scholarly journals COMPARISON OF THE ADDITION OF Manihot utilisima (PATI UBI WOOD) TO DIMENSIONAL STABILITY OF IRREVERSIBLE HYDROCOLLOID MOLD

2021 ◽  
Vol 1 (Volume 1 No 1) ◽  
pp. 19-26
Author(s):  
Ilmianti ◽  
Muhammad Iqbal ◽  
Muhammad Hidayatullah

Alginate impression material is used to print the teeth and the oral tissues; alginate molding material is from abroad and expensive. Modification to the impression material alginate with cassava starch with 1: 1 obtained detailed reproduction of the same printed material alginate without added with cassava starch. The study's objective was to get an alternative form of printed material alginate plus Manihot utilisima (cassava starch) with the nature of the physical properties following the standard. The study methods used laboratory experiments. The materials used in this study were printed material alginate (Hydrogum fast setting), starch cassava starch cap dua kelinci, water, and tools calliper inside digital. There were four groups of a control group, a group cassava starch ratio of 50: 50, groups of cassava starch ratio of 60: 40, and a comparison group of cassava starch 70: 30. The results were dimensional stability of printed materials Alginate without additions were (73.72, 48.77, 30.51), the dimensional stability of the printed material alginate with a ratio of 50: 50 were (74.24, 40.82, 30.76), the dimensional stability of the printed material alginate with a ratio of 60: 30 were ( 75.39, 49.67, 31.57), and the results of dimensional stability alginate ((irrevesible hydrocolloid ) molding material with a ratio of 70: 30 were (76.36, 50.94, 32.86). The conclusion is the addition of Manihot utilisima on standard printed material alginate (irrevesible hydrocolloid) obtained dimensional stability test results that met the standards at a ratio of 50: 50 of ANSI/ADA no.18/1992. Manihot utilisima was one of the appropriate alternatives as a mixture in impression material alginate (irrevesible hydrocolloid).

2016 ◽  
Vol 10 (04) ◽  
pp. 507-511 ◽  
Author(s):  
Hussien Abdalfatah Ismail ◽  
Hani Asfour ◽  
Souaad Abdulelah Shikho

ABSTRACT Objectives: The aim was to evaluate the effect of adding povidone (PVP) iodine powder with different concentrations to irreversible hydrocolloid on both microbiological and dimensional stability. Materials and Methods: Regular set of (alginate) irreversible hydrocolloid was selected as control group. PVP-iodine powder was mixed with the alginate powder at concentrations of 1, 5, 10, 15, and 20% by weight (test groups). All specimens were tested for their antimicrobial effect against Streptococcus mutans and Staphylococcus aureus as well as dimensional stability. Results: The results of test groups showed that concentrations 1, 5, and 10, weight % had little effect against S. mutans and S. aureus microorganisms. While concentrations 15 and 20 weight % had demonstrated greater effect on microbial growth. The mean of dimensional stability in mm of modified alginate with PVP-iodine at 15 and 20 weight % was –0.119 ± 0.255 and –0.035 ± 0.074, respectively. While the mean dimensional stability in mm of unmodified alginate was –0.112 ± 0.176 . The results of dimensional stability showed that 15 and 20 concentrations of test groups adversely affect the dimensional stability. The adverse effect was noticed to be significant in concentration 20%, where as it was nonsignificant in 15% concentration. Conclusion: Modified alginate impression material with 15 weight % PVP-iodine powered give the material, a self-disinfected properties with less deteriorating effect on dimensional stability.


2017 ◽  
Vol 18 (10) ◽  
pp. 887-892 ◽  
Author(s):  
Veena B Benakatti ◽  
Abhijit P Patil ◽  
Jayashee Sajjanar ◽  
Supriya S Shetye ◽  
Ulhas N Amasi ◽  
...  

ABSTRACT Aim This study evaluated the antibacterial activity and dimensional stability of irreversible hydrocolloids mixed with different concentrations of chlorhexidine gluconate instead of water. Materials and methods Experimental specimens (45 specimens) were prepared and allocated into three groups of 15 each. Group I: Impression material mixed with distilled water served as control. Groups II and III were prepared with 0.12 and 0.2% chlorhexidine gluconate solution, respectively. Specimens in each group were subjected to tests for dimensional stability. For antimicrobial activity, 30 specimens were prepared and allocated into three groups of 10 each named as group I (control), group II (0.12% chlorhexidine gluconate), and group III (0.2% chlorhexidine gluconate) similar to specimens for dimensional stability. Statistical analysis was performed using a one-way analysis of variance (ANOVA) and Tukey test. Results Zones of inhibition were observed around test specimens, but not around control specimens; there was a significant intergroup difference in the diameters of the inhibition zones. In the test for dimensional stability, no significant differences were detected among groups, and the accuracy was clinically acceptable. Conclusion Irreversible hydrocolloid impression material mixed with chlorhexidine exhibits varying degrees of antibacterial activity without influencing the dimensional stability of set material. Clinical significance Many contagious diseases can be prevented by practical control of infection in the dental office. Chlorhexidine gluconate, as a mixing liquid, ensures disinfection of impression, and this method of disinfection is more convenient and avoids extra effort as in other disinfection techniques. How to cite this article Benakatti VB, Patil AP, Sajjanar J, Shetye SS, Amasi UN, Patil R. Evaluation of Antibacterial Effect and Dimensional Stability of Self-disinfecting Irreversible Hydrocolloid: An in vitro Study. J Contemp Dent Pract 2017;18(10):887-892.


2005 ◽  
Vol 13 (2) ◽  
pp. 187-192 ◽  
Author(s):  
Ana Cristina Gerent Petry Nunes ◽  
Maria José de Carvalho Rocha

The purpose of this research was to evaluate the diffusion of calcium (Ca+2) and hydroxyl (OH-) ions from materials with a calcium hydroxide base - Ca(OH)2 through the intact roots of deciduous teeth. This diffusion of ions is important for periapical healing. Forty-six deciduous teeth were selected and instrumented to their working length with #40 files. The teeth were washed during cleaning and shaping with a 1% sodium hypochlorite (NaOCl) solution. The canals were dried with paper points. The teeth were divided into 4 groups based on the sealer type, with 10 specimens in each group. A fifth group of 6 teeth without sealer constituted the control group. The materials used as sealers were: Ca(OH)2 paste associated to propylene glycol (CaPE) thickened at the proportion of 2:1 w/v; UFSC (Federal University of Santa Catarina) paste - a mixture of 0.3g of zinc oxide with 0.3g of Ca(OH)2 with 0.2ml of olive oil 1:1 w/w; Vitapex® and Sealapex®. The coronal access was sealed with a glass ionomer after the root had been filled with each sealer. A one-third apical surface and foramen was hard-pressed with Araldite®. The teeth were stored individually in flasks containing saline solution at 37ºC and 100% humidity. The OH- and Ca+2 ions diffusion levels were determined using a pH meter and an atomic absorption spectrometer. Data were collected at 48 hours and at intervals of 7, 30, 45 and 60 days. Statistical analysis was performed using ANOVA to compare groups. In the pH evaluation, the CaPE group presented the largest OH- ions diffusion, which peaked at sixty days (p=0.0309), when compared to the other groups (p<0.0001). In relation to amount of Ca+2 ions released, the CaPE paste showed the best results, followed by the UFSC's paste. These results suggest that the CaPE paste was the material that allowed the highest diffusion of OH- and Ca+2 ions.


Author(s):  
Salah A. Yousief ◽  
Khames T. Alzahrani ◽  
Suha M. Alhuwairini ◽  
Fai Y. Alharbi ◽  
Dalal A. Eissa ◽  
...  

Introduction: Saliva and blood contaminated impressions are often a source of cross contamination between the clinic and dental laboratory. Explicit communication and observance of an infection control protocol for handling of dental impressions must exist among the office staff as well as between office and dental laboratories. Though disinfection of impression is routinely followed, autoclaving elastomeric impression is an effective method of sterilization them. Objectives: The purpose of this study was to evaluate dimensional stability and detail reproduction of a new addition silicon impression material after disinfection. Methods: In this study, a total of twenty impressions for the master model using heat resistant plastic stock trays. The twenty impressions were divided into two groups according to disinfection technique: (Table 2) Group 1: (n=10) Control group, untreated impressions. (C.G) Group 2: (n=10) Impressions were chemically disinfected. (D.G). after all impressions treatment, they were poured with extra hard stone (type IV) to get stone casts. Dimensional accuracy and detail reproduction of the impression material were evaluated indirectly through the recovered improved stone casts from impressions of the master model using the travelling microscope. Results: Cross arch distance (A): Epoxy resin master model cross arch distance measurement (A) was (41.36 mm). 1.1 Measurements of the cross-arch distance of stone casts Control group (C.G): The mean and standard deviation values of distance (A) in stone models obtained from C.G. were 41.553 ± 0.170 mm. Disinfection group (D.G): The mean and standard deviation values of distance (A) in stone models obtained from D.G were 41.368 ± 0.083 mm. ANOVA test showed that there was a statistically difference shrinkage between the groups (P-value = 0.006). 1.2 Measurement of the dimensional changes in the cross-arch distance of the different groups. The mean and standard deviation values of cross arch distance changes in stone models of C.G. were 0.191 ± 0.170 mm. while dimensional changes in stone models obtained from D.G. were 0.006 ± 0.082 mm. Conclusion: The purpose of this study was to evaluate dimensional stability and detail reproduction of a new addition silicon impression material after disinfection. In this study an epoxy resin master model was duplicated from a modified dentate mandibular model. Within the limitations of this study, it could be concluded that Chemical disinfectant of polyvinyl siloxane impression material can be successfully used in making fixed partial dentures.


PRILOZI ◽  
2017 ◽  
Vol 38 (2) ◽  
pp. 131-138 ◽  
Author(s):  
Borjan Naumovski ◽  
Biljana Kapushevska

Abstract A quality-made dental impression is a prerequisite for successful fixed-prosthodontic fabrication and is directly dependent on the dimensional stability, accuracy and flexibility of the elastomeric impression materials, as well as on the appropriately used impression techniques. The purpose of this paper is to provide a literature review of relevant scientific papers which discuss the use of various silicone impression materials, different impression techniques and to evaluate their impact on the dimensional stability and accuracy of the obtained impressions. Scientific papers and studies were selected according to the materials used, the sample size, impression technique, storage time, type of measurements and use of spacer for the period between 2002 and 2016. In the reviewed literature several factors that influence the dimensional stability and accuracy of silicone impression molds, including the choice of the type of viscosity, impression material thickness, impression technique, retention of the impression material on the tray, storage time before the casting, number of castings, hydrophilicity of the material, release of byproducts, contraction after polymerization, thermal contraction and incomplete elastic recovery were presented. The literature review confirmed the lack of standardization of methodologies applied in the research and their great diversity. All findings point to the superiority of the addition silicone compared to the condensation silicone.


2021 ◽  
pp. 105477382110366
Author(s):  
Jing Zhu ◽  
Le-wen Shao ◽  
Jing-yun Yuan ◽  
Liang Zhu ◽  
Can-hua Chen ◽  
...  

This study aims to compare the effectiveness of video and paper materials used for teach-back education on the first insulin injection for patients with diabetes. The study enrolled 110 patients hospitalized for diabetes who had received education on their first insulin injection in the endocrinology department. The patients were divided into an intervention group ( n = 55) and a control group ( n = 55) using convenience sampling. Video materials were employed for the teach-back education of the intervention group, while paper materials were employed for the teach-back education of the control group. We compared cases who answered correctly to the common parts (selection and management of injection devices, selection and rotation of injection sites, proper use of injection angles and pinching, insulin storage, injection-related complications and their prevention, selection of the correct needle length, and safe disposal of needles after use) for the first time, the number of educational sessions and total education duration between the two groups and employed the “ My View on Insulin” questionnaire to survey the two groups before and 28 days after the intervention. The intervention group had a shorter total education duration than the control group, a difference that was statistically significant ( p < .001). The intervention group had more advantages over the control group in terms of rotation education at the injection site ( p < .05). There was no statistically significant difference in the questionnaire scores between the two groups after the intervention ( p > .05); however, both groups scored significantly higher than before the intervention, a difference that was statistically significant ( p < .001). The teach-back method combined with video materials applied for educating patients on their first insulin injection could reduce the education duration by healthcare providers and improve the patients’ psychological insulin resistance. The key to successfully teaching patients to self-administer insulin, and allowing them to master the steps involved, is to focus on “why” rather than “what” to do.


1979 ◽  
Vol 75 (4) ◽  
pp. 438-446 ◽  
Author(s):  
Robert M. Coleman ◽  
John H. Hembree ◽  
Faustin N. Weber

2021 ◽  
Vol 15 (1) ◽  
pp. 658-663
Author(s):  
Noorhayati R. Mohd ◽  
Ros A. Omar ◽  
Enas A. Etajuri

Aims: This study aimed to evaluate and compare the dimensional stability of two elastomeric impression materials, namely polyvinyl siloxane (PVS) and vinyl siloxanether (VSE), subjected to chemical immersion and microwave irradiation for disinfection. Materials and Methods: Sixty discs of PVS and VSE impression materials each were prepared using a stainless-steel test die and ring in accordance with ANSI/ADA Specification No. 19. Twenty discs of each impression material were disinfected by chemical immersion for 10 min; another 20 discs were subjected to dry microwave irradiation for 3 min. The other 20 discs served as a control group. Dimensional stability measurements were then performed using an image analyzer at 20× magnification. The data were analyzed by one-way analysis of variance (α=0.05) and Bonferroni (post hoc) test for multiple comparisons to detect significant differences between the groups. Results: When subjected to microwave irradiation, both PVS and VSE showed dimensional changes, but the changes were within the limit of 1.5% set by ANSI/ADA (P<0.00). VSE showed markedly better results than PVS for both disinfection methods. The immersion disinfection method resulted in a higher average percentage of linear dimensional changes than both the microwave irradiation and the control for VSE and PVS impression materials. Conclusion: VSE exhibited excellent dimensional stability than PVS under both chemical immersion and microwave irradiation. Microwave irradiation using conventional microwave ovens can be used in clinical settings as an alternative to other disinfection techniques because the dimensional changes of the elastomeric impression materials subjected to microwave irradiation have been observed to be within the clinically acceptable limit set by the ANSI/ADA standard.


Marine Drugs ◽  
2022 ◽  
Vol 20 (1) ◽  
pp. 55
Author(s):  
Nurlindah Hamrun ◽  
Bahruddin Talib ◽  
Muhammad Ruslin ◽  
Hasminar Pangeran ◽  
Mochammad Hatta ◽  
...  

This study aimed to investigate the potential use of brown algae Sargassum polycystum as irreversible hydrocolloid (alginate) impression material. Potassium alginate extracted from Sargassum polycystum was prepared in three different compositions (14%, 15%, and 16%) and mixed with other standard components to form an alginate impression material. Prior to that, the purity of potassium alginate was quantified with Fourier Transform Infrared Spectroscopy (FTIR) analysis. As a control material, the alginate impression material from a commercially available product was used. All alginate impression materials were then applied to a die stone model. Dimensional accuracy was measured by calculating the mesiodistal width of incisors in the generated dental cast using a digital caliper 0.01 accuracy (five replications). In addition, to evaluate the dimensional stability, the impression results were poured at four different periods (immediately, 5 min, 10 min, and 15 min). An independent t-test was performed to compare the measurement results with p < 0.05 considered significant. Analytical results confirm that the impression material containing 15% potassium alginate gives the best dimensional accuracy similar to control (p > 0.05). Meanwhile, the optimal dimensional stability was produced in the impression material containing 16% potassium alginate. Our study suggested that brown algae Sargassum polycystum has a promising potential to be used as an alginate impression material in clinical application.


Sign in / Sign up

Export Citation Format

Share Document