A novel ecofriendly, cost effective mobile phase for hplc- simultaneous estimation and validation of paracetamol and diclofenac sodium in bulk and pharmaceutical formulation by rp-hplc using hydrotropic solution as mobile phase

2020 ◽  
Vol 10 (3) ◽  
pp. 163
Author(s):  
S. L. Remi ◽  
Joyamma Varkey ◽  
R. K. Maheshwari ◽  
A. Jayakumaran Nair
INDIAN DRUGS ◽  
2021 ◽  
Vol 58 (06) ◽  
pp. 49-59
Author(s):  
Hemant Kumar T ◽  
◽  
Gowri Sankar D ◽  

A simple, specific, accurate, precise and stability-indicating RP-HPLC method was developed and validated for the simultaneous estimation of metformin HCl and canagliflozin in pharmaceutical formulation. The method was developed using the Altima C8 column (150 ×4.6 mm, 0.5 μm) with a mobile phase consisting of acetonitrile and 0.1 % orthophosphoric acid in water (62:38 %V/V) with a flow rate of 1 mL/min. Detection was carried out at 254 nm using a PDA detector. The retention time for metformin HCl and canagliflozin was found to be 2.282 and 3.339 min, respectively. The proposed method was validated for linearity, range, accuracy, precision, robustness, LOD and LOQ. Linearity was observed over a concentration range 15-225 μg/mL for metformin HCl (r2 =0.9995) and 5-40 μg/mL for canagliflozin (r2 =0.9988). The % RSD for intraday and interday precision was found to be 0.13 and 0.20 for metformin HCl and 0.18 and 0.20 for canagliflozin. The LOD and LOQ were found to be 0.16 μg/mL and 0.54 μg/mL for metformin HCl and LOD and LOQ were found to be 0.05 and 0.21 μg/mL for canagliflozin. Metformin HCl and canagliflozin were subjected to stress conditions of degradation including acidic, alkaline, oxidative, thermal and photolysis.


2020 ◽  
Vol 10 (6) ◽  
pp. 120-132
Author(s):  
V. M. Bhalme ◽  
P. P. Jumade ◽  
Ram D Bawankar ◽  
D. S. Wanjari ◽  
D. R. Mundhada

Objective: Method development, validation & stability indicating studies for simultaneous estimation of Anti-Hypertensive drugs, Benidepine (BEN) and Metoprolol (MET) from pharmaceutical formulation by RP-HPLC. Methods: For present work, reverse phase chromatography was selected as its suggested use for ionic and moderate to non-polar compounds. Reverse phase chromatography is simple, suitable, better regarding efficiency, stability, and reproducibility. C18 packed column, a 100 X 2.1mm. ID column of 5.0 μm particle packing, was selected for separation of BEN and MET. Different solvent systems were tried and optimized in combinations as mobile phase. BEN (4 μg/ml) and MET (50 μg/ml) in 15mM ammonium formate-Methanol (15:85 v/v) was developed as it was showing good peak shapes and a significant amount of resolution. The mobile phase was flowed at 1.2 ml/min with detection of BEN analytes at 236 nm and MET analytes at 225 nm respectively. Result: Method development was done. Specificity, linearity, accuracy, precision, robustness, limit of detection and limit of quantitation were used to accomplish validation. The method was found linear from 32.5 – 500 µg.ml-1 for both BEN and MET individually. The percentage recovery of BEN when placed for period of 12 hours was found to 100% in 0.1N/M NaOH at 60˚C and Thermal (60˚C); 12 % degradation in 0.1N/M HCl at 60˚C; Oxidation (3-6% H2O2) at room temperature whereas for MET was 100 % in 0.1N/M NaOH, 0.1N/M HCl at 60˚C, at thermal (60˚C) as well as oxidation by 3-6% H2O2 at room temperature.  Conclusion: Developed analytical method for the simultaneous estimation of Benidipine (BED) and Metoprolol (MET) in both bulk and tablet formulation has obliged the ICH guidelines including, tailing factor (T), separation factors (α), theoretical plates (N), capacity factor (k’), resolution (R) and RSD (%). The validated stress degradation studies under thermal, oxidative, alkali and acid ascertained few degradation products for Benidipine whereas the Metoprolol was unaffected with forced degradation studies. Keywords: Benidipine, Metoprolol, Reverse-Phase High Performance Liquid Chromatography, Stability indicating method.


INDIAN DRUGS ◽  
2019 ◽  
Vol 56 (07) ◽  
pp. 59-68
Author(s):  
H Mahajan ◽  
S Savale ◽  
P Nerkar ◽  

The present study was aimed at developing a Reversed-Phase High-Performance Liquid Chromatography (RP-HPLC) method for simultaneous determination of curcumin (CRM) and gefitinib (GFT) in bulk, plasma and brain homogenate. hydrochlorothiazide was used as an internal standard (IS). A new simple, rapid, selective, precise and accurate RP-HPLC method has been developed. The separation was achieved by using C-18 column (Qualisil BDS C18, 250 mm x 4.6 mm I.D.) coupled with a guard column of silica, mobile phase consisted of acetonitrile: water with 0.1% formic acid (30:70 v/v). The flow rate was 0.2 ml/min and the drug was detected using PDA detector at the wavelength of 242 nm. The experimental conditions, including the diluting solvent, mobile phase composition, column saturation and flow rate, were optimised to provide high-resolution and reproducible peaks. The method was developed and tested for linearity range of 10-60 μg/mL for bulk analysis and 200-800 ng/mL for plasma and brain homogenate. The developed method was validated as per ICH guidelines, in terms of linearity, application of the proposed method to bulk sample, recovery, precision, repeatability, ruggedness, sensitivity (LOD and LOQ) and robustness and stability study (short and long-term stabilities, freeze/thaw stability, post-preparative). The low value of % RSD showed that the method was precise within the acceptance limit of 2%. The developed method was successfully applied for the analysis of the drug in bulk as well as various marketed formulation and drug in plasma and brain distribution studies.


Author(s):  
Krutika Patel ◽  
Sudheer Kumar Verriboina ◽  
S.G. Vasantharaju

A simple, accurate, specific and stability-indicating RP-HPLC method was developed for simultaneous determination of chlorzoxazone, diclofenac sodium and paracetamol, using C18 Vydac Monomeric 120A (250 × 4.6mm, 5μ) at 40ºC. The mobile phase contains a mixture of 20mM potassium dihydrogen phosphate buffer (pH 6.2 adjusted with potassium hydroxide) and acetonitrile (30:70 v/v). The flow rate was 1ml/min and detection was carried out at 275nm using PDA detector. The retention time of paracetamol, chlorzoxazone and diclofenac sodium were 3.28mins, 13.27mins and 15.61mins respectively. The analytical curve was linear over a concentration range of 0.65- 6.5μg/ml for paracetamol, 1-10μg/ml for chlorzoxazone and 0.1-1μg/ml for diclofenac sodium. The drugs in bulk and tablet were subjected to acid and alkali hydrolysis, oxidation, thermal and photolytic degradation. This method can be successfully employed for simultaneous quantitative analysis of Chlorzoxazone, Diclofenac sodium and Paracetamol in bulk drug and tablet formulation.


2020 ◽  
Vol 12 (3) ◽  
pp. 155-165
Author(s):  
Pooja Eknathji Waware ◽  
Anuja Dattatriayji Jolhe ◽  
Swati Rajendra Lilhare ◽  
Prasad Prakash Jumade ◽  
Dharmendra Ramgopalji Mundhada

Author(s):  
Rama Rao Nadendla ◽  
Patchala Abhinandana

Aim: The main aim of the current study is to give best and simple method for the estimation of antiparkinsonian drugs named Carbidopa, levodopa and entacapone. Study Design:  Simultaneous estimation of Carbidopa, levodopa and entacapone was performed by using Quadrapumped (SHIMADZU Prominance-i, LC-2030C) RP-HPLC equipped with PDA detector. Place and Duration of Study: Chalapathi Drug Testing Laboratory, Chalapathi Institute Of Pharmaceutical Sciences, Lam, Guntur-522034, Andhra Pradesh, India during the period of August 2019 to February 2020. Methodology: The assets of the study can determined as the process of qualification and quantification was done on SHIMADZU Prominance-i, LC-2030C system equipped with Phenomenex ODS (150 x 4.6 mm, 5μm) column and mobile phase was optimized using combination of acetonitrile and 0.1% ortho phosphoric acid in the ration of 50:50 v/v at a flow rate 1.0 ml/min. The wavelength was set as 270nm at ambient temperature by injecting 20µl of solution and the run time was fixed for 5 min. Results: Calibration plot shown best regression over the concentration range of 5-160 µg/ml of Carbidopa, Levodopa and Entacapone standard solutions. The LOD and LOQ were found to be 0.85 and 2.54 µg/ml for Entacapone, 0.24 and 0.71 µg/ml for Levodopa, 0.14 and 0.43 µg/ml for Carbidopa respectively. The accuracy of the proposed method was determined by performing recovery studies and was found to be between 98-102%. The repeatability testing for both sample and standard solutions was found as %RSD<2.0% which is within the acceptable limits showing that the method is precise as well. The proposed method was successfully applied for the marketed formulations of Carbidopa, Levodopa and Entacapone tablets. In addition the main feature of proposed method is economic and eco-friendly with less retention time around 5.0 min. Conclusion: Including all the optimized method parameters and statistical results given it can be concluded as a new, simple, sensitive, precise and accurate economical analytical method was developed and validated by RP-HPLC for the detection and quantification of Carbidopa, Levodopa and Entacapone which can be applied to the marketed formulation where there are no official compendial methods reported for this particular combination. The high sensitivity (LOD), mobile phase utilized and run time (=5) can be determined as an important features for this proposal.


Author(s):  
K. S Ashutosh ◽  
D. Manidipa ◽  
R. J. V. L. N. Seshagiri ◽  
S. D. Gowri

The RP-HPLC separation was carried out by reverse phase chromatography on a Symmetry C18 (4.6 x 150 mm, 3.5 μm, make: XTerra) with a mobile phase composed of sodium dihydrogen ortho phosphate [pH 2.5] and acetonitrile in the ratio of 30:70 v/v in an isocratic mode at a flow rate of 1.2 mL/min. The run time was maintained for 8.0 min. The detection was monitored at 236 nm. The accuracy was calculated in human plasma and the % recovery was found 99.80 - 99.85 for famotidine and 99.56 -99.85.5 for ibuprofen and reproducibility was found to be satisfactory. The calibration curve for famotidine in human plasma was linear over 3.32 to 6.65 μg/mL and 100- 200 μg/mL for ibuprofen in human plasma respectively. The inter-day and intra-day precision in human plasma was found within limits. The proposed method has adequate sensitivity, reproducibility, and specificity for the determination of famotidine and ibuprofen in plasma. The LLOQ obtained by the proposed method in human plasma were 1.24 and 5.0 μg/mL for famotidine and ibuprofen respectively. The proposed method is simple, fast, accurate, and precise for the quantification of famotidine and ibuprofen in plasma as per the ICH guidelines.Kathmandu University Journal of Science, Engineering and TechnologyVol. 12, No. I, June, 2016, Page: 34-48


Sign in / Sign up

Export Citation Format

Share Document