The Optimum Number and Types of Plasma Samples Necessary for an Accurate Activated Partial Thromboplastin Time–Based Heparin Therapeutic Range

2013 ◽  
Vol 137 (1) ◽  
pp. 77-82 ◽  
Author(s):  
Richard A. Marlar ◽  
Jana Gausman

Context.—Monitoring of unfractionated heparin therapy by activated partial thromboplastin time (aPTT) using the ex vivo method for determining the aPTT-based heparin therapeutic range (HTR) is the standard of practice. Many intrinsic and extrinsic factors influence its accuracy. Objective.—To investigate the optimum number and types of samples acceptable for an accurate ex vivo HTR determination. Design.—Values from patients receiving unfractionated heparin are used to determine the HTR by published guidelines. The number and types of samples are changed to investigate the effect on HTR parameters. Results.—Absolute minimum number of samples for an accurate HTR is 20, with fewer than 10% of the samples from the same patient or 50% of the samples with international normalized ratio of 1.3 to 1.5. Conclusions.—The ex vivo HTR method is the best protocol currently available; however, the number of samples used affects its accuracy. The optimum number of samples is 30 or more but the absolute minimum number is 20. In addition, limitation of specific sample types also affects the HTR parameters. An inaccurate HTR may be calculated if inappropriate sample number or types of samples are used.

Blood ◽  
2008 ◽  
Vol 112 (11) ◽  
pp. 435-435
Author(s):  
Adam Cuker ◽  
Beverly Ptashkin ◽  
Barbara A. Konkle ◽  
Steven W. Pipe ◽  
Herbert C. Whinna ◽  
...  

Abstract Although the activated partial thromboplastin time (aPTT) remains the most widely used method for monitoring unfractionated heparin (UFH) therapy, it is affected by a number of preanalytic, analytic, and biological variables, which undermine both its accuracy and precision. In an effort to improve the accuracy and precision of laboratory monitoring of UFH, the College of American Pathologists (CAP) and the American College of Chest Physicians (ACCP) have issued guidelines recommending that the therapeutic range of the aPTT be defined in each laboratory through correlation with a direct measurement of heparin activity such as the factor Xa inhibition assay (anti-FXa). Whether and to what extent this approach enhances the precision of UFH monitoring has not been reported. We conducted a cross-validation study among 4 CAP-accredited coagulation laboratories to assess the interlaboratory precision of the anti-FXa-correlation method. An aPTT and anti-FXa were performed in each laboratory on plasma samples from 44 inpatients receiving UFH. Interlaboratory precision of the anti-FXa-correlation method was compared to that of the traditional 1.5–2.5 times the upper limit of normal (ULN) method for defining the therapeutic aPTT range. Modest to poor intralaboratory correlation between the aPTT and anti-FXa was observed in each of the 4 laboratories. The coefficients of determination (R2) ranged from 0.1962 to 0.6964. In accordance with CAP guidelines, the anti-FXa-derived therapeutic aPTT range was defined by linear regression corresponding to a range of anti-FXa activity of 0.3 – 0.7 units/ml. In each laboratory, the range defined by this method was broader than that defined using the ULN method. In 3 of the laboratories, the therapeutic range defined by the anti-FXa-correlation method extended more than 20 seconds beyond the upper limit of the therapeutic range defined by the ULN approach. Based on the laboratory-specific therapeutic ranges defined by both methods, samples were segregated into therapeutic category [i.e. below therapeutic (BT), therapeutic (T), or above therapeutic (AT)]. Using the ULN method, there was agreement among all 4 laboratories regarding the therapeutic category in 22 (50%) samples, whereas consensus was achieved in only 7 (16%) samples with the anti-FXa-correlation method. Furthermore, 3 (7%) samples were simultaneously determined to be BT and AT in different laboratories by the anti-FXa-correlation method, suggesting that the dose of UFH might be increased in one center and decreased in another for the same patient encounter. This striking discrepancy was not observed with the ULN method. In conclusion, the anti-FXa-correlation method for defining the therapeutic range of the aPTT does not enhance the interlaboratory precision of UFH laboratory monitoring and may be inferior to the ULN method in this regard. Clinical studies are needed to assess the impact of these findings on patient safety.


1996 ◽  
Vol 75 (05) ◽  
pp. 734-739 ◽  
Author(s):  
S Kitchen ◽  
F E Preston

SummaryThe activated partial thromboplastin time (APTT) is the most commonly used test for laboratory monitoring of unfractionated heparin therapy. Since there are differences between APTT reagents in respect of responsiveness to heparin the widely used therapeutic range of 1.5-2.5 (APTT ratios) may not be appropriate for all reagents.The aim of this study was to assess the relationship between 6 different APTT reagents using a manual technique, 2 of these reagents used in combination with a coagulometer, a heparin assay by protamine titration and a chromogenic anti-Xa assay. Samples from 42 patients treated with unfractionated heparin for thromboembolic disease were studied, 12 of whom were receiving warfarin therapy with International Normalised Ratios (INR) of >1.3.For normal subjects, APTT results were highly dependent on the method used and statistically significant differences were noted. The ratio of patient to mean normal APTT was calculated for each APTT method. When 30 samples from heparinised patients (with INRs of <1.3) were analysed manually, the APTT ranges equivalent to 0.2-0.4 u/ml heparin by protamine titration (by regression analysis) were 1.6-1.9 for Boehringer reagent (the least responsive) up to 2.2-2.9 for Instrumentation Laboratory reagent (the most responsive). The concentration of heparin associated on average with APTT ratios of 1.5-2.5 varied approximately twofold to threefold between reagents.


2001 ◽  
Vol 161 (3) ◽  
pp. 385 ◽  
Author(s):  
Shannon M. Bates ◽  
Jeffrey I. Weitz ◽  
Marilyn Johnston ◽  
Jack Hirsh ◽  
Jeffrey S. Ginsberg

2016 ◽  
Vol 24 (1) ◽  
pp. 164-171 ◽  
Author(s):  
Karlien L. M. Coene ◽  
Fedde van der Graaf ◽  
Daan van de Kerkhof

Background: Protocolled treatment with unfractionated heparin (UFH) is a subject of ongoing debate. Even though international guidelines prescribe calibration of the activated partial thromboplastin time (aPTT) to 0.3 to 0.7 U/mL anti-Xa activity to establish an UFH therapeutic range, evidence for this approach remains scarce. In this study, we evaluated different strategies to delineate the UFH therapeutic range and analyzed the effects on patient therapeutic classification. Methods: In 109 patient samples, the aPTT was measured with 2 different reagents, both of which used mechanical clot detection. The UFH therapeutic range was determined using 3 previously described methods: calibration of the aPTT to 0.3 to 0.7 U/mL anti-Xa activity, application of 1.5 to 2.5 times the control aPTT, or using 0.3 to 0.7 U/mL anti-Xa activity directly. We also applied the UFH therapeutic range of a second hospital to our patient population. Results: Application of the guideline-prescribed anti-Xa calibration method would result in patients receiving increased UFH dosage in comparison to our previous UFH nomogram. Between-method and between-laboratory variations in aPTT and anti-Xa activity assays are a likely cause of these discrepancies. Additionally, we show that individual patient characteristics, such as weight and UFH treatment duration, likely contribute to the discordance between different strategies to establish an UFH therapeutic range. Conclusion: No consensus is reached between different strategies to define the UFH therapeutic range, which could result in relevant differences in UFH doses applied in patients. Clinicians and laboratory specialists should critically evaluate UFH monitoring protocols and be aware of their shortcomings.


1990 ◽  
Vol 63 (01) ◽  
pp. 016-023 ◽  
Author(s):  
A M H P van den Bessekaar ◽  
J Meeuwisse-Braun ◽  
R M Bertina

SummaryFive different APTT reagents, two amidolytic anti-ITa assays, one amidoiytic anti-Xa assay, and one coagulometric anti-Xa/ anti-IIa assay were used to assess the effect of heparin in patients treated for venous thromboembolic disease. Good correlations were observed between lug-transformed APYE> determined with the various reagents (correlation coefficients: 0.92-0.96).Nevertheless there were important differences in the slopes of the lines of relationship between the APTT reagents.Good correlations were observed between the anti-Xa and anti-IIa assay results (correlation coefficients: 0.92-0.97). However, the amidolytic anti-Xa activity was significantly higher (p <0.001) than the two amidolytic anti-IIa activities. Less good correlations were observed between the log-transformed APTTs and the anti-Xa or anti-IIa activities (correlation coefficients: 0.64-0.78). The correlations were improved by transforming the APTT into APTT-ratio, i.e. the ratio of the patient’s APTT to the same patient’s APTT after removal of heparin from the plasma sample by means of ECTEOLA-cellulose treatment. The correlation coefficients of log (AFTT-ratio) with anti-Xa or anti-IIa ranged from 0.76 to 0.87.For both APTT and amidolytic heparin assay, the response to in vitro heparin was different from the response to ex vivo heparin.Therefore, equivalent therapeutic ranges should be assessed by using ex vivo samples rather than in vitro heparin. Because of the response differences between the APTT reagents, it is not adequate to define a therapeutic range for heparin therapy without specification of the reagent.


1994 ◽  
Vol 72 (05) ◽  
pp. 685-692 ◽  
Author(s):  
Michael T Nurmohamed ◽  
René J Berckmans ◽  
Willy M Morriën-Salomons ◽  
Fenny Berends ◽  
Daan W Hommes ◽  
...  

SummaryBackground. Recombinant hirudin (RH) is a new anticoagulant for prophylaxis and treatment of venous and arterial thrombosis. To which extent the activated partial thromboplastin time (APTT) is suitable for monitoring of RH has not been properly evaluated. Recently, a capillary whole blood device was developed for bed-side monitoring of the APTT and it was demonstrated that this device was suitable to monitor heparin therapy. However, monitoring of RH was not evaluated.Study Objectives. To evaluate in vitro and ex vivo the responsiveness and reproducibility for hirudin monitoring of the whole blood monitor and of plasma APTT assays, which were performed with several reagents and two conventional coagulometers.Results. Large interindividual differences in hirudin responsiveness were noted in both the in vitro and the ex vivo experiments. The relationship between the APTT, expressed as clotting time or ratio of initial and prolonged APTT, and the hirudin concentration was nonlinear. A 1.5-fold increase of the clotting times was obtained at 150-200 ng/ml plasma. However, only a 2-fold increase was obtained at hirudin levels varying from 300 ng to more than 750 ng RH/ml plasma regardless of the assays. The relationship linearized upon logarithmic conversion of the ratio and the hirudin concentration. Disregarding the interindividual differences, and presuming full linearity of the relationship, all combinations were equally responsive to hirudin.Conclusions. All assays were equally responsive to hirudin. Levels up to 300 ng/ml plasma can be reliably estimated with each assay. The manual device may be preferable in situations where rapid availability of test results is necessary.


2013 ◽  
Vol 20 (7) ◽  
pp. 723-728 ◽  
Author(s):  
Je Sang Kim ◽  
Hyun Jong Lee ◽  
Ji Dong Sung ◽  
Hee-Jin Kim ◽  
Soo-Youn Lee ◽  
...  