Study of the stability of the drug form of Mexicor® by gas chromatography mass spectrometry

Author(s):  
Ivan N. Stan'kov ◽  
Irina D. Derevyagina ◽  
Olga T. Morosova ◽  
Olga V. Serdykova
2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Priyanka Verma ◽  
Atul Bajaj ◽  
R. M. Tripathi ◽  
Sudhir K. Shukla ◽  
Suman Nagpal

Abstract Background Recent advances in the diversified anti-diabetic drugs have appeared in the startling increase in the count of poisoning cases. The epidemics of diabetes mellitus are increasing; hence, the no. of anti-diabetic drug users raised by 42.9%. The use of glimepiride raised to 24%. As the toxicity and drug cases are also escalating with increasing epidemics of diabetes mellitus, a novel gas chromatography-mass spectrometry (GC-MS) method for detecting glimepiride in biological matrices is developed. Results Liquid-liquid extraction method was employed by using 1-butanol: hexane (50:50, v/v) under an alkaline medium, and then back extraction was done via acetic acid. Distinct derivatization techniques were employed for the sample preparation for GC-MS analysis, i.e., silylation and acylation. Derivatization approaches were optimized under different parameters, i.e., reaction temperature and reaction time. N-Methyl-N-(trimethylsilyl) trifluoroacetamide [MSTFA] was found to be the best sound derivatization reagent for the GC-MS analysis of glimepiride. Total ion current (TIC) mode was selected for the monitoring of ions of trimethylsilyl (TMS) derivative of glimepiride with an m/z ratio of 256. Distinct parameters like specificity, carryover, stability, precision, and accuracy were evaluated for validating the identification method. The GC-MS method is found to be linear and illustrated within the range 500 to 2500 ng/ml with the value of R2 (coefficient of determination) at 0.9924. The stability of the extracted and derivatized glimepiride was accessed with regard to processed/extracted sample conditions and autosampler conditions, respectively. Accuracy at each concentration level was within the + 15% of the nominal concentration. Precision (%) for the interday and intraday analysis was found to be in the respectable spectrum. Conclusion Henceforth, the proposed GC-MS method can be employed for the determination of glimepiride in biological matrices.


RSC Advances ◽  
2021 ◽  
Vol 11 (50) ◽  
pp. 31487-31498
Author(s):  
Rokas Sažinas ◽  
Suzanne Zamany Andersen ◽  
Katja Li ◽  
Mattia Saccoccio ◽  
Kevin Krempl ◽  
...  

Lithium-mediated non-aqueous electrochemical ammonia synthesis (LiMEAS) as an efficient and green ammonia production way was studied by GCMS in different organic electrolytes to evaluate the stability of electrochemical systems.


Sign in / Sign up

Export Citation Format

Share Document