scholarly journals Preoperative cervical sagittal alignment parameters and their impacts on myelopathy in patients with cervical spondylotic myelopathy: a retrospective study

PeerJ ◽  
2017 ◽  
Vol 5 ◽  
pp. e4027 ◽  
Author(s):  
Wei Yuan ◽  
Yue Zhu ◽  
Haitao Zhu ◽  
Cui Cui ◽  
Lei Pei ◽  
...  

Background Cervical sagittal alignment plays an important role in the pathogenesis of cervical spondylotic myelopathy (CSM), but there are limited studies on the cervical sagittal parameters in CSM patients and their correlations with myelopathy. The aim of this study is to investigate the correlations among the preoperative cervical sagittal alignment parameters and their correlations with the development of myelopathy in patients with CSM. Methods We retrospectively collected 212 patients with CSM who underwent surgical interventions. Gender, age, modified Japanese Orthopedic Association score (mJOA), cervical lordosis (CL), C2–C7 sagittal vertical axis (C2–C7 SVA), T1 slope (T1S), neck tilt (NT) and thoracic inlet angle (TIA) were collected before operation. Interobserver and intraobserver reliability were calculated for all measurements (intraclass correlation coefficient, ICC). Data were analyzed with Pearson and Spearman correlation tests and multiple linear regression analysis. Results A total of 212 patients with CSM were included in this study (male: 136, female: 76) with an average age of 54.5 ± 10.1 years old. Intraobserver and interobserver reliability for all included radiographic parameters presented good to excellent agreement (ICC > 0.7). No significant differences in demographic and radiological parameters have been observed between males and females (P > 0.05). We found statistically significant correlations among the following parameters: age with CL (r = 0.135, P = 0.049), age with T1S (r = 0.222, P = 0.001), CL with T1S (r = 0.291, P < 0.001), CL with C2-C7 SVA (r =  − 0.395, P < 0.001), mJOA with age (r =  − 0.274, P < 0.001), mJOA with C2–C7 SVA (r =  − 0.219, P < 0.001) and mJOA with T1S(r =  − 0.171, p = 0.013). Linear regression analysis showed that C2–C7 SVA was the predictor of CL (adjusted R2 = 0.152, P < 0.001) and multiple linear regression showed that age combined with C2–C7 SVA was a sensitive predictor of mJOA (adjusted R2 = 0.106, P < 0.001). Discussion There were significant correlations among certain preoperative cervical sagittal parameters in CSM patients. CL was the only predictor of C2–C7 SVA. Age combined with C2–C7 SVA could predict the severity of myelopathy.

BMC Surgery ◽  
2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Zheng Wang ◽  
Jia-Xin Xu ◽  
Zhen Liu ◽  
Ruo-Yu Li ◽  
Zhi-Wei Wang ◽  
...  

Abstract Background To explore the relationship between spino cranial angle (SCA) and loss of cervical lordosis (LOCL), and to determine whether SCA has the ability to predict LOCL for patients with cervical myelopathy. Methods A total of 68 consecutive patients with cervical myelopathy who received laminoplasty (LAMP) were selected to the current study. C2–C7 lordosis was defined as a representation of the cervical alignment. Alignment change > 0° was considered LOCL. Multiple linear regression analysis was applied to evaluate the association between LOCL and various sagittal parameters at preoperative, such as SCA, CL, T1s and cSVA. Linear regression analysis was applied to evaluate the relationships between LOCL and preoperative SCA in each subgroup. Results Patients were assigned to three groups depending on the quartile of preoperative SCA. The first quarter of patients were defined as the low SCA group, the last quarter were defined as the high SCA group and the middle half were defined as the middle SCA group. There was no statistically significant difference in age, sex and the type of OPLL among the three groups. Patients in the low SCA group showed more cervical lordosis before surgery and more LOCL after LAMP (p < 0.001). After linear regression analysis for SCA and LOCL, preoperative SCA was negatively correlated with LOCL in the low SCA group (r = − 0.857, p < 0.001) and high SCA group (r = − 0.515, p = 0.034). However, there was no significant correlation between preoperative SCA and LOCL in the middle SCA group (r = 0.027, p = 0.881). Conclusions Patients with lower SCA had more lordosis preoperatively and performed more LOCL after LAMP at 2 years of follow-up. Both too high or low preoperative SCA were negatively correlated with the degree of LOCL, while when the SCA fluctuates in a suitable range, it is easier to compensate for the changes of cervical sagittal alignment.


Author(s):  
Muhammad Rois Rois ◽  
Manarotul Fatati Fatati ◽  
Winda Ihda Magfiroh

This study aims to determine the effect of Inflation, Exchange Rate and Composite Stock Price Index (IHSG) to Return of PT Nikko Securities Indonesia Stock Fund period 2014-2017. The study used secondary data obtained through documentation in the form of PT Nikko Securities Indonesia Monthly Net Asset (NAB) report. Data analysis is used with quantitative analysis, multiple linear regression analysis using eviews 9. Population and sample in this research are PT Nikko Securities Indonesia. The result of multiple linear regression analysis was the coefficient of determination (R2) showed the result of 0.123819 or 12%. This means that the Inflation, Exchange Rate and Composite Stock Price Index (IHSG) variables can influence the return of PT Nikko Securities Indonesia's equity fund of 12% and 88% is influenced by other variables. Based on the result of the research, the variables of inflation and exchange rate have a negative and significant effect toward the return of PT Nikko Securities Indonesia's equity fund. While the variable of Composite Stock Price Index (IHSG) has a negative but not significant effect toward Return of Equity Fund of PT Nikko Securities Indonesia


2021 ◽  
Vol 15 ◽  
Author(s):  
Amuthalakshmi Sivaperuman ◽  
Ramalakshmi Natarajan ◽  
Manimegalai P ◽  
Arunkumar Subramani ◽  
Puratchikody Ayarivan

Background: Carboxylesterase Notum is a negative regulator of Wnt signaling. Notum carboxylesterase is a carboxylic ester hydrolase enzyme that functions as a negative feedback regulator of Wnt proteins by depalmitoylation reaction. It is of great importance to understand the pathway of Wnt regulation because, conversely, misregulation of Wnt signaling is a telltale sign of cancer and other degenerative diseases. The Wnt inhibition is important in the control of colorectal cancer. Objective: In the present study, we carried out a QSAR analysis of a series of reported compounds with carboxylesterase Notum inhibitory activity using multiple regression analysis. A series of 83 compound datasets of pyrrole derivatives with carboxy Notum inhibitory values were taken from the reported literature. Methods: The study was performed by conducting multiple linear regression analysis followed by validation of the model. The multiple linear regression (MLR) models with the highest coefficients of correlation (R2) and explained variance in leave-one-out (Q2 LOO) prediction and leave-many-out (Q2 LMO) were selected for the whole dataset. The developed models were subjected to internal and external validation. The reliability of the predicted model was checked by plotting the Williams plot. The docking methodology was performed using Autodock 4 for the designed compounds to study the interaction between the ligand and the receptor. Results: The best model generated exhibited an r2 value of 0.7413, Q2LOO =0.6379, Q2LMO =0.6368. Novel compounds of phenyl pyrrolidine were designed based on generated QSAR equations. The carboxylesterase Notum inhibitory activity was predicted using the QSAR equations. The docking studies were carried out for designed compounds using Autodock against Carboxylesterase Notum esterase. Conclusion: From the results, the designed compounds were found to inhibit Notum Carboxylase. Thus, the study led to the development of a novel lead compound for Carboxylesterase Notum.


2017 ◽  
Vol 44 (4) ◽  
pp. 1537-1544 ◽  
Author(s):  
Yu-qing Huang ◽  
Jie Li ◽  
Ji-yan Chen ◽  
Ying-ling Zhou ◽  
An-ping Cai ◽  
...  

Background/Aims: Although it is widely acknowledged that atherosclerosis is mainly a chronic inflammatory process, in which both miR-29b and interleukin-6 (IL-6) play multifaceted roles, the association between miR-29b and IL-6 remains unknown. The aim of the present study was to explore the relationship between miR-29b and IL-6 and to test whether circulating levels of miR-29b and IL-6 could predict atherosclerosis. Methods: A total of 170 participants were divided into two groups according to carotid intima-media thickness (CIMT): study group (CIMT ≥ 0.9mm) and control group (CIMT < 0.9mm). Levels of circulating miR-29b and IL-6 were measured by quantitative real-time polymerase chain reaction (qRT-PCR) and enzyme-linked immunosorbent assay (ELISA), respectively. The association of miR-29b and IL-6 levels with CIMT was assessed using Spearman correlation analysis and multiple linear regression analysis. Results: The study group showed higher miR-29b levels (31.61 ± 3.05 vs. 27.91 ± 1.71 Ct, p < 0.001) and IL-6 levels (3.40 ± 0.67 vs. 2.99 ± 0.37 pg/ml, p < 0.001), compared with the control group. CIMT was positively correlated with miR-29b (r = 0.587, p < 0.001) and IL-6 (r = 0.410, p < 0.001), and miR-29b levels were also correlated with IL-6 (r = 0.242, p = 0.001). Multiple linear regression analysis also showed that CIMT was positively correlated with miR-29b and IL-6. After adjustment for age, body mass index, systolic blood pressure, total cholesterol and C-reactive protein, CIMT was still closely correlated with miR-29b and IL-6. The combination of miR-29b and IL-6 (AUC = 0.901, p < 0.001) offered a better predictive index for atherosclerosis than either miR-29b (AUC = 0.867, p < 0.001) or IL-6 (AUC = 0.747, p < 0.001) alone. Conclusion: Circulating levels of miR-29b and IL-6 may be independently correlated with subclinical atherosclerosis, and may serve as novel biomarkers for the identification of atherosclerosis.


2017 ◽  
Vol 27 (5) ◽  
pp. 528-533 ◽  
Author(s):  
Jian Guan ◽  
Chad D. Cole ◽  
Meic H. Schmidt ◽  
Andrew T. Dailey

OBJECTIVEBlood loss during surgery for thoracolumbar scoliosis often requires blood product transfusion. Rotational thromboelastometry (ROTEM) has enabled the more targeted treatment of coagulopathy, but its use in deformity surgery has received limited study. The authors investigated whether the use of ROTEM reduces transfusion requirements in this case-control study of thoracolumbar deformity surgery.METHODSData were prospectively collected on all patients who received ROTEM-guided blood product management during long-segment (≥ 7 levels) posterior thoracolumbar fusion procedures at a single institution from April 2015 to February 2016. Patients were matched with a group of historical controls who did not receive ROTEM-guided therapy according to age, fusion segments, number of osteotomies, and number of interbody fusion levels. Demographic, intraoperative, and postoperative transfusion requirements were collected on all patients. Univariate analysis of ROTEM status and multiple linear regression analysis of the factors associated with total in-hospital transfusion volume were performed, with p < 0.05 considered to indicate statistical significance.RESULTSFifteen patients who received ROTEM-guided therapy were identified and matched with 15 non-ROTEM controls. The mean number of fusion levels was 11 among all patients, with no significant differences between groups in terms of fusion levels, osteotomy levels, interbody fusion levels, or other demographic factors. Patients in the non-ROTEM group required significantly more total blood products during their hospitalization than patients in the ROTEM group (8.5 ± 4.2 units vs 3.71 ± 2.8 units; p = 0.001). Multiple linear regression analysis showed that the use of ROTEM (p = 0.016) and a lower number of fused levels (p = 0.022) were associated with lower in-hospital transfusion volumes.CONCLUSIONSROTEM use during thoracolumbar deformity correction is associated with lower transfusion requirements. Further investigation will better define the role of ROTEM in transfusion during deformity surgery.


2020 ◽  
Vol 1 (02) ◽  
pp. 133-140
Author(s):  
Meli Andriyani ◽  
Riski Ardianto

The bank as a service company places great importance on satisfaction through services and products. The purpose of this study was to determine the effect of service quality and product quality on customer satisfaction. The research was conducted by distributing questionnaires to 100 respondents, namely bank customers who live and have bank accounts in the Cibubur area. The research data were analyzed using multiple linear regression analysis. The study found that service quality did not affect customer satisfaction, while product quality had a positive effect on customer satisfaction.


Sign in / Sign up

Export Citation Format

Share Document