scholarly journals Impact of temperature variation on energy consumption and productivity of the occupants in office buildings

Energetika ◽  
2012 ◽  
Vol 58 (3) ◽  
Author(s):  
Rokas Valančius ◽  
Andrius Jurelionis
2007 ◽  
Vol 72 (615) ◽  
pp. 81-87
Author(s):  
Kazuhiko SAKAMOTO ◽  
Saburo MURAKAWA ◽  
Michimasa SHINOHARA ◽  
Daisaku NISHINA ◽  
Yoshiyuki UEMURA

Energies ◽  
2021 ◽  
Vol 14 (8) ◽  
pp. 2064
Author(s):  
Jin-Hee Kim ◽  
Seong-Koo Son ◽  
Gyeong-Seok Choi ◽  
Young-Tag Kim ◽  
Sung-Bum Kim ◽  
...  

Recently, there have been significant concerns regarding excessive energy use in office buildings with a large window-to-wall ratio (WWR) because of the curtain wall structure. However, prior research has confirmed that the impact of the window area on energy consumption varies depending on building size. A newly proposed window-to-floor ratio (WFR) correlates better with energy consumption in the building. In this paper, we derived the correlation by analyzing a simulation using EnergyPlus, and the results are as follows. In the case of small buildings, the results of this study showed that the WWR and energy requirement increase proportionally, and the smaller the size is, the higher the energy sensitivity will be. However, results also confirmed that this correlation was not established for buildings approximately 3600 m2 or larger. Nevertheless, from analyzing the correlation between the WFR and the energy requirements, it could be deduced that energy required increased proportionally when the WFR was 0.1 or higher. On the other hand, the correlation between WWR, U-value, solar heat gain coefficient (SHGC), and material property values of windows had little effect on energy when the WWR was 20%, and the highest effect was seen at a WWR of 100%. Further, with an SHGC below 0.3, the energy requirement decreased with an increasing WWR, regardless of U-value. In addition, we confirmed the need for in-depth research on the impact of the windows’ U-value, SHGC, and WWR, and this will be verified through future studies. In future studies on window performance, U-value, SHGC, visible light transmittance (VLT), wall U-value as sensitivity variables, and correlation between WFR and building size will be examined.


Energies ◽  
2019 ◽  
Vol 12 (22) ◽  
pp. 4326 ◽  
Author(s):  
Simplice Igor Noubissie Tientcheu ◽  
Shyama P. Chowdhury ◽  
Thomas O. Olwal

The increasing demand to reduce the high consumption of end-use energy in office buildings framed the objective of this work, which was to design an intelligent system management that could be utilized to minimize office buildings’ energy consumption from the national electricity grid. Heating, Ventilation and Air Conditioning (HVAC) and lighting are the two main consumers of electricity in office buildings. Advanced automation and control systems for buildings and their components have been developed by researchers to achieve low energy consumption in office buildings without considering integrating the load consumed and the Photovoltaic system (PV) input to the controller. This study investigated the use of PV to power the HVAC and lighting equipped with a suitable control strategy to improve energy saving within a building, especially in office buildings where there are reports of high misuse of electricity. The intelligent system was modelled using occupant activities, weather condition changes, load consumed and PV energy changes, as input to the control system of lighting and HVAC. The model was verified and tested using specialized simulation tools (Simulink®) and was subsequently used to investigate the impact of an integrated system on energy consumption, based on three scenarios. In addition, the direct impact on reduced energy cost was also analysed. The first scenario was tested in simulation of four offices building in a civil building in South Africa of a single occupant’s activities, weather conditions, temperature and the simulation resulted in savings of HVAC energy and lighting energy of 13% and 29%, respectively. In the second scenario, the four offices were tested in simulation due to the loads’ management plus temperature and occupancy and it resulted in a saving of 20% of HVAC energy and 29% of lighting electrical energy. The third scenario, which tested integrating PV energy (thus, the approach utilized) with the above-mentioned scenarios, resulted in, respectively, 64% and 73% of HVAC energy and lighting electrical energy saved. This saving was greater than that of the first two scenarios. The results of the system developed demonstrated that the loads’ control and the PV integration combined with the occupancy, weather and temperature control, could lead to a significant saving of energy within office buildings.


2019 ◽  
Vol 9 (5) ◽  
pp. 858 ◽  
Author(s):  
Yu Dong ◽  
Xue Cui ◽  
Xunzhi Yin ◽  
Yang Chen ◽  
Haibo Guo

This research evaluates the operational heating and cooling energy consumption of cross-laminated timber (CLT) office buildings in China. The evaluations involve a comparison of the energy consumption of a reference RC structure and CLT system office buildings. Computational simulation results are based on IES-VE 2019 and show that the estimated heating energy saving ratio of CLT buildings in Harbin, Beijing, Shanghai, and Kunming to the reference structure are 11.97%, 22.11%, 30.94%, and 23.30% respectively. However, the CLT buildings consume more energy for cooling in the summer. The results of the research show significantly higher heating energy reductions for CLT buildings in the Cold Region and Severe Cold Regions of China. Thus, the application of the CLT system is better suited to northern China than southern China. The results of the research can be used in further assessment of the use of CLT systems in different climatic regions in China.


Sign in / Sign up

Export Citation Format

Share Document