mammographically guided biopsy, and 2 Patients underwent MRI-guided VAB. Results. Microhistology examination demonstrated 36 malignant lesions and 26 benign lesions. The analysis of MRI findings identified 8 cases of MRI BI-RADS 5, 23 cases of MRI BI-RADS 4, 11 cases of MRI BI-RADS 3, 4 cases type A and 7 cases type B, and 20 cases of MRI BI-RADS 1-2. MRI sensitivity, specificity, positive predictive value, and negative predictive value were 88.8%, 76.9%, 84.2%, and 83.3%, respectively.

2018 ◽  
Vol 105 (5) ◽  
pp. 378-387 ◽  
Author(s):  
Giulia Bicchierai ◽  
Jacopo Nori ◽  
Diego De Benedetto ◽  
Cecilia Boeri ◽  
Ermanno Vanzi ◽  
...  

PurposeTo evaluate the role of contrast-enhanced spectral mammography (CESM) in the post biopsy management of breast lesions classified as lesions of uncertain malignant potential (B3) by core needle biopsy and vacuum-assisted biopsy (VAB).MethodsThe local ethics committee approved this retrospective study and for this type of study formal consent is not required. A total of 42 B3 lesions in 40 women aged 41–77 years were included in our study. All patients underwent CESM 2–3 weeks after the biopsy procedure and surgical excision was subsequently performed within 60 days of the CESM procedure. Three radiologists reviewed the images independently. The results were then compared with histologic findings.ResultsThe sensitivity, specificity, and positive and negative predictive values for confirmed demonstration of malignancy at CESM were 33.3%, 87.2%, 16.7%, and 94.4% for reader 1; 66.7%, 76.9%, 18.2%, and 96.7% for reader 2; 66.7%, 74.4%, 16.7%, and 96.7% for reader 3. Overall agreement on detection of malignant lesions using CESM among readers ranged from moderate to substantial (κ = .451–.696), for categorization of BPE from moderate to substantial (κ = .562–.711), and for evaluation of lesion intensity enhancement from fair to moderate (κ = .346–.459).ConclusionIn cases of Breast Imaging Reporting and Data System (BI-RADS) 1, BI-RADS 2, or BI-RADS 3 results at CESM, follow-up or VAB rather than surgical biopsy might be performed.


Author(s):  
Reham Khalil ◽  
Noha Mohamed Osman ◽  
Nivine Chalabi ◽  
Enas Abdel Ghany

Abstract Background We aimed to evaluate the unenhanced MRI of the breast (UE-MRI) as an effective substitute for dynamic contrast-enhanced breast MRI (DCE-MRI) in both detecting and characterizing breast lesions. We enrolled in our retrospective study 125 females (232 breasts, as 18 patients had unilateral mastectomy) with breast mass at MRI of variable pathologies. Routine DCE-MRI protocol of the breast was conducted. We compared the conventional unenhanced images including STIR, T2, and DWIs to the DCE-MRI by two blinded radiologists, to detect and characterize breast lesions, and then we compared their results with the final reference diagnoses supplied by the histopathology or serial negative follow-ups. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy for UE-MRI and DCE-MRI were calculated. UE-MRI results of each observer were also compared with DCE- MRI. Results The calculated UE-MRI sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy for the first observer were 95%, 80%, 83%, 94%, and 89% respectively, and for the second observer, they were 94%, 79%, 81%, 93%, and 86%. On the other hand, those for the DCE-MRI by the first observer were 98%, 82%, 84%, 98%, and 90% and were 97%, 81%, 84%, 97%, and 89% by the second observer. The intraobserver agreement between the UE-MRI and DCE-MRI results of each observer was 94% and 95%, while the interobserver agreement for each section was 97.4% for UE-MRI and 98.3% for DCE-MRI. Conclusion UE-MRI of the breast can be a reliable and effective substitute for breast DCE-MRI. It can be used with comparable accuracy to DCE-MRI whenever contrast administration is not feasible or contraindicated.


2018 ◽  
Vol 1 ◽  
pp. 9
Author(s):  
Harshad Arvind Vanjare ◽  
Jyoti Panwar

Objective The objective of the study was to assess the accuracy of ultrasound examination for the diagnosis of rotator cuff tear and tendinosis performed by a short experienced operator, compared to magnetic resonance imaging (MRI) results. Method A total of 70 subjects suspected to have rotator cuff tear or tendinosis and planned for shoulder MRI were included in the study. Shoulder ultrasound was performed either before or after the MRI scan on the same day. Ultrasound operator had a short experience in performing an ultrasound of the shoulder. Ultrasound findings were correlated to MRI findings. Results Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy for the diagnosis of tendinosis were 58%, 84%, 63%, 80%, and 75%, respectively, and it was 68%, 91%, 73%, 88%, and 85%, respectively, for the diagnosis of rotator cuff tear. Conclusions Sensitivity for diagnosing rotator cuff tear or tendinosis was moderate but had a higher negative predictive value. Thus, the ultrasound operator with a short experience in performing shoulder ultrasound had moderate sensitivity in diagnosing tendinosis or tears; however, could exclude them with confidence.


2021 ◽  
Vol 28 (4) ◽  
pp. 2548-2559
Author(s):  
Andrzej Lorek ◽  
Katarzyna Steinhof-Radwańska ◽  
Anna Barczyk-Gutkowska ◽  
Wojciech Zarębski ◽  
Piotr Paleń ◽  
...  

Contrast-enhanced spectral mammography (CESM) is a promising, digital breast imaging method for planning surgeries. The study aimed at comparing digital mammography (MG) with CESM as predictive factors in visualizing multifocal-multicentric cancers (MFMCC) before determining the surgery extent. We analyzed 999 patients after breast cancer surgery to compare MG and CESM in terms of detecting MFMCC. Moreover, these procedures were assessed for their conformity with postoperative histopathology (HP), calculating their sensitivity and specificity. The question was which histopathological types of breast cancer were more frequently characterized by multifocality–multicentrality in comparable techniques as regards the general number of HP-identified cancers. The analysis involved the frequency of post-CESM changes in the extent of planned surgeries. In the present study, MG revealed 48 (4.80%) while CESM 170 (17.02%) MFMCC lesions, subsequently confirmed in HP. MG had MFMCC detecting sensitivity of 38.51%, specificity 99.01%, PPV (positive predictive value) 85.71%, and NPV (negative predictive value) 84.52%. The respective values for CESM were 87.63%, 94.90%, 80.57% and 96.95%. Moreover, no statistically significant differences were found between lobular and NST cancers (27.78% vs. 21.24%) regarding MFMCC. A treatment change was required by 20.00% of the patients from breast-conserving to mastectomy, upon visualizing MFMCC in CESM. In conclusion, mammography offers insufficient diagnostic sensitivity for detecting additional cancer foci. The high diagnostic sensitivity of CESM effectively assesses breast cancer multifocality/multicentrality and significantly changes the extent of planned surgeries. The multifocality/multicentrality concerned carcinoma, lobular and invasive carcinoma of no special type (NST) cancers with similar incidence rates, which requires further confirmation.


2019 ◽  
pp. 49-61
Author(s):  
A. V. Chernaya ◽  
S. N. Novikov ◽  
P. V. Krivorotko ◽  
R. Kh. Ulyanova ◽  
V. V. Danilov

Purpose: to study the possibilities of contrast enhanced dual-energy spectral mammography (CESM) in the diagnostics of malignant tumors in the breast.Material and methods. Forty-seven patients with suspicious for breast cancer (BC) lesions underwent CESM. Digital mammography (MMG) and post-contrast images were correlated with the results of path morphological studies after surgery or puncture biopsy was performed.Results. Sensitivity, specificity and overall accuracy in the diagnostics of breast cancer were 83.3%, 85.7%, 85.1% for digital mammography and 91.6%, 91.4%, 91.4% for CESM, respectively. The positive predictive value was 66.6% for digital MMG and 78.5% for CESM. The negative predictive value (NPV) was 96.9% for the CESM and exceeded NPV of the digital MMG, which was 93.7%.Conclusion. Thus, these findings suggest that CESM is an effective method for the diagnostics of malignant tumors in the breast.


Diagnostics ◽  
2020 ◽  
Vol 10 (10) ◽  
pp. 828
Author(s):  
Katsutoshi Sugimoto ◽  
Tatsuya Kakegawa ◽  
Hiroshi Takahashi ◽  
Yusuke Tomita ◽  
Masakazu Abe ◽  
...  

The Contrast-Enhanced Ultrasound Liver Imaging Reporting and Data System (CEUS LI-RADS) was introduced for classifying suspected hepatocellular carcinoma (HCC). However, it cannot be applied to Sonazoid. We assessed the diagnostic usefulness of a modified CEUS LI-RADS for HCC and non-HCC malignancies based on sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). Patients with chronic liver disease at risk for HCC were evaluated retrospectively. Nodules ≥1 cm with arterial phase hyperenhancement, no early washout (within 60 s), and contrast defects in the Kupffer phase were classified as LR-5. Nodules showing early washout, contrast defects in the Kupffer phase, and/or rim enhancement were classified as LR-M. A total of 104 nodules in 104 patients (median age: 70.0 years; interquartile range: 54.5–78.0 years; 74 men) were evaluated. The 48 (46.2%) LR-5 lesions included 45 HCCs, 2 high-flow hemangiomas, and 1 adrenal rest tumor. The PPV of LR-5 for HCC was 93.8% (95% confidence interval (CI): 82.8–98.7%). The 22 (21.2%) LR-M lesions included 16 non-HCC malignancies and 6 HCCs. The PPV of LR-M for non-HCC malignancies, including six intrahepatic cholangiocarcinomas, was 100% (95% CI: 69.8–100%). In conclusion, in the modified CEUS LI-RADS for Sonazoid, LR-5 and LR-M are good predictors of HCC and non-HCC malignancies, respectively.


2017 ◽  
Vol 71 (4) ◽  
pp. 14-18 ◽  
Author(s):  
Anna Rzepakowska ◽  
Ewelina Sielska-Badurek ◽  
Ewa Osuch-Wójcikiewicz ◽  
Michał Sobol ◽  
Kazimierz Niemczyk

Objective: To assess the sensitivity and specificity of larngovideostroboscopy (LVS) in the diagnosis of precancerous and malignant lesions of the vocal folds. Material and methods: In 175 patients (128 men and 47 women), aged 19-88 years, mean age 61.5, who were admitted to the clinic with diagnosed premalignant conditions of vocal fold mucosa (leukoplakia, chronic hypertrophic inflammatory lesions) and thickening or tumor on the vocal fold, there was performed LVS before the laryngeal microsurgery. The LVS study included: localization of the leasion, movement of the vocal folds, mucosal wave, shape of glottis clousure, amplitude and symmetry of vocal fold vibration. In the evaluation, a point scale was applied for the individual functional parameters. The scale ranged from 0 to 14. Patients with impaired vocal fold motion or absent mucosal wave were positive on LVS for malignant lesions. Those with limitted mucosal wave were positive on LVS for dysplastic lesions. The results were compared with the final histopathological examination and the sensitivity, specificity, accuracy, positive (PPV) and negative (NPV) predictive value were calculated. Results: On the basis of histopathological examination, benign lesions (normal or inflammatory mucosa) accounted for 20% of diagnoses, hypertrophy and parakeratosis for 28%, low and middle grade dysplasia accounted for 10% and malignant lesions (high-grade dysplasia, pre-invasive cancer, Invasive cancer) was diagnosed in 42% of patients. The overall mean score for LVS was 4.5 and 8.0, respectively for benign and malignant lesions. Sensitivity, specificity, accuracy, PPV and NPV of LVS in detecting malignant lesions were respectively - 95.6%, 23.8%, 61.1%, 57.6% and 83.3% and in detecting both premalignant and malignant lesions were respectively – 90.7%, 31.4%, 78.9%, 84.1% and 45.8%. Conclusions: Because of the high sensitivity of LVS in detecting precancerous and malignant lesions, this method is a very good tool for screening of pathology within the larynx.


2001 ◽  
Vol 8 (5) ◽  
pp. 399-406 ◽  
Author(s):  
Christopher P. Goscin ◽  
Claudia G. Berman ◽  
Robert A. Clark

Background Magnetic resonance imaging (MRI) has the potential to become a useful adjunct in breast imaging. Contrast-enhanced breast MRI has demonstrated a high sensitivity in the detection of invasive breast cancer. In clinical studies, breast MRI has often altered the course of patient care. Although promising results have been generated, MRI of the breast is currently in a development stage. Methods The authors reviewed the literature on the potential indications, sensitivity, specificity, and limitations of MRI of the breast. Results Reported advantages of MRI of the breast over conventional imaging techniques include improved staging and treatment planning, enhanced evaluation of the augmented breast, better detection of recurrence, and improved screening of high-risk women. Contrast-enhanced breast MRI is a sensitive modality for detecting breast cancer, but its variable specificity is a major limitation. Conclusions MRI of the breast is emerging as a valuable adjunct to mammography and sonography for specific clinical indications. Additional clinical studies that define indications, interpretation criteria, imaging parameters, and cost effectiveness are needed. A multi-institutional study designed to address these issues is in progress.


2021 ◽  
Author(s):  
Ana Maria Ghiuchici ◽  
Mirela Dănilă ◽  
Alina Popescu ◽  
Roxana Șirli ◽  
Tudor Moga ◽  
...  

Aims: to evaluate the accuracy of LR-5 category from the latest Contrast-Enhanced Ultrasound algorithm (ACR CEUS LI-RADSv 2017) for the noninvasive diagnosis of hepatocellular carcinoma (HCC), in a real-life cohort of high-risk patients. Material and methods: We retrospectively re-analysed the CEUS studies of 464 focal liver lesions (FLL) in 382 patients at high-risk for HCC (liver cirrhosis of any aetiology, chronic B or C hepatitis with severe fibrosis) using the ACR CEUS LI-RADSv 2017 algorithm. CEUS LI-RADS categories used for the diagnosis of HCC were: CEUS LR-5 (definitely HCC) and CEUS LR-TIV (HCC with macrovascular invasion). Contrast-enhanced CT, contrast-enhanced MRI, or histology were used as diagnostic reference methods to evaluate the CEUS LI-RADS classification of the 464 lesions. Results: According to the reference method, the 464 lesions were classified as follows: 359 HCCs, 68 non-HCC-non-malignant lesions and 37 non-HCC malignant lesions. The diagnostic accuracy of LR-5 category for the diagnosis of hepatocellular carcinoma was 76.9%. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were 71.9%, 94.3 %, 97.7% and 49.5%, respectively. Conclusions: LR-5 category from ACR CEUS LI-RADSv 2017 algorithm, has good sensitivity, excellent specificity, and PPV for the diagnosis of HCC. The HCC rate increases from LR-3 to LR-5.


2020 ◽  
pp. 014556132092532 ◽  
Author(s):  
Chuanyao Lin ◽  
Sisi Zhang ◽  
Ling Lu ◽  
Maohua Wang ◽  
Xiaoyun Qian

Objectives: To explore the diagnostic value and pathological correlation of narrow band imaging (NBI) classification in laryngeal lesions. Methods: A total of 112 patients (123 lesions) with laryngeal lesions from July 2018 to May 2019 were selected in this study. All patients were examined by NBI and white light imaging endoscopy. The NBI endoscopy was applied to classify the observed lesion sites according to intraepithelial papillary capillary loop pattern. The gold standard of diagnosis was pathological results. To evaluate the consistency of NBI classification and pathological results. Results: The sensitivity, specificity, positive predictive value, and negative predictive value of the diagnosis for benign, precancerous, and malignant lesions under the NBI endoscopy were 90.91%, 81.19%, 74.07%, 85.42%; 41.67%, 92.93%, 58.82%, 86.79%; and 93.51%, 65.22%, 91.14%, 68.18%, respectively. There was a high consistency between NBI classification and pathological results (κ = 0.679, P < .001). Conclusions: The NBI classification can improve the accuracy of the diagnosis of laryngeal lesions. It is important for early diagnosis and treatment of vocal cord leukoplakia and laryngeal cancer.