Investigations of corrosion behaviour of SnSb12Cu6Pb alloy in 0.1M H2SO4 and 0.5M NaCl solution

Author(s):  
J. Hrabia-Wiśnios ◽  
B. Leszczyńska-Madej ◽  
R. Kowalik

Purpose: The results presented the microstructure and corrosive behavior of SnSb12Cu6Pb alloy (B82) in H2SO4 aqueous solution and NaCl aqueous solution. Design/methodology/approach: The electrochemical corrosion has been investigated in two different aqueous solutions: 0.1M sulfuric acid (H2SO4) and 0.5M sodium chloride (NaCl) solution measuring of potential changes relative to immersion time and conducting mass loss test. Microscopic investigations before and after corrosion tests were made using scanning electron microscopy. Findings: The obtained results indicate very good corrosion resistance of the alloy tested in NaCl solution. Corrosion progresses faster in a sulfuric acid aqueous solution compared to sodium chloride aqueous solution. Also, it was found that the dominant mechanism of corrosion degradation in both solutions is selective corrosion which is a particularly undesirable type of corrosion because it involves the loss of one alloying component and the formation of porous structure on the alloy surface. Research limitations/implications: The aqueous solutions used in this study are not a natural working environment of the bearing. However, a comparison of acidic and neutral solutions allows explaining the corrosion behavior of tin babbitts due to contaminants of oil lubricants. Further research should be conducted in more aggressive environments characteristic of industrial conditions. Practical implications: One of the important properties of bearing alloys are corrosion resistance. Corrosion properties are extremely important for the transport and storage of metallic components before they are used. Also, the working environment can have a destructive effect on the properties of the materials used. Industry environment, aging stagnant oil, and some acids may lead to selective corrosion of the tin, copper, lead, or antimony components and leaving a rough and weakened the babbitt surface. Electrochemical corrosion can contribute to the acceleration of bearing wear and consequent to bearing damage. Originality/value: Studies of the corrosion of tin-babbitt bearings are not extensive in the literature due to rare tin corrosion. This study could be an important complement to knowledge about the corrosion behavior of tin-based bearing alloys.

Materials ◽  
2020 ◽  
Vol 13 (22) ◽  
pp. 5157
Author(s):  
Chun-Huei Tsau ◽  
Rong-Wei Hsiao ◽  
Tien-Yu Chien

This paper investigates the effects of Ta content on the microstructures, hardness and corrosion behavior of as-cast CoCrFeNiTax alloys. The results indicate that the addition of Ta can change the microstructures of these alloys to dual-phased structures (FCC + HCP), as well as increasing their hardness. This study uses constant galvanostatic/potentiometric methods to measure the polarization curves of CoCrFeNiTa0.1, CoCrFeNiTa0.3 and CoCrFeNiTa0.5 alloys in deaerated 1 M sodium chloride solution at different temperatures. Electrochemical impedance spectroscopy is also used to analyze these alloys in sodium chloride solution. The results indicate that the CoCrFeNiTa0.5 alloy has a eutectic structure and the highest hardness. Furthermore, although the CoCrFeNiTa0.5 alloy has the best corrosion resistance, the CoCrFeNiTa0.3 alloy has the best pitting resistance among these alloys.


2012 ◽  
Vol 581-582 ◽  
pp. 1102-1105 ◽  
Author(s):  
Nan Lu ◽  
Yi Yao ◽  
Kun Ming Gu ◽  
Zhao Long Lu ◽  
Hai Peng Yang ◽  
...  

To get basic information on corrosion of metals under sewage sludge environment, in this work, the corrosion behavior of SAE1045 steel under SiO2 gel with 3 wt% NaCl was investigated by electrochemical polarization method. The results show that the self-orrosion potential of the steel move to more negative value in SiO2 gel comparing to those in aqueous solution. It was found by SEM and EDX measurements that, after 15 days of wilhelmy test in SiO2 gel, a dense covering layer containing a lot of Si appeared on the surface of steel, which was attributed to the difference of corrosion behavior for the metal under SiO2 gel and aqueous solution.


CORROSION ◽  
2010 ◽  
Vol 66 (11) ◽  
pp. 116002-116002-4 ◽  
Author(s):  
H.-G. Kim ◽  
H. J. Jang

Abstract The corrosion behavior of amorphous Co69Fe4.5Cr1.5Si10B15 alloy ribbon was investigated using potentiodynamic polarization tests in 0.001 M sulfuric acid (H2SO4) solution, 0.01 M ∼ 0.09 M sodium chloride (NaCl) solution, and solutions at pH levels from 3 to 13 made by mixing hydrochloric acid (HCl) and sodium hydroxide (NaOH). The corrosion potential decreased and the corrosion rate increased with an increase in solution temperature. The influence of solution temperature was more significant in H2SO4 solution than in NaCl solution. The amorphous Co69Fe4.5Cr1.5Si10B15 alloy ribbon showed passivity in solution with a pH higher than 7, and the corrosion rate was minimized at a pH of 9.


Materials ◽  
2021 ◽  
Vol 14 (10) ◽  
pp. 2549
Author(s):  
Wenchao Yang ◽  
Jun Mao ◽  
Yueyuan Ma ◽  
Shuyuan Yu ◽  
Hongping He ◽  
...  

Electrochemical corrosion behavior of ternary tin-zinc-yttrium (Sn-9Zn-xY) solder alloys were investigated in aerated 3.5 wt.% NaCl solution using potentiodynamic polarization techniques, and the microstructure evolution was obtained by scanning electron microscope (SEM). Eight different compositions of Sn-9Zn-xY (x = 0, 0.02, 0.04, 0.06, 0.08, 0.10, 0.20, and 0.30 wt.%) were compared by melting. The experimental results show that when the content of Y reached 0.06 wt.%, the grain size of Zn-rich phase became the smallest and the effect of grain refinement was the best, but there was no significant effect on the melting point. With the increases of Y content, the spreading ratio first increased and then decreased. When the content of Y was 0.06 wt.%, the Sn-9Zn-0.06Y solder alloy had the best wettability on the Cu substrate, which was increased by approximately 20% compared with Sn-9Zn. Besides, the electrochemical corrosion experimental shows that the Y can improve the corrosion resistance of Sn-9Zn system in 3.5 wt.% NaCl solution, and the corrosion resistance of the alloy is better when the amount of Y added is larger within 0.02–0.30 wt.%. Overall considering all performances, the optimal performance can be obtained when the addition amount of Y is 0.06.


2021 ◽  
Vol 2 (1) ◽  
pp. 61-77
Author(s):  
Hamid Reza Jafari ◽  
Ali Davoodi ◽  
Saman Hosseinpour

In this work, the corrosion behavior and surface reactivity of as-cast and heat-treated nickel aluminum bronze casting alloy (UNS C95800) in 3.5 wt% NaCl solution is investigated under stagnant and flow conditions. Increasing flow rate conditions are simulated using a rotating disk electrode from 0 to 9000 revolutions per minute (rpm). Optical micrographs confirm the decrease in the phase fraction of corrosion-sensitive β phase in the microstructure of C95800 after annealing, which, in turn, enhances the corrosion resistance of the alloy. Electrochemical studies including open circuit potentiometry, potentiodynamic polarization, and electrochemical impedance spectroscopy are performed to assess the effect of flow rate and heat treatment on the corrosion of samples at 25 and 40 °C in 3.5 wt% NaCl solution. For both as-cast and heat-treated samples, increasing the flow rate (i.e., electrode rotating rate) linearly reduces the corrosion resistance, indicating that the metal dissolution rate is significantly affected by hydrodynamic flow. Increasing the solution temperature negatively impacts the corrosion behavior of the as-cast and heat-treated samples at all flow conditions.


2013 ◽  
Vol 83 (5) ◽  
pp. 864-869 ◽  
Author(s):  
Elisa J. Kassab ◽  
José Ponciano Gomes

ABSTRACT Objective: To assess the influence of fluoride concentration on the corrosion behavior of nickel titanium (NiTi) superelastic wire and to compare the corrosion resistance of NiTi with that of beta titanium alloy in physiological solution with and without addition of fluoride. Materials and Methods: NiTi corrosion resistance was investigated through electrochemical impedance spectroscopy and anodic polarization in sodium chloride (NaCl 0.15 M) with and without addition of 0.02 M sodium fluoride (NaF), and the results were compared with those associated with beta titanium. The influence of fluoride concentration on NiTi corrosion behavior was assessed in NaCl (0.15 M) with and without 0.02, 0.04, 0.05, 0.07, and 0.12 M NaF solution. Galvanic corrosion between NiTi and beta titanium were investigated. All samples were characterized by scanning electron microscopy. Results: Polarization resistance decreased when NaF concentration was increased, and, depending on NaF concentration, NiTi can suffer localized or generalized corrosion. In NaCl solution with 0.02 M NaF, NiTi suffer localized corrosion, while beta titanium alloys remained passive. Current values near zero were observed by galvanic coupling of NiTi and beta titanium. Conclusions: There is a decrease in NiTi corrosion resistance in the presence of fluoride. The corrosion behavior of NiTi alloy depends on fluoride concentration. When 0.02 and 0.04 M of NaF were added to the NaCl solution, NiTi presented localized corrosion. When NaF concentration increased to 0.05, 0.07, and 0.12 M, the alloy presented general corrosion. NiTi corrosion resistance behavior is lower than that of beta titanium. Galvanic coupling of these alloys does not increase corrosion rates.


2021 ◽  
Vol 1016 ◽  
pp. 997-1002
Author(s):  
Hikaru Nagata ◽  
Masa Ono ◽  
Yasuyuki Miyazawa ◽  
Yuji Hayashi ◽  
Yoshio Bizen

To clarify the effect of the acid solution type on corrosion resistance, the corrosion behavior of stainless steel brazed joints in HCl aqueous solution was evaluated through electrochemical measurements. Anodic polarization curves of a ferritic stainless-steel base metal, Ni-based brazing filler metals, and a brazed joint were recorded. In addition, in situ observations were conducted to observe the corrosion behavior of each structure of the brazed joint. Corrosion potentials of the brazing filler metal were lower than that of the base metal. In situ observations of the brazed joint revealed the order of corrosion in aqueous hydrochloric acid. According to the electrochemical measurements, under an actual corrosive environment, the brazing filler metal can function as an anode and selectively corrode. In addition, the anodic polarization curve of the brazed joint showed values between those of the polarization curves of the brazing filler metal and the base metal, indicating that the corrosion resistance could be electrochemically evaluated in HCl aqueous solution.


1970 ◽  
Vol 25 ◽  
pp. 53-61
Author(s):  
Minu Basnet ◽  
Jagadeesh Bhattarai

The corrosion behavior of the sputter-deposited nanocrystalline W-Cr alloys wasstudied in 0.5 M NaCl and alkaline 1 M NaOH solutions at 25°C, open to air usingimmersion tests and electrochemical measurements. Chromium metal acts synergisticallywith tungsten in enhancing the corrosion resistance of the sputter-deposited W-Cr alloys soas to show higher corrosion resistance than those of alloy-constituting elements in both 0.5M NaCl and 1 M NaOH solutions. In particular, the nanocrystalline W-Cr alloys containing25-91 at% chromium showed about one order of magnitude lower corrosion rates (that is,about 1-2 × 10-3 mm.y-1) than those of tungsten and chromium metals even for prolongedimmersion in 0.5 M NaCl solution at 25°C. On the other hand, the corrosion rate of thesputter-deposited W-Cr alloys containing 25-75 at % chromium was decreased significantlywith increasing chromium content and showed lowest corrosion rates (that is, 1.5-2.0 × 10-3 mm.y-1) after immersed for prolonged immersion in 1 M NaOH solution. The corrosion ratesof these nanocrystalline W-(25-75)Cr alloys are nearly two orders of magnitude lower thanthat of tungsten and more than one order of magnitude lower corrosion rate than that ofsputter-deposited chromium metal in 1 M NaOH solution. The corrosion-resistant of all theexamined sputter-deposited W-Cr alloys in 0.5 M NaCl solution is higher than in alkaline 1M NaOH solution at 25°C. Open circuit potentials of all the examined W-Cr alloys areshifted to more noble direction with increasing the chromium content in the alloys afterimmersion for 72 h in both 0.5 M NaCl and 1 M NaOH solutions at 25°C, open to air.Keywords: Sputter deposition, nanocrystalline W-Cr alloys, corrosion test, electrochemicalmeasurement, NaCl and NaOH solutions.DOI:  10.3126/jncs.v25i0.3300Journal of Nepal Chemical Society Volume 25, 2010 pp 53-61


Sign in / Sign up

Export Citation Format

Share Document