Analysis of False-Negative Diagnoses on Endoscopic Brush Cytology of Biliary and Pancreatic Duct Strictures

2000 ◽  
Vol 124 (3) ◽  
pp. 387-392 ◽  
Author(s):  
Roberto Logrono ◽  
Daniel F. Kurtycz ◽  
Claudia P. Molina ◽  
Vipul A. Trivedi ◽  
Jick Y. Wong ◽  
...  

Abstract Context.—Endoscopic brush cytology is a valuable technique for the diagnosis of pancreatobiliary malignancy. Despite its widespread use, the sensitivity of this method has been reported as approximately 50%. The specificity is usually higher than 95%. Few reports have systematically analyzed the reasons for this relatively low sensitivity. Objectives.—To determine the rate and reasons for false-negative diagnoses in endoscopic brushing cytology of biliary and pancreatic ducts based on the results of sensitivity, specificity, accuracy, and positive and negative predictive values. Design.—Retrospective analysis of laboratory data and slide review of false-negative cases. Setting.—Two tertiary care state university hospitals. Patients.—A total of 183 pancreatobiliary brushing specimens obtained from patients undergoing endoscopic retrograde cholangiopancreatography for biliary or pancreatic duct disease for a 4- to 5-year period. Intervention.—Endoscopic retrograde cholangiopancreatography brushings. Main Outcome Measures.—Determination of sensitivity, specificity, accuracy, and positive and negative predictive values. Analysis of false-negative results. Results.—The sensitivity, specificity, accuracy, and positive and negative predictive values, overall, were 48%, 98%, 79%, 92%, and 76%, respectively. Sampling error was a major cause of false-negative diagnoses (67%), followed by interpretive (17%) and technical errors (17%). Conclusions.—Improvements in sensitivity and diagnostic accuracy for cancer of the pancreatobiliary tract can be achieved by optimizing slide preparatory techniques. Also, enhancement of the cytologist's diagnostic skills enables the identification of the morphologic features of premalignant lesions. Repeat brushings are indicated for suspicious or negative results not consistent with the clinical or radiologic findings.

2020 ◽  
pp. 028418512094491
Author(s):  
Tiezheng Wang ◽  
Hengtao Qi ◽  
Kai Rong ◽  
Shuqian Zhang ◽  
Shougang Bao ◽  
...  

Background Patients with talocalcaneal coalitions (TCC) often undergo computed tomography (CT). However, ultrasonography diagnosis of TCC has been seldom done according to the literature. Purpose To investigate the accuracy of ultrasonography in diagnosing TCC compared to CT. Material and Methods Ninety-seven consecutive patients with a clinical suspicion of TCC were included. Ultrasonography was used to assess the classification and complication of TCC. The main sonographic criteria for a positive diagnosis in cases of osseous coalition were the joint space between the medial surface of talar head and the underlying sustentaculum tali of calcaneus disappearing and being replaced by a continuous hyperechoic bony structure. In cases of fibrous coalition, ultrasonography revealed a reduced space of the joint associated with an irregular, angular appearance of its outline and hypoechoic fibrous tissue inside. These data were compared with CT findings. κ statistic was applied to determine the level of agreement. The sensitivity, specificity, positive and negative predictive values, accuracy, and Youden index of ultrasonography as a diagnostic method were assessed. Results Ultrasonography findings were positive in 20 of 97 patients with a clinical suspicion of TCC. The diagnosis was confirmed by CT in 21 patients. There were one false-positive result and two false-negative results by ultrasonography. The κ value was 0.907. The sensitivity, specificity, positive and negative predictive values, accuracy, and Youden index of ultrasonography were 90.5%, 98.7%, 95.0%, 97.4%, 96.9%, and 0.892, respectively. Conclusion Ultrasonography could be a reliable, accurate, and non-radioactive diagnostic imaging method in diagnosis of patients with suspected TCC.


2017 ◽  
Vol 38 (06) ◽  
pp. 619-625 ◽  
Author(s):  
Lukas Beyer ◽  
Florian Wassermann ◽  
Benedikt Pregler ◽  
Katharina Michalik ◽  
Janine Rennert ◽  
...  

Abstract Aim The purpose of this study was to compare contrast-enhanced ultrasound (CEUS), magnetic resonance imaging (MRI) using liver-specific contrast agent and a combination of both for the characterization of focal liver lesions (FLL). Methods 83 patients with both benign and malignant liver lesions were examined using CEUS and MRI after the intravenous administration of liver-specific contrast media. All patients had inconclusive results from prior imaging examinations. Histopathological specimens could be obtained in 53 patients. Ultrasound was performed using a multi-frequency curved probe (1 – 6 MHz) after the injection of 1 – 2.4 ml ultrasound contrast media. The sensitivity, specificity, positive predictive value and negative predictive value of CEUS, MRI and a combination of both (CEUS + MRI) were compared. Results The sensitivity, specificity, positive and negative predictive values regarding lesion classification were 90.9 %, 70.6 %, 92.3 % and 66.6 %, respectively, for CEUS; 90.9 %, 82.4 %, 95.2 % and 70.0 %, respectively, for MRI; and 96.9 %, 70.6 %, 92.7 % and 85.7 % respectively, for CEUS + MRI. There were no statistically significant differences. 6 malignant lesions were missed using CEUS or MRI alone (false negatives). The use of both modalities combined reduced the false-negative results to 2. Conclusion CEUS and MRI with liver-specific contrast media are very reliable and of equal informative value in the characterization of focal liver lesions. The number of false-negative results can be decreased using a combination of the two methods.


2020 ◽  
Vol 3 (Supplement_1) ◽  
pp. 150-151
Author(s):  
S A Taylor ◽  
A W Bak ◽  
T Lin ◽  
F Jowhari ◽  
M Savard ◽  
...  

Abstract Background Pancreatic and biliary cancer can be difficult to definitively diagnose, and tissue diagnosis defines clinical management in both early and late disease. The majority of patients with pancreaticobiliary malignancy present with late disease and only 30% have resectable tumours, contributing to poor prognosis and outcome. Endoscopic retrograde cholangiopancreatography (ERCP) is a mainstay for diagnosing and treating conditions of the bile and pancreatic duct. Aims This study aimed to provide data on the diagnostic performance of ERCP utilizing conventional methods for tissue acquisition particularly in the setting of an indeterminate stricture. In particular, this was a quality assurance review to determine our centre’s baseline performance as a reference so new methods of tissue acquisition such as SpyglassTM can be benchmarked against. Methods In a tertiary care hospital, 3723 ERCP procedures were performed between 2013 and 2017. Demographic and clinical information was retrospectively collected. Demographic and clinical information was collected. Three ERCP techniques of tissue sampling were analyzed: brushing alone (BiA), biopsy alone (BrA), and brushing and biopsy dual-modality approach (BrBi). The diagnostic performances (sensitivity, specificity, and accuracy) were calculated with data from post-sampling clinical reports, surgical pathological reports, and diagnostic imaging reports. Results 222 patients (285 ERCP procedure) met the study criteria and received fluoroscopy-guided ERCP sampling with cytology brushing and/or tissue biopsies. 36 (13%) patients had BiA, 85 (29%) patients had BrA, and 164 (58%) patients had BrBi. The sensitivities, specificities, and accuracies of the three sampling techniques respectively were: 56%, 93%, and 85% for BiA; 73%, 96%, and 83% for BrA; and 79%, 94%, and 86% for BrBi. Conclusions Our retrospective analysis of fluoroscopic-guided tissue acquisition shows accuracy as high as current published data on direct visualization cholangiosopy guided techniques. A prospective study looking not only at clinical yield but a cost analysis should be put in place prior to a commitment to purchase new equipment such as the SpyglassTM. Funding Agencies None


PLoS ONE ◽  
2021 ◽  
Vol 16 (9) ◽  
pp. e0257452
Author(s):  
Norihito Kaku ◽  
Fumitaka Nishimura ◽  
Yui Shigeishi ◽  
Rina Tachiki ◽  
Hironori Sakai ◽  
...  

Objectives A few studies on antibody testing have focused on asymptomatic or mild coronavirus disease 2019 (COVID-19) patients with low initial anti-severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antibody responses. Anti-SARS-CoV-2 antibody-testing performance was evaluated using blood samples from asymptomatic or mild COVID-19 patients. Methods Blood samples were collected from 143 COVID-19 patients during an outbreak on a cruise ship 3 weeks after diagnosis. Simultaneously, a follow-up SARS-CoV-2 genetic test was performed. Samples stored before the COVID-19 pandemic were also used to evaluate the lateral flow immunochromatographic assay (LFA) and electrochemiluminescence immunoassay (ECLIA). Titers of anti-SARS-CoV-2 IgM and IgG antibodies against the nucleocapsid and spike proteins were measured using the enzyme-linked immunosorbent assay to confirm which antibodies were influenced on LFA- and ECLIA- false-negative result in crew-member samples. Results Sensitivity, specificity, positive-predictive, and negative-predictive values of LFA-detected IgM antibodies were 0.231, 1.000, 1.000, and 0.613, respectively; those of LFA-detected IgG antibodies were 0.483, 0.989, 0.972, and 0.601, respectively; and those of ECLIA-detected total antibodies were 0.783, 1.000, 1.000, and 0.848, respectively. All antibody titers measured using ELISA were significantly lower in blood samples with negative results than in those with positive results in both LFA and ECLIA. In the patients with negative results from the follow-up genetic testing, IgM-, IgG-, and total-antibody positivity rates were 22.9%, 47.6%, and 72.4%, respectively. Conclusions These findings suggest that anti-SARS-CoV-2 antibody testing has lower performance in asymptomatic or mild COVID-19 patients than required in the guidelines.


1998 ◽  
Vol 26 (5) ◽  
pp. 610-613 ◽  
Author(s):  
Stephen J. O'Brien ◽  
Michael J. Pagnani ◽  
Stephen Fealy ◽  
Scott R. McGlynn ◽  
Joseph B. Wilson

Labral tears and acromioclavicular joint abnormalities were differentiated on physical examination using a new diagnostic test. The standing patient forward flexed the arm to 90° with the elbow in full extension and then adducted the arm 10° to 15° medial to the sagittal plane of the body and internally rotated it so that the thumb pointed downward. The examiner, standing behind the patient, applied a uniform downward force to the arm. With the arm in the same position, the palm was then fully supinated and the maneuver was repeated. The test was considered positive if pain was elicited during the first maneuver, and was reduced or eliminated with the second. Pain localized to the acromioclavicular joint or “on top” was diagnostic of acromioclavicular joint abnormality, whereas pain or painful clicking described as “inside” the shoulder was considered indicative of labral abnormality. A prospective study was performed on 318 patients to determine the sensitivity, specificity, and positive and negative predictive values of the test. Fifty-three of 56 patients whose preoperative examinations indicated a labral tear had confirmed labral tears that were repaired at surgery. Fifty-five of 62 patients who had pain in the acromioclavicular joint and whose preoperative examinations indicated abnormalilties in the joint had positive clinical, operative, or radiographic evidence of acromioclavicular injury. There were no false-negative results in either group.


2017 ◽  
Vol 26 (2) ◽  
pp. 165-170 ◽  
Author(s):  
Pedro Pereira ◽  
Armando Peixoto ◽  
Patrícia Andrade ◽  
Guilherme Macedo

Smaller endoscopes and catheters have been developed that permit direct visualization of the bile and pancreatic ducts (cholangioscopy and pancreatoscopy, respectively). These endoscopes and catheters are passed through the working channel of a standard therapeutic duodenoscope during endoscopic retrograde cholangiopancreatography (ERCP). The SpyGlass Direct Visualization System (Boston Scientific Corp, Natick, MA, USA) is currently the most widely used and studied device. Cholangioscopy with intraductal lithotripsy has become an established modality in the treatment of difficult biliary lithiasis. When used in the evaluation of indeterminate biliary strictures by experienced endoscopists in recognizing intraductal pathology, it increases the diagnostic yield of tissue sampling. Pancreatoscopy is complementary to other imaging modalities in the evaluation of intraductal papillary mucinous neoplasms of the pancreas and is emerging as a sole or adjunctive therapy to extracorporeal shock wave lithotripsy for the treatment of main pancreatic duct stones. It remains investigational in the diagnosis of pancreatic adenocarcinoma. Complications specific to the performance of cholangiopancreatoscopy include cholangitis, which is related to intraductal fluid irrigation.Abbreviations: EHL: Electrohydraulic lithotripsy; ERCP: Endoscopic retrograde cholangiopancreatography; ESWL: Extracorporeal lithotripsy by shock waves; ET: Endoscopic therapy; EUS: Endoscopic ultrasound; IPMN: intraductal papillary mucinous neoplasm; LL: Laser lithotripsy; MDCT: Multi-detector computed conventional tomography; MPD: Main pancreatic duct; MRCP: Magnetic resonance cholangiopancreatography; MRI: Magnetic resonance imaging; POCPS: Peroral cholangiopancreatoscopy; PSC: Primary sclerosing cholangitis  


2020 ◽  
Vol 41 (4) ◽  
pp. 240-247
Author(s):  
Lei Yang ◽  
Qingtao Zhao ◽  
Shuyu Wang

Background: Serum periostin has been proposed as a noninvasive biomarker for asthma diagnosis and management. However, its accuracy for the diagnosis of asthma in different populations is not completely clear. Methods: This meta-analysis aimed to evaluate the diagnostic accuracy of periostin level in the clinical determination of asthma. Several medical literature data bases were searched for relevant studies through December 1, 2019. The numbers of patients with true-positive, false-positive, false-negative, and true-negative results for the periostin level were extracted from each individual study. We assessed the risk of bias by using Quality Assessment of Diagnostic Accuracy Studies 2. We used the meta-analysis to produce summary estimates of accuracy. Results: In total, nine studies with 1757 subjects met the inclusion criteria. The pooled estimates of sensitivity, specificity, and diagnostic odds ratios for the detection of asthma were 0.58 (95% confidence interval [CI], 0.38‐0.76), 0.86 (95% CI, 0.74‐0.93), and 8.28 (95% CI, 3.67‐18.68), respectively. The area under the summary receiver operating characteristic curve was 0.82 (95% CI, 0.79‐0.85). And significant publication bias was found in this meta‐analysis (p = 0.39). Conclusion: Serum periostin may be used for the diagnosis of asthma, with moderate diagnostic accuracy.