scholarly journals Nonthyroidal Illness Syndrome

2021 ◽  
Vol 21 (4) ◽  
pp. 687-700
Author(s):  
Buğra Durmuş ◽  
Hüsniye Başer ◽  
Bekir Çakır
Keyword(s):  
2020 ◽  
Vol 33 (5) ◽  
pp. 653-659
Author(s):  
Jia Song ◽  
Yun Cui ◽  
Chunxia Wang ◽  
Jiaying Dou ◽  
Huijie Miao ◽  
...  

AbstractBackgroundThyroid hormone plays an important role in the adaptation of metabolic function to critically ill. The relationship between thyroid hormone levels and the outcomes of septic shock is still unclear. The aim of this study was to assess the predictive value of thyroid hormone for prognosis in pediatric septic shock.MethodsWe performed a prospective observational study in a pediatric intensive care unit (PICU). Patients with septic shock were enrolled from August 2017 to July 2019. Clinical and laboratory indexes were collected, and thyroid hormone levels were measured on PICU admission.ResultsNinety-three patients who fulfilled the inclusion criteria were enrolled in this study. The incidence of nonthyroidal illness syndrome (NTIS) was 87.09% (81/93) in patients with septic shock. Multivariate logistic regression analysis showed that T4 level was independently associated with in-hospital mortality in patients with septic shock (OR: 0.965, 95% CI: 0.937–0.993, p = 0.017). The area under receiver operating characteristic (ROC) curve (AUC) for T4 was 0.762 (95% CI: 0.655–0.869). The cutoff threshold value of 58.71 nmol/L for T4 offered a sensitivity of 61.54% and a specificity of 85.07%, and patients with T4 < 58.71 nmol/L showed high mortality (60.0%). Moreover, T4 levels were negatively associated with the pediatric risk of mortality III scores (PRISM III), lactate (Lac) level in septic shock children.ConclusionsNonthyroidal illness syndrome is common in pediatric septic shock. T4 is an independent predictor for in-hospital mortality, and patients with T4 < 58.71 nmol/L on PICU admission could be with a risk of hospital mortality.


2012 ◽  
Vol 158 (1) ◽  
pp. 103-104 ◽  
Author(s):  
Chiara Lazzeri ◽  
Andrea Sori ◽  
Claudio Picariello ◽  
Marco Chiostri ◽  
Gian Franco Gensini ◽  
...  

2013 ◽  
Vol 47 (2) ◽  
pp. 153-159 ◽  
Author(s):  
Song Liu ◽  
Jianan Ren ◽  
Yunzhao Zhao ◽  
Gang Han ◽  
Zhiwu Hong ◽  
...  
Keyword(s):  

1996 ◽  
Vol 2 (1) ◽  
pp. 45-52 ◽  
Author(s):  
Inder J. Chopra, MD, FACP

1986 ◽  
pp. 385-389
Author(s):  
F. Kakezono ◽  
S. Yamashita ◽  
N. Yokoyama ◽  
S. Morita ◽  
S. Okamoto ◽  
...  

2012 ◽  
Vol 97 (Suppl 2) ◽  
pp. A276-A276
Author(s):  
M. Neamtu ◽  
L. Dobrota ◽  
M. Neamtu ◽  
C. B. Neamtu ◽  
F. Diac
Keyword(s):  

1993 ◽  
Vol 39 (8) ◽  
pp. 1668-1674 ◽  
Author(s):  
R Docter ◽  
H van Toor ◽  
E P Krenning ◽  
M de Jong ◽  
G Hennemann

Abstract Three methods for estimating free thyroxine (FT4) in serum were studied: equilibrium dialysis, the SPAC-ET FT4 radioimmunoassay kit, and the Amerlite MAB FT4 luminometric assay. Serum samples from 10 subjects with above-normal thyroxine-binding globulin (TBG), 6 with low TBG, 30 with familial dysalbuminemic hyperthyroxinemia (FDH), 13 with nonesterified fatty acids (NEFA) concentrations in serum &gt; 1.0 mmol/L, and 178 patients with various degrees of nonthyroidal illness (NTI) were measured and compared with samples from 42 euthyroid blood donors. The Amerlite MAB FT4 assay compared well with equilibrium dialysis, whereas the SPAC-ET assay averaged 40% lower. All three assays were not influenced by changes in TBG and showed no or only little changes in the presence of NEFA. Mean FT4 values in the FDH samples were somewhat higher than in controls when measured with the SPAC-ET assay, about equal with equilibrium dialysis, and somewhat below the mean control value with the Amerlite MAB FT4 assay, although individual results were within the control reference range. In NTI patients, no FT4 values were below the control reference range by the Amerlite MAB FT4 assay, 4 of 178 were below this range by equilibrium dialysis, and 1 of 178 was below this range by the SPAC-ET assay. In all assays a large proportion of the NTI samples showed FT4 values above the control reference range, a result that will interfere with the efficacy of these assays for assessing thyroid function in NTI patients.


1987 ◽  
Vol 33 (4) ◽  
pp. 566-569 ◽  
Author(s):  
R John ◽  
P E Evans ◽  
M F Scanlon ◽  
R Hall

Abstract Using a two-site immunoradiometric assay, we measured concentrations of thyrotropin (TSH) in serum of 134 clinically euthyroid subjects, 93 patients with nonthyroidal illness, and 80 patients who were being treated with various drugs. Abnormal concentrations of TSH, free thyroxin, and free triiodothyronine, respectively, were recorded in serum of three (3.2%), 19 (20.4%), and 37 (39.8%) of the patients with nonthyroidal illness and in three (3.8%), five (6.3%), and 10 (12.5%) of the patients taking drugs. TSH could be detected in all patients' serum samples. We conclude that, for most patients without thyroid disease, a basal (i.e., unstimulated) measurement of their TSH concentration in serum will indicate their thyroid status more reliably than will assay of free thyroxin or free triiodothyronine.


Sign in / Sign up

Export Citation Format

Share Document