scholarly journals Diversion Principle Reduces Skin Flora Contamination Rates in a Community Hospital

2019 ◽  
Vol 144 (2) ◽  
pp. 215-220 ◽  
Author(s):  
Sadia Syed ◽  
David T. Liss ◽  
Chris O. Costas ◽  
Janis M. Atkinson

Context.— Blood culture contamination is a common problem faced by medical centers and leads to significant cost. A possible method to reduce contamination is to discard the initial aliquot of blood, which contains skin and bacteria. Objective.— To determine whether the rate of contaminant blood cultures could be reduced by changing the order of draw to divert the first 7 mL to a gold- or green-top tube. Design.— A preintervention and postintervention study was conducted. During the 18-month intervention phase (September 2015–February 2017), all nurses in the emergency department and inpatient floor phlebotomists collected blood cultures by drawing the first 7 mL of blood into a gold- or green-top tube followed by drawing blood for blood culture bottles. The 18 months immediately preceding the study period (February 2014–July 2015) were used for comparison. Results.— There was an overall statistically significant decrease in contamination rate from 2.46% in the prediversion protocol group to 1.70% in the postdiversion protocol group (P < .001). Emergency department drawn cultures and inpatient cultures showed significant decrease in contamination rates between the preprotocol and postprotocol groups, 2.92% versus 1.95% (P < .001) for emergency department, and 1.82% versus 1.31% (P = .03) for inpatient. We noted less month-to-month variation during the study period compared with the preintervention period. Conclusions.— By using this simple diversion method, we were able to improve blood culture contamination rates for our emergency department and inpatients while incurring no added cost to the procedure.

2021 ◽  
Vol 14 ◽  
pp. 73-76
Author(s):  
Blake Buzard ◽  
Patrick Evans ◽  
Todd Schroeder

Introduction: Blood cultures are the gold standard for identifying bloodstream infections. The Clinical and Laboratory Standards Institute recommends a blood culture contamination rate of <3%. Contamination can lead to misdiagnosis, increased length of stay and hospital costs, unnecessary testing and antibiotic use. These reasons led to the development of initial specimen diversion devices (ISDD). The purpose of this study is to evaluate the impact of an initial specimen diversion device on rates of blood culture contamination in the emergency department.  Methods: This was a retrospective, multi-site study including patients who had blood cultures drawn in an emergency department. February 2018 to April 2018, when an ISDD was not utilized, was compared with June 2019 to August 2019, a period where an ISDD was being used. The primary outcome was total blood culture contamination. Secondary outcomes were total hospital cost, hospital and intensive care unit length of stay, vancomycin days of use, vancomycin serum concentrations obtained, and repeat blood cultures obtained.  Results: A statistically significant difference was found in blood culture contamination rates in the Pre-ISDD group vs the ISDD group (7.47% vs 2.59%, p<0.001). None of the secondary endpoints showed a statistically significant difference. Conclusions: Implementation of an ISDD reduces blood culture contamination in a statistically significant manner. However, we were unable to capture any statistically significant differences in the secondary outcomes.


2021 ◽  
Vol 8 (Supplement_1) ◽  
pp. S432-S432
Author(s):  
Alexander G Hosse

Abstract Background Blood cultures are the gold standard for diagnosing bloodstream infections and a vital part of the work-up in systemic infections. However, contamination of blood cultures represents a significant burden on patients and the healthcare system with increased hospital length of stay, unnecessary antibiotics, and financial cost. The data discussed here offer insight into blood culture contamination rates before and through the COVID-19 pandemic at a community hospital and the processes that were affected by the pandemic. Methods Blood culture contaminations were determined by using the number of sets of blood cultures with growth and the presence of an organism from the National Healthcare Safety Network's (NHSN) commensal organism. Contamination rates were evaluated by status as a standard unit or a COVID-19 isolation unit in either the emergency department (ED) or inpatient floor units. The identified four groups had different processes for drawing blood cultures, particularly in terms of training of staff in use of diversion devices. The electronic medical record was used to track contaminations and the use of diversion devices in the different units. Results The inpatient COVID units were consistently elevated above the other units and the institutional contaminant goal of 2.25%, ranging from 9.6% to 13.3% from 4/2020-9/2020. Those units were the primary driver of the increase in overall contamination rates. COVID ED nursing staff (that had previously undergone training in the use of diversion devices) used diversion devices to draw 51 of 133 (38.3%) cultures compared to only 15 of 84 (17.9%) on the COVID inpatient units. Figure 1. Comparison of contamination rates in the ED vs the inpatient units from all campuses from September 2019 through September 2020. The blue line represents the hospital goal of 2.25% contamination rate. Solid lines represent total contamination rates including COVID isolation units whereas dotted lines represent units excluding COVID isolation units. Figure 2. Comparison of the non-COVID vs COVID isolation units in the emergency department and inpatient units. The red line represents the hospital goal of less than 2.25% for blood culture contamination rate. Table of Contaminants vs. Total Collected Blood Cultures in Each Unit by Month Figure 3. Raw data from Figure 2. Total blood culture contaminations from each unit by month compared to total blood culture collections from each unit by month. Conclusion Evaluation revealed that nursing staff with less training in blood culture collection, particularly the use of diversion devices, were the primary staff collecting blood cultures in the inpatient COVID units. The difference in training is felt to be the primary driver of the increase in contaminants in the inpatient COVID units. The marked increase in contaminations highlights the difficulties of maintaining quality control processes during an evolving pandemic and the importance of ongoing efforts to improve the quality of care. These findings demonstrate the importance of training and routine use of procedures to reduce contaminations even during. Disclosures All Authors: No reported disclosures


2021 ◽  
Vol 156 (Supplement_1) ◽  
pp. S127-S127
Author(s):  
R Bedi ◽  
J Atkinson

Abstract Introduction/Objective Blood cultures are commonly obtained to evaluate the presence of bacteria or fungal infection in a patient’s bloodstream. The presence of living microorganisms circulating in the bloodstream is of substantial prognostic and diagnostic importance. A positive blood culture indicates a reason for the patient’s illness and provides the etiological agent for antimicrobial therapy. Collection of blood culture is an exact process that requires time, the proper order of draw, and following of correct protocol. The busy Emergency department that requires multiple demands for nurse’s time, turnover of staff, rushing from one task to another can result in the improper collection and false-positive blood cultures. The national benchmark is set at 3% by the American Society of Clinical Microbiology (ASM) and The Clinical and Laboratory Standard Institute (CLSI). False-positive blood culture results in increased length of stay and unnecessary antimicrobial therapy, resulting in an increased cost burden to the hospital of about $5000 per patient. Methods/Case Report At our 150-bed community hospital, 26 beds Emergency Department, we have come a long way in reduction of our blood culture contamination rates from upwards of 4% to less than 2%, far lower than the national benchmark. Results (if a Case Study enter NA) NA Conclusion There are multiple devices available from various manufacturers claiming to reduce blood culture contamination. These devices do reduce blood culture (BC) contamination but at an added cost of the device. The rate of BC can be reduced and less than 3% is achievable by materials available in the laboratory. We have achieved this by providing training to every new staff by demonstration and direct observation, providing everything required for collection in a kit, using proper technique, the inclusion of diversion method that involves the aseptic collection of a clear tube before collecting blood cultures, and following up monthly on any false positive blood cultures.


2021 ◽  
Author(s):  
Koshi Ota ◽  
Daisuke Nishioka ◽  
Yuri Ito ◽  
Emi Hamada ◽  
Naomi Mori ◽  
...  

Abstract Background: Blood cultures are indispensable for detecting life-threatening bacteremia. Little is known about associations between contamination rates and topical disinfectants for blood collection in adults.Objective: We sought to determine whether a change in topical disinfectants was associated with the rates of contaminated blood cultures in the emergency department of a single institution.Methods: This single-center, retrospective observational study of consecutive patients aged 20 years or older was conducted in the emergency department (ED) of a university hospital in Japan between August 1, 2018 and September 30, 2020. Pairs of blood samples were collected for aerobic and anaerobic culture from the patients in the ED. Physicians selected topical disinfectants according to their personal preference before September 1, 2019; alcohol/chlorhexidine gluconate (ACHX) was mandatory thereafter, unless the patient was allergic to alcohol. Regression discontinuity analysis was used to detect the effect of the mandatory usage of ACHX on rates of contaminated blood cultures.Results: We collected 2,141 blood culture samples from 1097 patients and found 164 (7.7%) potentially contaminated blood cultures. Among these, 445 (20.8%) were true bacteremia and 1,532 (71.6%) were true negatives. Puncture site disinfection was performed with ACHX for 1,345 (62.8%) cases and with povidone-iodine (PVI) for 767 (35.8%) cases. The regression discontinuity analysis showed that mandatory ACHX usage significantly reduced the blood culture contamination rate by 9.6% (95% confidence interval (CI): 5.0%–14.2%, P <0.001).Conclusion: Rates of contaminated blood cultures were significantly lower when ACHX was used as the topical disinfectant.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Koshi Ota ◽  
Daisuke Nishioka ◽  
Yuri Ito ◽  
Emi Hamada ◽  
Naomi Mori ◽  
...  

AbstractBlood cultures are indispensable for detecting life-threatening bacteremia. Little is known about associations between contamination rates and topical disinfectants for blood collection in adults. We sought to determine whether a change in topical disinfectants was associated with the rates of contaminated blood cultures in the emergency department of a single institution. This single-center, retrospective observational study of consecutive patients aged 20 years or older was conducted in the emergency department (ED) of a university hospital in Japan between August 1, 2018 and September 30, 2020. Pairs of blood samples were collected for aerobic and anaerobic culture from the patients in the ED. Physicians selected topical disinfectants according to their personal preference before September 1, 2019; alcohol/chlorhexidine gluconate (ACHX) was mandatory thereafter, unless the patient was allergic to alcohol. Regression discontinuity analysis was used to detect the effect of the mandatory usage of ACHX on rates of contaminated blood cultures. We collected 2141 blood culture samples from 1097 patients and found 164 (7.7%) potentially contaminated blood cultures. Among these, 445 (20.8%) were true bacteremia and 1532 (71.6%) were true negatives. Puncture site disinfection was performed with ACHX for 1345 (62.8%) cases and with povidone-iodine (PVI) for 767 (35.8%) cases. The regression discontinuity analysis showed that mandatory ACHX usage was significantly associated with lower rates of contaminated blood cultures by 9.6% (95% confidence interval (CI): 5.0%–14.2%, P < 0.001). Rates of contaminated blood cultures were significantly lower when ACHX was used as the topical disinfectant.


2020 ◽  
Vol 7 (Supplement_1) ◽  
pp. S187-S187
Author(s):  
Lucy S Tompkins ◽  
Alexandra Madison ◽  
Tammy Schaffner ◽  
Jenny Tran ◽  
Pablito Ang

Abstract Background Blood samples obtained via traditional venipuncture can become contaminated by superficial and deeply embedded skin flora. We evaluated the hospital-wide use of an initial-specimen diversion device (ISDD) designed to shunt these microorganisms away from the culture bottle to reduce blood culture contamination (BCC) and sequelae: false-positive central line-associated bloodstream infections (CLABSIs), repeat blood culture draws, inappropriate antibiotic usage, increased patient length-of-stay and misdiagnosis. The study aimed to show the proportion of blood cultures containing contaminants drawn by phlebotomy staff using the ISDD versus those drawn using traditional methods. Nursing staff continued to use traditional methods to draw blood cultures in the emergency department (ED) and from inpatients. Methods Over a four-month trial at Stanford Health Care (SHC), 4,462 blood cultures were drawn by phlebotomy staff using the ISDD (Steripath Gen2, Magnolia Medical Technologies) in the ED and from inpatients; 922 blood cultures were obtained by phlebotomy staff using standard methods. Additionally, 1,413 blood cultures were drawn by nursing staff using standard methods. The number of matched sets (2 bottles [aerobic/anaerobic] plus 2 bottles [aerobic/anaerobic], with total volume 40 ml) obtained through traditional methods and by the ISDD were recorded. Contaminants were defined by the National Healthcare Safety Network (NHSN). In addition, sets in which 1 out of 4 bottles contained vancomycin-resistant Enterococcus (VRE) or Candida sp. were also recorded, even though these are not considered contaminants by the NHSN. Results Of 4,462 blood cultures obtained using the ISDD there were zero contaminants found (BCC rate 0%) versus 29 contaminated sets using traditional methods (BCC rate 3.15%). Twenty-eight contaminants were observed from nursing staff blood culture draws (BCC rate 1.98%). Zero false-positive CLABSIs were associated with use of the ISDD for the trial period. No matched sets containing 1 of 4 bottles with VRE or Candida sp. were observed. Table Stanford Health Care blood culture collection methods and contamination events (March 15, 2019 - July 21, 2019) Conclusion The trial results encourage adoption of the ISDD as standard practice for blood culture at SHC. Disclosures All Authors: No reported disclosures


2021 ◽  
Vol 1 (S1) ◽  
pp. s36-s36
Author(s):  
Connie Schaefer

Background: Blood culture is a crucial diagnostic tool for healthcare systems, but false-positive results drain clinical resources, imperil patients with an increased length of stay (and associated hospital-acquired infection risk), and undermine global health initiatives when broad-spectrum antibiotics are administered unnecessarily. Considering emerging technologies that mitigate human error factors, we questioned historically acceptable rates of blood culture contamination, which prompted a need to promote and trial these technologies further. In a 3-month trial, 3 emergency departments in a midwestern healthcare system utilized an initial specimen diversion device (ISDD) to draw blood cultures to bring their blood culture contamination rate (4.4% prior to intervention) below the 3% benchmark recommended by the Clinical & Laboratory Standards Institute. Methods: All emergency department nursing staff received operational training on the ISDD for blood culture sample acquisition. From June through August 2019, 1,847 blood cultures were drawn via the ISDD, and 862 were drawn via the standard method. Results: In total, 16 contamination events occurred when utilizing the ISDD (0.9%) and 37 contamination events occurred when utilizing the standard method (4.3%). ISDD utilization resulted in an 80% reduction in blood culture contamination from the rate of 4.4% rate held prior to intervention. Conclusions: A midwestern healthcare system experienced a dramatic reduction in blood culture contamination across 3 emergency departments while pilot testing an ISDD, conserving laboratory and therapeutic resources while minimizing patient exposure to unnecessary risks and procedures. If the results obtained here were sustained and the ISDD utilized for all blood culture draws, nearly 400 contamination events could be avoided annually in this system. Reducing unnecessary antibiotic use in this manner will lower rates of associated adverse events such as acute kidney injury and allergic reaction, which are possible topics for further investigation. The COVID-19 pandemic has recently highlighted both the importance of keeping hospital beds available and the rampant carelessness with which broad-spectrum antibiotics are administered (escalating the threat posed by multidrug-resistant organisms). As more ambitious healthcare benchmarks become attainable, promoting and adhering to higher standards for patient care will be critical to furthering an antimicrobial stewardship agenda and to reducing treatment inequity in the field.Funding: NoDisclosures: None


Author(s):  
Dr. Pankaj Kumar Singh

Aims and objectives: To determine the risk factors of blood culture contamination done in ED and those done in the MHDU/MICU among patients admitted with medical illness. Material and Methods: This is a two months’ prospective observational study comparing blood culture contamination rate and risk factors associated with contamination between ED and MICU/MHDU. A total of 998 patients were included in the study who underwent blood culture in ED and MICU/MHDU. 570 in ED and 428 in MICU/MHDU were included after meeting exclusion and inclusion criteria. Results: Blood culture growths were higher in ED (19%). Most common growth was CoNS (4%). The overall contamination rate in this study was (4.8%) The contamination rate was lower in ED (4.4%) when compared to MICU/MHDU (5.4%).


Author(s):  
Katryn Paquette ◽  
David Sweet ◽  
Robert Stenstrom ◽  
Sarah N Stabler ◽  
Alexander Lawandi ◽  
...  

Abstract Background Sepsis is a leading cause of morbidity, mortality, and health care costs worldwide. Methods We conducted a multi-center, prospective cohort study evaluating the yield of blood cultures drawn before and after empiric antimicrobial administration among adults presenting to the emergency department with severe manifestations of sepsis (ClinicalTrials.gov: NCT01867905). Enrolled patients who had the requisite blood cultures drawn were followed for 90 days. We explored the independent association between blood culture positivity and its time to positivity in relation to 90-day mortality. Findings 325 participants were enrolled; 90-day mortality among the 315 subjects followed-up was 25·4% (80/315). Mortality was associated with age (mean age in those who died was 72·5 ±15·8 vs. 62·9 ±17·7 years among survivors, p&lt;0·0001), greater Charlson Comorbidity Index (2 (IQR 1,3) vs. 1 (IQR 0,3), p=0·008), dementia (13/80 (16·2%) vs. 18/235 (7·7%), p=0·03), cancer (27/80 (33·8%) vs. 47/235 (20·0%), p=0·015), positive qSOFA score (57/80 (71·2%) vs. 129/235 (54·9%), p=0·009), and normal white blood cell counts (25/80 (31·2%) vs. 42/235 (17·9%), p=0·02). The presence of bacteremia, persistent bacteremia after antimicrobial infusion, and shorter time to blood culture positivity were not associated with mortality. Neither the source of infection nor pathogen affected mortality. Interpretation Although severe sepsis is an inflammatory condition triggered by infection, its 90-day survival is not influenced by blood culture positivity nor its time to positivity. Funding Vancouver Coastal Health; St-Paul’s Hospital Foundation Emergency Department Support Fund; the Fonds de Recherche Santé – Québec (CPY); Intramural Research Program of the NIH, Clinical Center (AL); the Maricopa Medical Foundation


Sign in / Sign up

Export Citation Format

Share Document